Variability of nuchal translucency measurement: A multicenter study in Thailand

Objectives: To evaluate intra- and inter-observer variations of nuchal translucency (NT) measurements and study the duration of measurements. Subjects: One hundred and forty-seven singleton pregnant women with 10-14 weeks of gestation who had attended antenatal clinic during January 1st, 2000-August...

Full description

Saved in:
Bibliographic Details
Main Authors: Thitima Suntharasaj, Thawalwong Ratanasiri, Pharuhas Chanprapaph, Chitkasaem Kengpol, Ounjai Kor-anantakul, Roengsak Leetanaporn, Visit Prasartwanakit, Pilaiwan Kleebkaow, Theera Tongsong, Supatra Sirichotiyakul
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=27644466851&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/62327
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-62327
record_format dspace
spelling th-cmuir.6653943832-623272018-09-11T09:25:43Z Variability of nuchal translucency measurement: A multicenter study in Thailand Thitima Suntharasaj Thawalwong Ratanasiri Pharuhas Chanprapaph Chitkasaem Kengpol Ounjai Kor-anantakul Roengsak Leetanaporn Visit Prasartwanakit Pilaiwan Kleebkaow Theera Tongsong Supatra Sirichotiyakul Medicine Objectives: To evaluate intra- and inter-observer variations of nuchal translucency (NT) measurements and study the duration of measurements. Subjects: One hundred and forty-seven singleton pregnant women with 10-14 weeks of gestation who had attended antenatal clinic during January 1st, 2000-August 31st, 2001 were included. Methods: Crown-rump length and NT were measured three times for each woman. Then, another examiner who was unaware of the previous results did the other three measurements. The duration of measurements was recorded. Intra-observer and inter-observer variations were analyzed by repeated ANOVA and paired t test, respectively. The correlation of NT measurements within each observer and between paired observers was evaluated by intraclass correlation coefficients (ICC). Kappa statistic was calculated for agreement. Results: Intra-observer variation of all 10 examiners at three institutes was varied from 0.20 ± 0.27 to 0.33 ± 0.41 mm. Inter-observer variation at Chiang Mai University was 0.40 ± 0.37 mm which was the highest value compared with those at Prince of Songkla and Khon Kaen University (p < 0.05). The mean duration of measurements was in range of 8-12 min. The intra-observer repeatability of the first two measurements showed ICCs varying from 0.61 to 0.94. The inter-observer repeatability of paired examiners showed a variation in ICC from 0.28-0.90. The kappa value expressing the intra- and inter-observer repeatability as being >95th or <95th percentile was 0.73 and 0.72, respectively. Conclusions: NT measurement was reproducible for small variation and good agreement. The duration of measurements was acceptable. Copyright © 2005 S. Karger AG. 2018-09-11T09:25:43Z 2018-09-11T09:25:43Z 2005-11-01 Journal 03787346 2-s2.0-27644466851 10.1159/000087206 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=27644466851&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/62327
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Medicine
spellingShingle Medicine
Thitima Suntharasaj
Thawalwong Ratanasiri
Pharuhas Chanprapaph
Chitkasaem Kengpol
Ounjai Kor-anantakul
Roengsak Leetanaporn
Visit Prasartwanakit
Pilaiwan Kleebkaow
Theera Tongsong
Supatra Sirichotiyakul
Variability of nuchal translucency measurement: A multicenter study in Thailand
description Objectives: To evaluate intra- and inter-observer variations of nuchal translucency (NT) measurements and study the duration of measurements. Subjects: One hundred and forty-seven singleton pregnant women with 10-14 weeks of gestation who had attended antenatal clinic during January 1st, 2000-August 31st, 2001 were included. Methods: Crown-rump length and NT were measured three times for each woman. Then, another examiner who was unaware of the previous results did the other three measurements. The duration of measurements was recorded. Intra-observer and inter-observer variations were analyzed by repeated ANOVA and paired t test, respectively. The correlation of NT measurements within each observer and between paired observers was evaluated by intraclass correlation coefficients (ICC). Kappa statistic was calculated for agreement. Results: Intra-observer variation of all 10 examiners at three institutes was varied from 0.20 ± 0.27 to 0.33 ± 0.41 mm. Inter-observer variation at Chiang Mai University was 0.40 ± 0.37 mm which was the highest value compared with those at Prince of Songkla and Khon Kaen University (p < 0.05). The mean duration of measurements was in range of 8-12 min. The intra-observer repeatability of the first two measurements showed ICCs varying from 0.61 to 0.94. The inter-observer repeatability of paired examiners showed a variation in ICC from 0.28-0.90. The kappa value expressing the intra- and inter-observer repeatability as being >95th or <95th percentile was 0.73 and 0.72, respectively. Conclusions: NT measurement was reproducible for small variation and good agreement. The duration of measurements was acceptable. Copyright © 2005 S. Karger AG.
format Journal
author Thitima Suntharasaj
Thawalwong Ratanasiri
Pharuhas Chanprapaph
Chitkasaem Kengpol
Ounjai Kor-anantakul
Roengsak Leetanaporn
Visit Prasartwanakit
Pilaiwan Kleebkaow
Theera Tongsong
Supatra Sirichotiyakul
author_facet Thitima Suntharasaj
Thawalwong Ratanasiri
Pharuhas Chanprapaph
Chitkasaem Kengpol
Ounjai Kor-anantakul
Roengsak Leetanaporn
Visit Prasartwanakit
Pilaiwan Kleebkaow
Theera Tongsong
Supatra Sirichotiyakul
author_sort Thitima Suntharasaj
title Variability of nuchal translucency measurement: A multicenter study in Thailand
title_short Variability of nuchal translucency measurement: A multicenter study in Thailand
title_full Variability of nuchal translucency measurement: A multicenter study in Thailand
title_fullStr Variability of nuchal translucency measurement: A multicenter study in Thailand
title_full_unstemmed Variability of nuchal translucency measurement: A multicenter study in Thailand
title_sort variability of nuchal translucency measurement: a multicenter study in thailand
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=27644466851&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/62327
_version_ 1681425786213498880