Evaluation of on-line preconcentration and flow-injection amperometry for phosphate determination in fresh and marine waters

Dissolved reactive phosphorus (DRP) was determined as orthophosphate (PO4-P) in fresh and saline water samples by flow-injection (FI) amperometry, without and with in-valve column preconcentration. Detection is based on reduction of the product formed from the reaction of DRP with acidic molybdate a...

Full description

Saved in:
Bibliographic Details
Main Authors: Y. Udnan, I. D. McKelvie, M. R. Grace, J. Jakmunee, K. Grudpan
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=17744362273&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/62149
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-62149
record_format dspace
spelling th-cmuir.6653943832-621492018-09-11T09:22:42Z Evaluation of on-line preconcentration and flow-injection amperometry for phosphate determination in fresh and marine waters Y. Udnan I. D. McKelvie M. R. Grace J. Jakmunee K. Grudpan Chemistry Dissolved reactive phosphorus (DRP) was determined as orthophosphate (PO4-P) in fresh and saline water samples by flow-injection (FI) amperometry, without and with in-valve column preconcentration. Detection is based on reduction of the product formed from the reaction of DRP with acidic molybdate at a glassy carbon working electrode (GCE) at 220 mV versus the Ag/AgCl reference electrode. A 0.1 M potassium chloride solution was used as both supporting electrolyte and eluent in the preconcentration system. For the FI configuration without preconcentration, a detection limit of 3.4 μg P l-1and sample throughput of 70 samples h-1were achieved. The relative standard deviations for 50 and 500 μg P l-1orthophosphate standards were 5.2 and 5.9%, respectively. By incorporating an ion exchange preconcentration column, a detection limit of 0.18 μg P l-1was obtained for a 2-min preconcentration time (R.S.D.s for 0.1 and 1 μg P l-1standards were 22 and 1.0%, respectively). Potential interference from silicate, sulfide, organic phosphates and sodium chloride were investigated. Both the systems were applied to the analysis of certified reference materials and water samples. © 2005 Elsevier B.V. All rights reserved. 2018-09-11T09:22:42Z 2018-09-11T09:22:42Z 2005-04-15 Journal 00399140 2-s2.0-17744362273 10.1016/j.talanta.2004.12.064 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=17744362273&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/62149
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Chemistry
spellingShingle Chemistry
Y. Udnan
I. D. McKelvie
M. R. Grace
J. Jakmunee
K. Grudpan
Evaluation of on-line preconcentration and flow-injection amperometry for phosphate determination in fresh and marine waters
description Dissolved reactive phosphorus (DRP) was determined as orthophosphate (PO4-P) in fresh and saline water samples by flow-injection (FI) amperometry, without and with in-valve column preconcentration. Detection is based on reduction of the product formed from the reaction of DRP with acidic molybdate at a glassy carbon working electrode (GCE) at 220 mV versus the Ag/AgCl reference electrode. A 0.1 M potassium chloride solution was used as both supporting electrolyte and eluent in the preconcentration system. For the FI configuration without preconcentration, a detection limit of 3.4 μg P l-1and sample throughput of 70 samples h-1were achieved. The relative standard deviations for 50 and 500 μg P l-1orthophosphate standards were 5.2 and 5.9%, respectively. By incorporating an ion exchange preconcentration column, a detection limit of 0.18 μg P l-1was obtained for a 2-min preconcentration time (R.S.D.s for 0.1 and 1 μg P l-1standards were 22 and 1.0%, respectively). Potential interference from silicate, sulfide, organic phosphates and sodium chloride were investigated. Both the systems were applied to the analysis of certified reference materials and water samples. © 2005 Elsevier B.V. All rights reserved.
format Journal
author Y. Udnan
I. D. McKelvie
M. R. Grace
J. Jakmunee
K. Grudpan
author_facet Y. Udnan
I. D. McKelvie
M. R. Grace
J. Jakmunee
K. Grudpan
author_sort Y. Udnan
title Evaluation of on-line preconcentration and flow-injection amperometry for phosphate determination in fresh and marine waters
title_short Evaluation of on-line preconcentration and flow-injection amperometry for phosphate determination in fresh and marine waters
title_full Evaluation of on-line preconcentration and flow-injection amperometry for phosphate determination in fresh and marine waters
title_fullStr Evaluation of on-line preconcentration and flow-injection amperometry for phosphate determination in fresh and marine waters
title_full_unstemmed Evaluation of on-line preconcentration and flow-injection amperometry for phosphate determination in fresh and marine waters
title_sort evaluation of on-line preconcentration and flow-injection amperometry for phosphate determination in fresh and marine waters
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=17744362273&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/62149
_version_ 1681425753142460416