Complications of loop electrosurgical excision procedure for cervical neoplasia: A prospective study

Objectives: To evaluate the complications following loop electrosurgical excision procedure (LEEP) for diagnosis and treatment of cervical neoplasia. Material and Method: Descriptive cross sectional study in patients with abnormal cervical cytology who underwent LEEP at Chiang Mai University Hospita...

Full description

Saved in:
Bibliographic Details
Main Authors: Chumnan Kietpeerakool, Jatupol Srisomboon, Apichart Khobjai, Aunchalee Chandacham, Umpawan Tucksinsook
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33646794446&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/61870
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-61870
record_format dspace
spelling th-cmuir.6653943832-618702018-09-11T09:00:30Z Complications of loop electrosurgical excision procedure for cervical neoplasia: A prospective study Chumnan Kietpeerakool Jatupol Srisomboon Apichart Khobjai Aunchalee Chandacham Umpawan Tucksinsook Medicine Objectives: To evaluate the complications following loop electrosurgical excision procedure (LEEP) for diagnosis and treatment of cervical neoplasia. Material and Method: Descriptive cross sectional study in patients with abnormal cervical cytology who underwent LEEP at Chiang Mai University Hospital between November 2004 and July 2005 were prospectively evaluated for complications. Results: During the study periods, 206 patients underwent cervical loop excision for a total of 226 procedures. The mean age of the patients was 41 years (range, 26 -72 years). Sixty (29.1%) women were menopausal. The most common abnormal cervical cytology was HSIL (56.3%) followed by LSIL (12.1%). Twenty-five (11.1%) patients received re-excision for positive margin after the first procedure. Intraoperative hemorrhage occurred in 7.9% of the procedures. Early and late postoperative hemorrhage occurred in 0.4% and 2.6% of the procedures, respectively. Eight (3.5%) had postoperative infections and were cured with oral antibiotics. By logistic regression analysis, there was no significant correlation between age, menopausal status, HIV status, re-excision procedure, final histopathology, cone dimension and the complications of LEEP. Conclusion: Loop electrosurgical excision procedure is safe for evaluation and treatment of cervical neoplasia with an acceptable and manageable surgical morbidity. 2018-09-11T09:00:30Z 2018-09-11T09:00:30Z 2006-05-01 Journal 01252208 01252208 2-s2.0-33646794446 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33646794446&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/61870
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Medicine
spellingShingle Medicine
Chumnan Kietpeerakool
Jatupol Srisomboon
Apichart Khobjai
Aunchalee Chandacham
Umpawan Tucksinsook
Complications of loop electrosurgical excision procedure for cervical neoplasia: A prospective study
description Objectives: To evaluate the complications following loop electrosurgical excision procedure (LEEP) for diagnosis and treatment of cervical neoplasia. Material and Method: Descriptive cross sectional study in patients with abnormal cervical cytology who underwent LEEP at Chiang Mai University Hospital between November 2004 and July 2005 were prospectively evaluated for complications. Results: During the study periods, 206 patients underwent cervical loop excision for a total of 226 procedures. The mean age of the patients was 41 years (range, 26 -72 years). Sixty (29.1%) women were menopausal. The most common abnormal cervical cytology was HSIL (56.3%) followed by LSIL (12.1%). Twenty-five (11.1%) patients received re-excision for positive margin after the first procedure. Intraoperative hemorrhage occurred in 7.9% of the procedures. Early and late postoperative hemorrhage occurred in 0.4% and 2.6% of the procedures, respectively. Eight (3.5%) had postoperative infections and were cured with oral antibiotics. By logistic regression analysis, there was no significant correlation between age, menopausal status, HIV status, re-excision procedure, final histopathology, cone dimension and the complications of LEEP. Conclusion: Loop electrosurgical excision procedure is safe for evaluation and treatment of cervical neoplasia with an acceptable and manageable surgical morbidity.
format Journal
author Chumnan Kietpeerakool
Jatupol Srisomboon
Apichart Khobjai
Aunchalee Chandacham
Umpawan Tucksinsook
author_facet Chumnan Kietpeerakool
Jatupol Srisomboon
Apichart Khobjai
Aunchalee Chandacham
Umpawan Tucksinsook
author_sort Chumnan Kietpeerakool
title Complications of loop electrosurgical excision procedure for cervical neoplasia: A prospective study
title_short Complications of loop electrosurgical excision procedure for cervical neoplasia: A prospective study
title_full Complications of loop electrosurgical excision procedure for cervical neoplasia: A prospective study
title_fullStr Complications of loop electrosurgical excision procedure for cervical neoplasia: A prospective study
title_full_unstemmed Complications of loop electrosurgical excision procedure for cervical neoplasia: A prospective study
title_sort complications of loop electrosurgical excision procedure for cervical neoplasia: a prospective study
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33646794446&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/61870
_version_ 1681425701286182912