Comparison of retinal nerve fiber layer thickness and optic disk algorithms with optical coherence tomography to detect glaucoma

• PURPOSE: To compare the performance of the retinal nerve fiber layer (RNFL) thickness and optic disk algorithms as determined by optical coherence tomography to detect glaucoma. • DESIGN: Observational cross-sectional study. • METHODS: setting: Academic tertiary-care center. study population: One...

Full description

Saved in:
Bibliographic Details
Main Authors: Anita Manassakorn, Kouros Nouri-Mahdavi, Joseph Caprioli
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=29544451185&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/61919
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-61919
record_format dspace
spelling th-cmuir.6653943832-619192018-09-11T09:01:21Z Comparison of retinal nerve fiber layer thickness and optic disk algorithms with optical coherence tomography to detect glaucoma Anita Manassakorn Kouros Nouri-Mahdavi Joseph Caprioli Medicine • PURPOSE: To compare the performance of the retinal nerve fiber layer (RNFL) thickness and optic disk algorithms as determined by optical coherence tomography to detect glaucoma. • DESIGN: Observational cross-sectional study. • METHODS: setting: Academic tertiary-care center. study population: One eye from 42 control subjects and 65 patients with open-angle glaucoma with visual acuity of ≥20/40, and no other ocular pathologic condition. observation procedures: Two optical coherence tomography algorithms were used: "fast RNFL thickness" and "fast optic disk." main outcome measures: Area under the receiver operating characteristic curves and sensitivities at fixed specificities were used. Discriminating ability of the average RNFL thickness and RNFL thickness in clock-hour sectors and quadrants was compared with the parameters that were derived from the fast optic disk algorithm. Classification and regression trees were used to determine the best combination of parameters for the detection of glaucoma. • RESULTS: The average visual field mean deviation (±SD) was 0.0 ± 1.3 and -5.3 ± 5.0 dB in the control and glaucoma groups, respectively. The RNFL thickness at the 7 o'clock sector, inferior quadrant, and the vertical C/D ratio had the highest area under the receiver operating characteristic curves (0.93 ± 0.02, 0.92 ± 0.03, and 0.90 ± 0.03, respectively). At 90% specificity, the best sensitivities (±SE) from each algorithm were 86% ± 3% for RNFL thickness at the 7 o'clock sector and 79% ± 4% for horizontal integrated rim width (estimated rim area). The combination of inferior quadrant RNFL thickness and vertical C/D ratio achieved the best classification (misclassification rate, 6.2%). • CONCLUSION: The fast optic disk algorithm performs as well as the fast RNFL thickness algorithm for discrimination of glaucoma from normal eyes. A combination of the two algorithms may provide enhanced diagnostic performance. © 2006 by Elsevier Inc. All rights reserved. 2018-09-11T09:01:21Z 2018-09-11T09:01:21Z 2006-01-01 Journal 00029394 2-s2.0-29544451185 10.1016/j.ajo.2005.08.023 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=29544451185&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/61919
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Medicine
spellingShingle Medicine
Anita Manassakorn
Kouros Nouri-Mahdavi
Joseph Caprioli
Comparison of retinal nerve fiber layer thickness and optic disk algorithms with optical coherence tomography to detect glaucoma
description • PURPOSE: To compare the performance of the retinal nerve fiber layer (RNFL) thickness and optic disk algorithms as determined by optical coherence tomography to detect glaucoma. • DESIGN: Observational cross-sectional study. • METHODS: setting: Academic tertiary-care center. study population: One eye from 42 control subjects and 65 patients with open-angle glaucoma with visual acuity of ≥20/40, and no other ocular pathologic condition. observation procedures: Two optical coherence tomography algorithms were used: "fast RNFL thickness" and "fast optic disk." main outcome measures: Area under the receiver operating characteristic curves and sensitivities at fixed specificities were used. Discriminating ability of the average RNFL thickness and RNFL thickness in clock-hour sectors and quadrants was compared with the parameters that were derived from the fast optic disk algorithm. Classification and regression trees were used to determine the best combination of parameters for the detection of glaucoma. • RESULTS: The average visual field mean deviation (±SD) was 0.0 ± 1.3 and -5.3 ± 5.0 dB in the control and glaucoma groups, respectively. The RNFL thickness at the 7 o'clock sector, inferior quadrant, and the vertical C/D ratio had the highest area under the receiver operating characteristic curves (0.93 ± 0.02, 0.92 ± 0.03, and 0.90 ± 0.03, respectively). At 90% specificity, the best sensitivities (±SE) from each algorithm were 86% ± 3% for RNFL thickness at the 7 o'clock sector and 79% ± 4% for horizontal integrated rim width (estimated rim area). The combination of inferior quadrant RNFL thickness and vertical C/D ratio achieved the best classification (misclassification rate, 6.2%). • CONCLUSION: The fast optic disk algorithm performs as well as the fast RNFL thickness algorithm for discrimination of glaucoma from normal eyes. A combination of the two algorithms may provide enhanced diagnostic performance. © 2006 by Elsevier Inc. All rights reserved.
format Journal
author Anita Manassakorn
Kouros Nouri-Mahdavi
Joseph Caprioli
author_facet Anita Manassakorn
Kouros Nouri-Mahdavi
Joseph Caprioli
author_sort Anita Manassakorn
title Comparison of retinal nerve fiber layer thickness and optic disk algorithms with optical coherence tomography to detect glaucoma
title_short Comparison of retinal nerve fiber layer thickness and optic disk algorithms with optical coherence tomography to detect glaucoma
title_full Comparison of retinal nerve fiber layer thickness and optic disk algorithms with optical coherence tomography to detect glaucoma
title_fullStr Comparison of retinal nerve fiber layer thickness and optic disk algorithms with optical coherence tomography to detect glaucoma
title_full_unstemmed Comparison of retinal nerve fiber layer thickness and optic disk algorithms with optical coherence tomography to detect glaucoma
title_sort comparison of retinal nerve fiber layer thickness and optic disk algorithms with optical coherence tomography to detect glaucoma
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=29544451185&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/61919
_version_ 1681425710371045376