Two-hole side-plate DHS in the treatment of intertrochanteric fracture: Results and complications
We reviewed 83 intertrochanteric fractures fixed with a 135 degree dynamic hip screw (DHS) and two-hole side-plate. The mean age was 72 years. There were 13 A1.1, 24 A1.2, 16 A2.1, 29 A2.2 and 1 A2.3 fractures. Established osteoporosis was seen in 55 patients. The mean time to union was 14.5 weeks....
Saved in:
Main Authors: | , , |
---|---|
Format: | Journal |
Published: |
2018
|
Subjects: | |
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=26444453569&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/62323 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
Summary: | We reviewed 83 intertrochanteric fractures fixed with a 135 degree dynamic hip screw (DHS) and two-hole side-plate. The mean age was 72 years. There were 13 A1.1, 24 A1.2, 16 A2.1, 29 A2.2 and 1 A2.3 fractures. Established osteoporosis was seen in 55 patients. The mean time to union was 14.5 weeks. Sixty-eight percent had minimal collapse, 24% moderate and 8% severe. Over 80% of moderate and severe collapses were associated with osteoporosis and an unstable fracture pattern. There were four failures: two from lag screw cut-out and two from pull-out of the side-plate. © 2005 Elsevier Ltd. All rights reserved. |
---|