Determination of Cadmium and Lead in Concrete Roofing Tiles by Differential Pulse Anodic Stripping Voltammetric Method

Differential pulse anodic stripping voltammetric method has been developed for determination of cadmium and lead released from concrete roofing tiles. The sample was extracted with water for 24 h according to the TIS 535-2540 standard method. An aliquot of 5 mL of the extracted solution and 5 mL of...

Full description

Saved in:
Bibliographic Details
Main Authors: Jaroon Junsomboon, Jaroon Jakmunee
Format: บทความวารสาร
Language:English
Published: Science Faculty of Chiang Mai University 2019
Online Access:http://it.science.cmu.ac.th/ejournal/dl.php?journal_id=7370
http://cmuir.cmu.ac.th/jspui/handle/6653943832/63804
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
Language: English
id th-cmuir.6653943832-63804
record_format dspace
spelling th-cmuir.6653943832-638042019-05-07T09:57:19Z Determination of Cadmium and Lead in Concrete Roofing Tiles by Differential Pulse Anodic Stripping Voltammetric Method Jaroon Junsomboon Jaroon Jakmunee Differential pulse anodic stripping voltammetric method has been developed for determination of cadmium and lead released from concrete roofing tiles. The sample was extracted with water for 24 h according to the TIS 535-2540 standard method. An aliquot of 5 mL of the extracted solution and 5 mL of 4% v/v acetic acid solution were put in a voltammetric cell. Then, the solution was stirred at 2000 rpm and purged with nitrogen gas for 3 min before the deposition of the metals was carried out by applying a constant potential of -0.90 V versus Ag/AgCl to a hanging mercury drop electrode (HMDE) for 45 s. After that a differential pulse scanning waveform from -0.90 to -0.10 V was applied and a voltammogram was recorded. Peak current of cadmium and lead were measured at peak potentials of -0.555 and -0.364 V vs Ag/AgCl, respectively. Standard addition procedure was used for quantification. Relative standard deviation for 11 replicate determinations of 8 mgL-1 of both metals were in the range of 1.59 - 1.74%. Percentage recoveries obtained by spiking 8 mgL-1 of cadmium and lead to the sample solution were found to be 107% and with detection limit of 0.15 mgL-1 for both metals. It was found that contents of cadmium and lead released from the concrete roofing tile samples were in the range of < 0.15 - 0.49 mgL-1 and < 0.15 - 11.95 mgL-1, respectively, which are lower than the regulated values of the Thailand industrial standard (TIS 535-2540). The proposed method is simpler, more convenient and more sensitive than the standard method based on an atomic absorption spectrophototometry. 2019-05-07T09:57:19Z 2019-05-07T09:57:19Z 2016 บทความวารสาร 0125-2526 http://it.science.cmu.ac.th/ejournal/dl.php?journal_id=7370 http://cmuir.cmu.ac.th/jspui/handle/6653943832/63804 Eng Science Faculty of Chiang Mai University
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
language English
description Differential pulse anodic stripping voltammetric method has been developed for determination of cadmium and lead released from concrete roofing tiles. The sample was extracted with water for 24 h according to the TIS 535-2540 standard method. An aliquot of 5 mL of the extracted solution and 5 mL of 4% v/v acetic acid solution were put in a voltammetric cell. Then, the solution was stirred at 2000 rpm and purged with nitrogen gas for 3 min before the deposition of the metals was carried out by applying a constant potential of -0.90 V versus Ag/AgCl to a hanging mercury drop electrode (HMDE) for 45 s. After that a differential pulse scanning waveform from -0.90 to -0.10 V was applied and a voltammogram was recorded. Peak current of cadmium and lead were measured at peak potentials of -0.555 and -0.364 V vs Ag/AgCl, respectively. Standard addition procedure was used for quantification. Relative standard deviation for 11 replicate determinations of 8 mgL-1 of both metals were in the range of 1.59 - 1.74%. Percentage recoveries obtained by spiking 8 mgL-1 of cadmium and lead to the sample solution were found to be 107% and with detection limit of 0.15 mgL-1 for both metals. It was found that contents of cadmium and lead released from the concrete roofing tile samples were in the range of < 0.15 - 0.49 mgL-1 and < 0.15 - 11.95 mgL-1, respectively, which are lower than the regulated values of the Thailand industrial standard (TIS 535-2540). The proposed method is simpler, more convenient and more sensitive than the standard method based on an atomic absorption spectrophototometry.
format บทความวารสาร
author Jaroon Junsomboon
Jaroon Jakmunee
spellingShingle Jaroon Junsomboon
Jaroon Jakmunee
Determination of Cadmium and Lead in Concrete Roofing Tiles by Differential Pulse Anodic Stripping Voltammetric Method
author_facet Jaroon Junsomboon
Jaroon Jakmunee
author_sort Jaroon Junsomboon
title Determination of Cadmium and Lead in Concrete Roofing Tiles by Differential Pulse Anodic Stripping Voltammetric Method
title_short Determination of Cadmium and Lead in Concrete Roofing Tiles by Differential Pulse Anodic Stripping Voltammetric Method
title_full Determination of Cadmium and Lead in Concrete Roofing Tiles by Differential Pulse Anodic Stripping Voltammetric Method
title_fullStr Determination of Cadmium and Lead in Concrete Roofing Tiles by Differential Pulse Anodic Stripping Voltammetric Method
title_full_unstemmed Determination of Cadmium and Lead in Concrete Roofing Tiles by Differential Pulse Anodic Stripping Voltammetric Method
title_sort determination of cadmium and lead in concrete roofing tiles by differential pulse anodic stripping voltammetric method
publisher Science Faculty of Chiang Mai University
publishDate 2019
url http://it.science.cmu.ac.th/ejournal/dl.php?journal_id=7370
http://cmuir.cmu.ac.th/jspui/handle/6653943832/63804
_version_ 1681425963449057280