Comparative Study of a GEM-based Fast Neutron Detector Using 4He/CO2 and 4He/CO2/C4H10 Gas Mixtures

1H- or 4He-contained gas mixtures are usually used to detect fast neutrons, which relies on elastic scattering between fast neutrons and light gas molecules. In this research, gas mixtures of 4He/CO2 (80:20 and 70:30) and 4He/CO2/C4H10 (70:23:7) were flowed through a 10 cm×10 cm triple-Gas Electron...

Full description

Saved in:
Bibliographic Details
Main Authors: Kiadtisak Saenboonruang, Anawat Rittirong, Khem Chirapatpimol, Thiraphat Vilaithong
Format: บทความวารสาร
Language:English
Published: Science Faculty of Chiang Mai University 2019
Online Access:http://it.science.cmu.ac.th/ejournal/dl.php?journal_id=8494
http://cmuir.cmu.ac.th/jspui/handle/6653943832/63993
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
Language: English
id th-cmuir.6653943832-63993
record_format dspace
spelling th-cmuir.6653943832-639932019-05-07T09:59:42Z Comparative Study of a GEM-based Fast Neutron Detector Using 4He/CO2 and 4He/CO2/C4H10 Gas Mixtures Kiadtisak Saenboonruang Anawat Rittirong Khem Chirapatpimol Thiraphat Vilaithong 1H- or 4He-contained gas mixtures are usually used to detect fast neutrons, which relies on elastic scattering between fast neutrons and light gas molecules. In this research, gas mixtures of 4He/CO2 (80:20 and 70:30) and 4He/CO2/C4H10 (70:23:7) were flowed through a 10 cm×10 cm triple-Gas Electron Multiplier (GEM) detector at a constant flow rate of 3.0 L/hr in order to detect fast neutrons. Comparisons of relative efficiencies, relative gains, and detection uniformity for all gas types were investigated by measuring signal counts and signal amplitudes. Results showed that a gas mixture of 4He/CO2 (80:20) had the highest relative efficiency and relative gains amongst all gas mixture types. In terms of detection uniformity, detection efficiency at the center of the active area was approximately 20% higher than areas close to the detector edges. Details of basic knowledge of GEM, experimental procedures, results and discussion are included in this article. 2019-05-07T09:59:42Z 2019-05-07T09:59:42Z 2017 บทความวารสาร 0125-2526 http://it.science.cmu.ac.th/ejournal/dl.php?journal_id=8494 http://cmuir.cmu.ac.th/jspui/handle/6653943832/63993 Eng Science Faculty of Chiang Mai University
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
language English
description 1H- or 4He-contained gas mixtures are usually used to detect fast neutrons, which relies on elastic scattering between fast neutrons and light gas molecules. In this research, gas mixtures of 4He/CO2 (80:20 and 70:30) and 4He/CO2/C4H10 (70:23:7) were flowed through a 10 cm×10 cm triple-Gas Electron Multiplier (GEM) detector at a constant flow rate of 3.0 L/hr in order to detect fast neutrons. Comparisons of relative efficiencies, relative gains, and detection uniformity for all gas types were investigated by measuring signal counts and signal amplitudes. Results showed that a gas mixture of 4He/CO2 (80:20) had the highest relative efficiency and relative gains amongst all gas mixture types. In terms of detection uniformity, detection efficiency at the center of the active area was approximately 20% higher than areas close to the detector edges. Details of basic knowledge of GEM, experimental procedures, results and discussion are included in this article.
format บทความวารสาร
author Kiadtisak Saenboonruang
Anawat Rittirong
Khem Chirapatpimol
Thiraphat Vilaithong
spellingShingle Kiadtisak Saenboonruang
Anawat Rittirong
Khem Chirapatpimol
Thiraphat Vilaithong
Comparative Study of a GEM-based Fast Neutron Detector Using 4He/CO2 and 4He/CO2/C4H10 Gas Mixtures
author_facet Kiadtisak Saenboonruang
Anawat Rittirong
Khem Chirapatpimol
Thiraphat Vilaithong
author_sort Kiadtisak Saenboonruang
title Comparative Study of a GEM-based Fast Neutron Detector Using 4He/CO2 and 4He/CO2/C4H10 Gas Mixtures
title_short Comparative Study of a GEM-based Fast Neutron Detector Using 4He/CO2 and 4He/CO2/C4H10 Gas Mixtures
title_full Comparative Study of a GEM-based Fast Neutron Detector Using 4He/CO2 and 4He/CO2/C4H10 Gas Mixtures
title_fullStr Comparative Study of a GEM-based Fast Neutron Detector Using 4He/CO2 and 4He/CO2/C4H10 Gas Mixtures
title_full_unstemmed Comparative Study of a GEM-based Fast Neutron Detector Using 4He/CO2 and 4He/CO2/C4H10 Gas Mixtures
title_sort comparative study of a gem-based fast neutron detector using 4he/co2 and 4he/co2/c4h10 gas mixtures
publisher Science Faculty of Chiang Mai University
publishDate 2019
url http://it.science.cmu.ac.th/ejournal/dl.php?journal_id=8494
http://cmuir.cmu.ac.th/jspui/handle/6653943832/63993
_version_ 1681425998670725120