Mobile-phone-based colourimetric analysis for determining nitrite content in water

© 2018 CSIRO. A cost-effective and portable colourimetric analyser installed on a mobile phone was used to measure nitrite in water samples in Chiang Mai City, Thailand. The colourimetric detection was based on the Griess reaction, in which nitrite ion reacts with sulfanilic acid under acidic condit...

Full description

Saved in:
Bibliographic Details
Main Authors: Chanida Puangpila, Jaroon Jakmunee, Somkid Pencharee, Wipada Pensrisirikul
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85055584332&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/62641
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-62641
record_format dspace
spelling th-cmuir.6653943832-626412018-11-29T07:44:27Z Mobile-phone-based colourimetric analysis for determining nitrite content in water Chanida Puangpila Jaroon Jakmunee Somkid Pencharee Wipada Pensrisirikul Chemistry Earth and Planetary Sciences Environmental Science © 2018 CSIRO. A cost-effective and portable colourimetric analyser installed on a mobile phone was used to measure nitrite in water samples in Chiang Mai City, Thailand. The colourimetric detection was based on the Griess reaction, in which nitrite ion reacts with sulfanilic acid under acidic conditions to produce a diazonium salt that further reacts with N-(1-naphthyl)-ethylenediamine dihydrochloride to form a red-violet azo dye. Under controlled conditions using a light-tight box with LED flash lights, images of the red-violet solution were captured using a built-in camera and further analysed by a program, Panalysis, on the mobile phone. The calibration graph was created by measuring the red colour intensity of a series of standard nitrite solutions from 0.09-1.8 mg N L-1. The calibration equation was then automatically stored for nitrite analysis. The results demonstrated good performance of the mobile phone analyser as an analytical instrument. The accuracy (RE <4%) and precision (RSD ≤ 1%, intra- and inter-day) were also obtained with a detection limit of 0.03 mg N L-1 and a sample throughput of 40 samples per hour. Our results establish this simple, inexpensive and portable device as a reliable in-field monitor of nitrite in environmental waters. 2018-11-29T07:37:45Z 2018-11-29T07:37:45Z 2018-01-01 Journal 14482517 2-s2.0-85055584332 10.1071/EN18072 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85055584332&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/62641
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Chemistry
Earth and Planetary Sciences
Environmental Science
spellingShingle Chemistry
Earth and Planetary Sciences
Environmental Science
Chanida Puangpila
Jaroon Jakmunee
Somkid Pencharee
Wipada Pensrisirikul
Mobile-phone-based colourimetric analysis for determining nitrite content in water
description © 2018 CSIRO. A cost-effective and portable colourimetric analyser installed on a mobile phone was used to measure nitrite in water samples in Chiang Mai City, Thailand. The colourimetric detection was based on the Griess reaction, in which nitrite ion reacts with sulfanilic acid under acidic conditions to produce a diazonium salt that further reacts with N-(1-naphthyl)-ethylenediamine dihydrochloride to form a red-violet azo dye. Under controlled conditions using a light-tight box with LED flash lights, images of the red-violet solution were captured using a built-in camera and further analysed by a program, Panalysis, on the mobile phone. The calibration graph was created by measuring the red colour intensity of a series of standard nitrite solutions from 0.09-1.8 mg N L-1. The calibration equation was then automatically stored for nitrite analysis. The results demonstrated good performance of the mobile phone analyser as an analytical instrument. The accuracy (RE <4%) and precision (RSD ≤ 1%, intra- and inter-day) were also obtained with a detection limit of 0.03 mg N L-1 and a sample throughput of 40 samples per hour. Our results establish this simple, inexpensive and portable device as a reliable in-field monitor of nitrite in environmental waters.
format Journal
author Chanida Puangpila
Jaroon Jakmunee
Somkid Pencharee
Wipada Pensrisirikul
author_facet Chanida Puangpila
Jaroon Jakmunee
Somkid Pencharee
Wipada Pensrisirikul
author_sort Chanida Puangpila
title Mobile-phone-based colourimetric analysis for determining nitrite content in water
title_short Mobile-phone-based colourimetric analysis for determining nitrite content in water
title_full Mobile-phone-based colourimetric analysis for determining nitrite content in water
title_fullStr Mobile-phone-based colourimetric analysis for determining nitrite content in water
title_full_unstemmed Mobile-phone-based colourimetric analysis for determining nitrite content in water
title_sort mobile-phone-based colourimetric analysis for determining nitrite content in water
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85055584332&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/62641
_version_ 1681425845030223872