A novel stopped flow injection - Amperometric procedure for the determination of chlorate
A novel stopped flow injection - amperometric (sFI-Amp) procedure for determination of chlorate has been developed. The reaction of chlorate with excess potassium iodide and hydrochloric acid, forming iodine/triiodide that is further electrochemically reduced at a glassy carbon electrode at +200 mV...
Saved in:
Main Authors: | , , |
---|---|
Format: | Journal |
Published: |
2018
|
Subjects: | |
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=27744503906&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/62136 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-62136 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-621362018-09-11T09:22:25Z A novel stopped flow injection - Amperometric procedure for the determination of chlorate Orawan Tue-Ngeun Jaroon Jakmunee Kate Grudpan Chemistry A novel stopped flow injection - amperometric (sFI-Amp) procedure for determination of chlorate has been developed. The reaction of chlorate with excess potassium iodide and hydrochloric acid, forming iodine/triiodide that is further electrochemically reduced at a glassy carbon electrode at +200 mV versus Ag/AgCl electrode is employed. In order to increase sensitivity without using of too high acid concentration, promoting of the reaction by increasing reaction time and temperature can be carried out. This can be done without increase of dispersion of the product zone by stopping the flow while the injected zone is being in a mixing coil which is immersed in a water bath of 55 ± 0.5 °C. In a closed system of FIA, a side reaction of oxygen with iodide is also minimized. Under a set of conditions, linear calibration graphs were in the ranges of 1.2 × 10-6-6.0 × 10-5mol l-1and 6.0 × 10-5-6.0 × 10-4mol l-1. A sample throughput of 25 h-1was accomplished. Relative standard deviation was 2% (n = 21, 1.2 × 10-4mol l-1chlorate). The proposed sFI-Amp procedure was successfully applied to the determination of chlorate in soil samples from longan plantation area. © 2005 Elsevier B.V. All rights reserved. 2018-09-11T09:22:25Z 2018-09-11T09:22:25Z 2005-12-15 Journal 00399140 2-s2.0-27744503906 10.1016/j.talanta.2005.09.023 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=27744503906&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/62136 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
topic |
Chemistry |
spellingShingle |
Chemistry Orawan Tue-Ngeun Jaroon Jakmunee Kate Grudpan A novel stopped flow injection - Amperometric procedure for the determination of chlorate |
description |
A novel stopped flow injection - amperometric (sFI-Amp) procedure for determination of chlorate has been developed. The reaction of chlorate with excess potassium iodide and hydrochloric acid, forming iodine/triiodide that is further electrochemically reduced at a glassy carbon electrode at +200 mV versus Ag/AgCl electrode is employed. In order to increase sensitivity without using of too high acid concentration, promoting of the reaction by increasing reaction time and temperature can be carried out. This can be done without increase of dispersion of the product zone by stopping the flow while the injected zone is being in a mixing coil which is immersed in a water bath of 55 ± 0.5 °C. In a closed system of FIA, a side reaction of oxygen with iodide is also minimized. Under a set of conditions, linear calibration graphs were in the ranges of 1.2 × 10-6-6.0 × 10-5mol l-1and 6.0 × 10-5-6.0 × 10-4mol l-1. A sample throughput of 25 h-1was accomplished. Relative standard deviation was 2% (n = 21, 1.2 × 10-4mol l-1chlorate). The proposed sFI-Amp procedure was successfully applied to the determination of chlorate in soil samples from longan plantation area. © 2005 Elsevier B.V. All rights reserved. |
format |
Journal |
author |
Orawan Tue-Ngeun Jaroon Jakmunee Kate Grudpan |
author_facet |
Orawan Tue-Ngeun Jaroon Jakmunee Kate Grudpan |
author_sort |
Orawan Tue-Ngeun |
title |
A novel stopped flow injection - Amperometric procedure for the determination of chlorate |
title_short |
A novel stopped flow injection - Amperometric procedure for the determination of chlorate |
title_full |
A novel stopped flow injection - Amperometric procedure for the determination of chlorate |
title_fullStr |
A novel stopped flow injection - Amperometric procedure for the determination of chlorate |
title_full_unstemmed |
A novel stopped flow injection - Amperometric procedure for the determination of chlorate |
title_sort |
novel stopped flow injection - amperometric procedure for the determination of chlorate |
publishDate |
2018 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=27744503906&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/62136 |
_version_ |
1681425750750658560 |