Comparison of two in vitro sensitivity tests for Plasmodium falciparum
The main purpose of the study was to compare the in vitro sensitivity results obtained from the two widely-used in vitro systems: (1) standard WHO micro-technique based on schizont maturation inhibition using fresh isolates (M-I), and (2) micro-technique based on incorporation of [3H]- hypoxanthine...
Saved in:
Main Authors: | , , , , , , , |
---|---|
Format: | Journal |
Published: |
2018
|
Subjects: | |
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33744504177&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/61917 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-61917 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-619172018-09-11T09:01:20Z Comparison of two in vitro sensitivity tests for Plasmodium falciparum Wanna Chaijaroenkul Pongsri Tippawangkosol Jiraporn Kuesap Kanungnit Congpuong Ronnatrai Ruenweerayut Nantana Suwandittakul Dujdaw Songthammawat Kesara Na-Bangchang Medicine The main purpose of the study was to compare the in vitro sensitivity results obtained from the two widely-used in vitro systems: (1) standard WHO micro-technique based on schizont maturation inhibition using fresh isolates (M-I), and (2) micro-technique based on incorporation of [3H]- hypoxanthine using culture-adapted isolates (M-II). The study was conducted during 1998 and 2002. A total of 473 Plasmodium falciparum isolates were collected from five highly malaria endemic areas of Thailand, ie, Mae Sot district, Tak (north-western), Kanchanaburi (western), Ranong (south-western), Ratchaburi (south-western) and Chantaburi (eastern) Provinces. The antimalarials tested were: mefloquine, quinine, chloroquine, artemisinin and dihydroartemisinin. The sensitivity results for mefloquine obtained from the two methods were significantly different from each other. The IC50values for M-II was less than M-I. The median (95%C.I.) IC50value for mefloquine using the M-II method was significantly lower [696.47 (393.11-1,233.2) nM] than for M-I [3,955.4 (1,035.61-5,108.9) nM]. The in vitro sensitivity results for quinine were significantly different from each other. The median (95% C.I.) IC50value for M-II [161 (42-351) nM] was 2.5-fold that of M-I [66 (24-450) nM]. 2018-09-11T09:01:20Z 2018-09-11T09:01:20Z 2006-01-01 Journal 01251562 2-s2.0-33744504177 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33744504177&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/61917 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
topic |
Medicine |
spellingShingle |
Medicine Wanna Chaijaroenkul Pongsri Tippawangkosol Jiraporn Kuesap Kanungnit Congpuong Ronnatrai Ruenweerayut Nantana Suwandittakul Dujdaw Songthammawat Kesara Na-Bangchang Comparison of two in vitro sensitivity tests for Plasmodium falciparum |
description |
The main purpose of the study was to compare the in vitro sensitivity results obtained from the two widely-used in vitro systems: (1) standard WHO micro-technique based on schizont maturation inhibition using fresh isolates (M-I), and (2) micro-technique based on incorporation of [3H]- hypoxanthine using culture-adapted isolates (M-II). The study was conducted during 1998 and 2002. A total of 473 Plasmodium falciparum isolates were collected from five highly malaria endemic areas of Thailand, ie, Mae Sot district, Tak (north-western), Kanchanaburi (western), Ranong (south-western), Ratchaburi (south-western) and Chantaburi (eastern) Provinces. The antimalarials tested were: mefloquine, quinine, chloroquine, artemisinin and dihydroartemisinin. The sensitivity results for mefloquine obtained from the two methods were significantly different from each other. The IC50values for M-II was less than M-I. The median (95%C.I.) IC50value for mefloquine using the M-II method was significantly lower [696.47 (393.11-1,233.2) nM] than for M-I [3,955.4 (1,035.61-5,108.9) nM]. The in vitro sensitivity results for quinine were significantly different from each other. The median (95% C.I.) IC50value for M-II [161 (42-351) nM] was 2.5-fold that of M-I [66 (24-450) nM]. |
format |
Journal |
author |
Wanna Chaijaroenkul Pongsri Tippawangkosol Jiraporn Kuesap Kanungnit Congpuong Ronnatrai Ruenweerayut Nantana Suwandittakul Dujdaw Songthammawat Kesara Na-Bangchang |
author_facet |
Wanna Chaijaroenkul Pongsri Tippawangkosol Jiraporn Kuesap Kanungnit Congpuong Ronnatrai Ruenweerayut Nantana Suwandittakul Dujdaw Songthammawat Kesara Na-Bangchang |
author_sort |
Wanna Chaijaroenkul |
title |
Comparison of two in vitro sensitivity tests for Plasmodium falciparum |
title_short |
Comparison of two in vitro sensitivity tests for Plasmodium falciparum |
title_full |
Comparison of two in vitro sensitivity tests for Plasmodium falciparum |
title_fullStr |
Comparison of two in vitro sensitivity tests for Plasmodium falciparum |
title_full_unstemmed |
Comparison of two in vitro sensitivity tests for Plasmodium falciparum |
title_sort |
comparison of two in vitro sensitivity tests for plasmodium falciparum |
publishDate |
2018 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33744504177&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/61917 |
_version_ |
1681425710008238080 |