Performance testing of cross flow heat exchanger operating in the atmosphere of flue gas particulate with vapor condensation

Performance testing of a cross flow heat exchanger operating under the atmosphere of flue gas particulate from combustion was carried out in this work. This heat exchanger exchanges heat between flue gas from the fuel oil combustion and cold water. The heat exchanger is composed of a spiral finned t...

Full description

Saved in:
Bibliographic Details
Main Authors: A. Nuntaphan, T. Kiatsiriroat
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33745711650&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/61970
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-61970
record_format dspace
spelling th-cmuir.6653943832-619702018-09-11T09:03:07Z Performance testing of cross flow heat exchanger operating in the atmosphere of flue gas particulate with vapor condensation A. Nuntaphan T. Kiatsiriroat Multidisciplinary Performance testing of a cross flow heat exchanger operating under the atmosphere of flue gas particulate from combustion was carried out in this work. This heat exchanger exchanges heat between flue gas from the fuel oil combustion and cold water. The heat exchanger is composed of a spiral finned tube bank having 3 rows and 8 tubes per row with a staggered arrangement. The fin spacings considered are 2.85 and 6.10 mm. The theories of thermodynamics and heat transfer are used for analyzing the performance of this system. In this experiment, the flue gas temperature of 200°-C from combustion having 0.35 kg/s mass flow rate flows along outside surface of the heat exchanger and transfers heat to the 25°-C cooling water having 0.15 kg/s mass flow rate flowing in the tube side. Each experiment uses 750 hr for testing. During the testing, part of flue gas condenses on the heat transfer surface. From the experiment, it was found that the heat transfer rate of both heat exchangers tended to decrease with time while the airside pressure drop increased. These results come from the fouling on the heat transfer surface. Moreover, it is found that the heat exchanger having 2.85 mm fin spacing has an approximately 4 times higher fouling resistance than that of the 6.10 mm fin spacing. In this work a model for calculating the fouling resistance is also developed as a the function of time. The model is developed from that of Kern and Seaton and the mean deviation of the model is 0.789. 2018-09-11T09:03:07Z 2018-09-11T09:03:07Z 2006-05-01 Journal 01253395 2-s2.0-33745711650 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33745711650&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/61970
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Multidisciplinary
spellingShingle Multidisciplinary
A. Nuntaphan
T. Kiatsiriroat
Performance testing of cross flow heat exchanger operating in the atmosphere of flue gas particulate with vapor condensation
description Performance testing of a cross flow heat exchanger operating under the atmosphere of flue gas particulate from combustion was carried out in this work. This heat exchanger exchanges heat between flue gas from the fuel oil combustion and cold water. The heat exchanger is composed of a spiral finned tube bank having 3 rows and 8 tubes per row with a staggered arrangement. The fin spacings considered are 2.85 and 6.10 mm. The theories of thermodynamics and heat transfer are used for analyzing the performance of this system. In this experiment, the flue gas temperature of 200°-C from combustion having 0.35 kg/s mass flow rate flows along outside surface of the heat exchanger and transfers heat to the 25°-C cooling water having 0.15 kg/s mass flow rate flowing in the tube side. Each experiment uses 750 hr for testing. During the testing, part of flue gas condenses on the heat transfer surface. From the experiment, it was found that the heat transfer rate of both heat exchangers tended to decrease with time while the airside pressure drop increased. These results come from the fouling on the heat transfer surface. Moreover, it is found that the heat exchanger having 2.85 mm fin spacing has an approximately 4 times higher fouling resistance than that of the 6.10 mm fin spacing. In this work a model for calculating the fouling resistance is also developed as a the function of time. The model is developed from that of Kern and Seaton and the mean deviation of the model is 0.789.
format Journal
author A. Nuntaphan
T. Kiatsiriroat
author_facet A. Nuntaphan
T. Kiatsiriroat
author_sort A. Nuntaphan
title Performance testing of cross flow heat exchanger operating in the atmosphere of flue gas particulate with vapor condensation
title_short Performance testing of cross flow heat exchanger operating in the atmosphere of flue gas particulate with vapor condensation
title_full Performance testing of cross flow heat exchanger operating in the atmosphere of flue gas particulate with vapor condensation
title_fullStr Performance testing of cross flow heat exchanger operating in the atmosphere of flue gas particulate with vapor condensation
title_full_unstemmed Performance testing of cross flow heat exchanger operating in the atmosphere of flue gas particulate with vapor condensation
title_sort performance testing of cross flow heat exchanger operating in the atmosphere of flue gas particulate with vapor condensation
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33745711650&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/61970
_version_ 1681425719844929536