Evaluation of on-line preconcentration and flow-injection amperometry for phosphate determination in fresh and marine waters
Dissolved reactive phosphorus (DRP) was determined as orthophosphate (PO4-P) in fresh and saline water samples by flow-injection (FI) amperometry, without and with in-valve column preconcentration. Detection is based on reduction of the product formed from the reaction of DRP with acidic molybdate a...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Journal |
Published: |
2018
|
Subjects: | |
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=17744362273&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/62149 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-62149 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-621492018-09-11T09:22:42Z Evaluation of on-line preconcentration and flow-injection amperometry for phosphate determination in fresh and marine waters Y. Udnan I. D. McKelvie M. R. Grace J. Jakmunee K. Grudpan Chemistry Dissolved reactive phosphorus (DRP) was determined as orthophosphate (PO4-P) in fresh and saline water samples by flow-injection (FI) amperometry, without and with in-valve column preconcentration. Detection is based on reduction of the product formed from the reaction of DRP with acidic molybdate at a glassy carbon working electrode (GCE) at 220 mV versus the Ag/AgCl reference electrode. A 0.1 M potassium chloride solution was used as both supporting electrolyte and eluent in the preconcentration system. For the FI configuration without preconcentration, a detection limit of 3.4 μg P l-1and sample throughput of 70 samples h-1were achieved. The relative standard deviations for 50 and 500 μg P l-1orthophosphate standards were 5.2 and 5.9%, respectively. By incorporating an ion exchange preconcentration column, a detection limit of 0.18 μg P l-1was obtained for a 2-min preconcentration time (R.S.D.s for 0.1 and 1 μg P l-1standards were 22 and 1.0%, respectively). Potential interference from silicate, sulfide, organic phosphates and sodium chloride were investigated. Both the systems were applied to the analysis of certified reference materials and water samples. © 2005 Elsevier B.V. All rights reserved. 2018-09-11T09:22:42Z 2018-09-11T09:22:42Z 2005-04-15 Journal 00399140 2-s2.0-17744362273 10.1016/j.talanta.2004.12.064 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=17744362273&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/62149 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
topic |
Chemistry |
spellingShingle |
Chemistry Y. Udnan I. D. McKelvie M. R. Grace J. Jakmunee K. Grudpan Evaluation of on-line preconcentration and flow-injection amperometry for phosphate determination in fresh and marine waters |
description |
Dissolved reactive phosphorus (DRP) was determined as orthophosphate (PO4-P) in fresh and saline water samples by flow-injection (FI) amperometry, without and with in-valve column preconcentration. Detection is based on reduction of the product formed from the reaction of DRP with acidic molybdate at a glassy carbon working electrode (GCE) at 220 mV versus the Ag/AgCl reference electrode. A 0.1 M potassium chloride solution was used as both supporting electrolyte and eluent in the preconcentration system. For the FI configuration without preconcentration, a detection limit of 3.4 μg P l-1and sample throughput of 70 samples h-1were achieved. The relative standard deviations for 50 and 500 μg P l-1orthophosphate standards were 5.2 and 5.9%, respectively. By incorporating an ion exchange preconcentration column, a detection limit of 0.18 μg P l-1was obtained for a 2-min preconcentration time (R.S.D.s for 0.1 and 1 μg P l-1standards were 22 and 1.0%, respectively). Potential interference from silicate, sulfide, organic phosphates and sodium chloride were investigated. Both the systems were applied to the analysis of certified reference materials and water samples. © 2005 Elsevier B.V. All rights reserved. |
format |
Journal |
author |
Y. Udnan I. D. McKelvie M. R. Grace J. Jakmunee K. Grudpan |
author_facet |
Y. Udnan I. D. McKelvie M. R. Grace J. Jakmunee K. Grudpan |
author_sort |
Y. Udnan |
title |
Evaluation of on-line preconcentration and flow-injection amperometry for phosphate determination in fresh and marine waters |
title_short |
Evaluation of on-line preconcentration and flow-injection amperometry for phosphate determination in fresh and marine waters |
title_full |
Evaluation of on-line preconcentration and flow-injection amperometry for phosphate determination in fresh and marine waters |
title_fullStr |
Evaluation of on-line preconcentration and flow-injection amperometry for phosphate determination in fresh and marine waters |
title_full_unstemmed |
Evaluation of on-line preconcentration and flow-injection amperometry for phosphate determination in fresh and marine waters |
title_sort |
evaluation of on-line preconcentration and flow-injection amperometry for phosphate determination in fresh and marine waters |
publishDate |
2018 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=17744362273&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/62149 |
_version_ |
1681425753142460416 |