Image Quality and ADC Assessment in Turbo Spin-Echo and Echo-Planar Diffusion-Weighted MR Imaging of Tumors of the Head and Neck

© 2018 Rationale and Objectives: We aimed to compare the distortion ratio (DR), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) between turbo spin-echo (TSE)-diffusion-weighted imaging (DWI) and echo-planar imaging (EPI)-DWI of the orofacial region and prove the usefulness of TSE-DWI...

Full description

Saved in:
Bibliographic Details
Main Authors: Wannakamon Panyarak, Toru Chikui, Yasuo Yamashita, Takeshi Kamitani, Kazunori Yoshiura
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85057578796&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/62983
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-62983
record_format dspace
spelling th-cmuir.6653943832-629832018-12-14T04:07:54Z Image Quality and ADC Assessment in Turbo Spin-Echo and Echo-Planar Diffusion-Weighted MR Imaging of Tumors of the Head and Neck Wannakamon Panyarak Toru Chikui Yasuo Yamashita Takeshi Kamitani Kazunori Yoshiura Medicine © 2018 Rationale and Objectives: We aimed to compare the distortion ratio (DR), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) between turbo spin-echo (TSE)-diffusion-weighted imaging (DWI) and echo-planar imaging (EPI)-DWI of the orofacial region and prove the usefulness of TSE-DWI for the differential diagnosis of orofacial lesions. Materials and methods: The DR, SNR, and CNR of both sequences were compared in 42 cases. Then, the apparent diffusion coefficient (ADC) of various orofacial lesions obtained by TSE-DWI was investigated in 143 lesions. Results: In the first study, 38 of 42 cases were analyzed. TSE-DWI showed a significantly lower DR (p < 0.05) and higher SNR and CNR than EPI-DWI (p < 0.05), indicating the superiority of TSE-DWI. In the second study, 114 cases (79.3%) were successfully analyzed. When lesions were divided into cysts, benign tumors, squamous cell carcinoma, malignant lymphoma, and other malignant tumors (OT), significant differences were observed in all pairs of lesions (p < 0.05) except squamous cell carcinoma and OT (p = 0.877). The area under the curve for distinguishing benign from malignant tumors was 0.80 with a cutoff ADC of 1.29 × 10-3 mm²/s. Conclusion: TSE-DWI produced better quality images than EPI-DWI. TSE-DWI yields the high possibility of obtaining ADC in the orofacial region, and this value was considered useful for the differential diagnosis of orofacial lesions. 2018-12-14T04:07:54Z 2018-12-14T04:07:54Z 2018-01-01 Journal 18784046 10766332 2-s2.0-85057578796 10.1016/j.acra.2018.11.016 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85057578796&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/62983
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Medicine
spellingShingle Medicine
Wannakamon Panyarak
Toru Chikui
Yasuo Yamashita
Takeshi Kamitani
Kazunori Yoshiura
Image Quality and ADC Assessment in Turbo Spin-Echo and Echo-Planar Diffusion-Weighted MR Imaging of Tumors of the Head and Neck
description © 2018 Rationale and Objectives: We aimed to compare the distortion ratio (DR), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) between turbo spin-echo (TSE)-diffusion-weighted imaging (DWI) and echo-planar imaging (EPI)-DWI of the orofacial region and prove the usefulness of TSE-DWI for the differential diagnosis of orofacial lesions. Materials and methods: The DR, SNR, and CNR of both sequences were compared in 42 cases. Then, the apparent diffusion coefficient (ADC) of various orofacial lesions obtained by TSE-DWI was investigated in 143 lesions. Results: In the first study, 38 of 42 cases were analyzed. TSE-DWI showed a significantly lower DR (p < 0.05) and higher SNR and CNR than EPI-DWI (p < 0.05), indicating the superiority of TSE-DWI. In the second study, 114 cases (79.3%) were successfully analyzed. When lesions were divided into cysts, benign tumors, squamous cell carcinoma, malignant lymphoma, and other malignant tumors (OT), significant differences were observed in all pairs of lesions (p < 0.05) except squamous cell carcinoma and OT (p = 0.877). The area under the curve for distinguishing benign from malignant tumors was 0.80 with a cutoff ADC of 1.29 × 10-3 mm²/s. Conclusion: TSE-DWI produced better quality images than EPI-DWI. TSE-DWI yields the high possibility of obtaining ADC in the orofacial region, and this value was considered useful for the differential diagnosis of orofacial lesions.
format Journal
author Wannakamon Panyarak
Toru Chikui
Yasuo Yamashita
Takeshi Kamitani
Kazunori Yoshiura
author_facet Wannakamon Panyarak
Toru Chikui
Yasuo Yamashita
Takeshi Kamitani
Kazunori Yoshiura
author_sort Wannakamon Panyarak
title Image Quality and ADC Assessment in Turbo Spin-Echo and Echo-Planar Diffusion-Weighted MR Imaging of Tumors of the Head and Neck
title_short Image Quality and ADC Assessment in Turbo Spin-Echo and Echo-Planar Diffusion-Weighted MR Imaging of Tumors of the Head and Neck
title_full Image Quality and ADC Assessment in Turbo Spin-Echo and Echo-Planar Diffusion-Weighted MR Imaging of Tumors of the Head and Neck
title_fullStr Image Quality and ADC Assessment in Turbo Spin-Echo and Echo-Planar Diffusion-Weighted MR Imaging of Tumors of the Head and Neck
title_full_unstemmed Image Quality and ADC Assessment in Turbo Spin-Echo and Echo-Planar Diffusion-Weighted MR Imaging of Tumors of the Head and Neck
title_sort image quality and adc assessment in turbo spin-echo and echo-planar diffusion-weighted mr imaging of tumors of the head and neck
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85057578796&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/62983
_version_ 1681425907723534336