Determination of Cyanide in Concrete Roofing Tiles by Differential Pulse Voltammetric Method
Differential pulse cathodic voltammetric technique with a hanging mercury drop electrode (HMDE) has been developed for the determination of cyanide in a water extract of concrete roofing tile samples. The sample was extracted with water for 24 h according to the TIS 535-2556 standard method. An aliq...
Saved in:
Main Authors: | , |
---|---|
Format: | บทความวารสาร |
Language: | English |
Published: |
Science Faculty of Chiang Mai University
2019
|
Online Access: | http://it.science.cmu.ac.th/ejournal/dl.php?journal_id=9665 http://cmuir.cmu.ac.th/jspui/handle/6653943832/64241 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
Language: | English |
id |
th-cmuir.6653943832-64241 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-642412019-05-07T09:59:54Z Determination of Cyanide in Concrete Roofing Tiles by Differential Pulse Voltammetric Method Jaroon Junsomboon Jaroon Jakmunee Differential pulse cathodic voltammetric technique with a hanging mercury drop electrode (HMDE) has been developed for the determination of cyanide in a water extract of concrete roofing tile samples. The sample was extracted with water for 24 h according to the TIS 535-2556 standard method. An aliquot of 5 mL of the extracted solution and 5 mL of electrolyte solution (0.2 M KOH + 0.2 M H3BO3) were put in a voltammetric cell, stirred at 2000 rpm, and purged with nitrogen gas for 3 min. Then, a constant potential of 0.00 V versus Ag/AgCl reference electrode was applied to the working electrode for 10 s; the differential pulse waveform was cathodically scanned from 0.0 to - 0.45 V for recording a voltammogram. Reduction peak current at peak potential of - 0.22 V vs Ag/AgCl electrode was proportional to cyanide concentration. Relative standard deviation for 11 replicate determinations of 0.04 mg L-1 CN- was 2.62%. Percentage recovery obtained by spiking 0.04 mg L-1 CN- to the sample solution was found to be 95%, and a detection limit of 0.001 mg L-1 was achieved. The developed method provides good sensitivity and selectivity, which is suitable for quality control of cyanide in the concrete roofing tile products, and it is simple, convenient operation, and low reagent consumption. 2019-05-07T09:59:54Z 2019-05-07T09:59:54Z 2018 บทความวารสาร 0125-2526 http://it.science.cmu.ac.th/ejournal/dl.php?journal_id=9665 http://cmuir.cmu.ac.th/jspui/handle/6653943832/64241 Eng Science Faculty of Chiang Mai University |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
language |
English |
description |
Differential pulse cathodic voltammetric technique with a hanging mercury drop electrode (HMDE) has been developed for the determination of cyanide in a water extract of concrete roofing tile samples. The sample was extracted with water for 24 h according to the TIS 535-2556 standard method. An aliquot of 5 mL of the extracted solution and 5 mL of electrolyte solution (0.2 M KOH + 0.2 M H3BO3) were put in a voltammetric cell, stirred at 2000 rpm, and purged with nitrogen gas for 3 min. Then, a constant potential of 0.00 V versus Ag/AgCl reference electrode was applied to the working electrode for 10 s; the differential pulse waveform was cathodically scanned from 0.0 to - 0.45 V for recording a voltammogram. Reduction peak current at peak potential of - 0.22 V vs Ag/AgCl electrode was proportional to cyanide concentration. Relative standard deviation for 11 replicate determinations of 0.04 mg L-1 CN- was 2.62%. Percentage recovery obtained by spiking 0.04 mg L-1 CN- to the sample solution was found to be 95%, and a detection limit of 0.001 mg L-1 was achieved. The developed method provides good sensitivity and selectivity, which is suitable for quality control of cyanide in the concrete roofing tile products, and it is simple, convenient operation, and low reagent consumption. |
format |
บทความวารสาร |
author |
Jaroon Junsomboon Jaroon Jakmunee |
spellingShingle |
Jaroon Junsomboon Jaroon Jakmunee Determination of Cyanide in Concrete Roofing Tiles by Differential Pulse Voltammetric Method |
author_facet |
Jaroon Junsomboon Jaroon Jakmunee |
author_sort |
Jaroon Junsomboon |
title |
Determination of Cyanide in Concrete Roofing Tiles by Differential Pulse Voltammetric Method |
title_short |
Determination of Cyanide in Concrete Roofing Tiles by Differential Pulse Voltammetric Method |
title_full |
Determination of Cyanide in Concrete Roofing Tiles by Differential Pulse Voltammetric Method |
title_fullStr |
Determination of Cyanide in Concrete Roofing Tiles by Differential Pulse Voltammetric Method |
title_full_unstemmed |
Determination of Cyanide in Concrete Roofing Tiles by Differential Pulse Voltammetric Method |
title_sort |
determination of cyanide in concrete roofing tiles by differential pulse voltammetric method |
publisher |
Science Faculty of Chiang Mai University |
publishDate |
2019 |
url |
http://it.science.cmu.ac.th/ejournal/dl.php?journal_id=9665 http://cmuir.cmu.ac.th/jspui/handle/6653943832/64241 |
_version_ |
1681426045020930048 |