Flow injection spectrophotometric determination of tetracycline in a pharmaceutical preparation by complexation with aluminium(III)

A rapid flow injection (FI) spectrophotometric procedure for tetracycline determination is described. It is based on the injection of a 100 μl sample solution containing tetracycline into merged streams of aluminium(III) chloride (0.01 mol l-1) and Tris-buffer in the presence of KCl (0.06 mol l-1),...

Full description

Saved in:
Bibliographic Details
Main Authors: Saisunee Liawruangrath, Boonsom Liawruangrath, Surasak Watanesk, Wirat Ruengsitagoon
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=30744437693&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/61594
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-61594
record_format dspace
spelling th-cmuir.6653943832-615942018-09-11T08:55:44Z Flow injection spectrophotometric determination of tetracycline in a pharmaceutical preparation by complexation with aluminium(III) Saisunee Liawruangrath Boonsom Liawruangrath Surasak Watanesk Wirat Ruengsitagoon Chemistry A rapid flow injection (FI) spectrophotometric procedure for tetracycline determination is described. It is based on the injection of a 100 μl sample solution containing tetracycline into merged streams of aluminium(III) chloride (0.01 mol l-1) and Tris-buffer in the presence of KCl (0.06 mol l-1), pH 7.0, with the same optimum flow rate of 3.2 ml min -1. A yellow Al(III)-tetracycline complex was monitored at 376 nm. The flow injection system and the experimental conditions were optimized by means of the univariate method. The procedure was applied to the determination of tetracycline in pharmaceutical preparations with a high sampling rate of at least 165 h-1. A high precision with a relative standard deviation was obtained less than 0.72 and 0.30% of 5.0 and 10 μg ml-1 (n = 11), respectively. The detection limit (3σ) and the quantification limit (10σ) were 0.07 and 0.72 mg l-1, respectively. There were no interference effects from traditional excipients in the dosage forms when the method was applied to pharmaceutical preparations. The matrix effect could be reduced by the standard addition method. 2006 © The Japan Society for Analytical Chemistry. 2018-09-11T08:55:43Z 2018-09-11T08:55:43Z 2006-01-01 Journal 09106340 2-s2.0-30744437693 10.2116/analsci.22.15 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=30744437693&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/61594
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Chemistry
spellingShingle Chemistry
Saisunee Liawruangrath
Boonsom Liawruangrath
Surasak Watanesk
Wirat Ruengsitagoon
Flow injection spectrophotometric determination of tetracycline in a pharmaceutical preparation by complexation with aluminium(III)
description A rapid flow injection (FI) spectrophotometric procedure for tetracycline determination is described. It is based on the injection of a 100 μl sample solution containing tetracycline into merged streams of aluminium(III) chloride (0.01 mol l-1) and Tris-buffer in the presence of KCl (0.06 mol l-1), pH 7.0, with the same optimum flow rate of 3.2 ml min -1. A yellow Al(III)-tetracycline complex was monitored at 376 nm. The flow injection system and the experimental conditions were optimized by means of the univariate method. The procedure was applied to the determination of tetracycline in pharmaceutical preparations with a high sampling rate of at least 165 h-1. A high precision with a relative standard deviation was obtained less than 0.72 and 0.30% of 5.0 and 10 μg ml-1 (n = 11), respectively. The detection limit (3σ) and the quantification limit (10σ) were 0.07 and 0.72 mg l-1, respectively. There were no interference effects from traditional excipients in the dosage forms when the method was applied to pharmaceutical preparations. The matrix effect could be reduced by the standard addition method. 2006 © The Japan Society for Analytical Chemistry.
format Journal
author Saisunee Liawruangrath
Boonsom Liawruangrath
Surasak Watanesk
Wirat Ruengsitagoon
author_facet Saisunee Liawruangrath
Boonsom Liawruangrath
Surasak Watanesk
Wirat Ruengsitagoon
author_sort Saisunee Liawruangrath
title Flow injection spectrophotometric determination of tetracycline in a pharmaceutical preparation by complexation with aluminium(III)
title_short Flow injection spectrophotometric determination of tetracycline in a pharmaceutical preparation by complexation with aluminium(III)
title_full Flow injection spectrophotometric determination of tetracycline in a pharmaceutical preparation by complexation with aluminium(III)
title_fullStr Flow injection spectrophotometric determination of tetracycline in a pharmaceutical preparation by complexation with aluminium(III)
title_full_unstemmed Flow injection spectrophotometric determination of tetracycline in a pharmaceutical preparation by complexation with aluminium(III)
title_sort flow injection spectrophotometric determination of tetracycline in a pharmaceutical preparation by complexation with aluminium(iii)
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=30744437693&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/61594
_version_ 1681425649837801472