Determination of Cyanide in Concrete Roofing Tiles by Differential Pulse Voltammetric Method

Differential pulse cathodic voltammetric technique with a hanging mercury drop electrode (HMDE) has been developed for the determination of cyanide in a water extract of concrete roofing tile samples. The sample was extracted with water for 24 h according to the TIS 535-2556 standard method. An aliq...

全面介紹

Saved in:
書目詳細資料
Main Authors: Jaroon Junsomboon, Jaroon Jakmunee
格式: บทความวารสาร
語言:English
出版: Science Faculty of Chiang Mai University 2019
在線閱讀:http://it.science.cmu.ac.th/ejournal/dl.php?journal_id=9665
http://cmuir.cmu.ac.th/jspui/handle/6653943832/64241
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
機構: Chiang Mai University
語言: English
id th-cmuir.6653943832-64241
record_format dspace
spelling th-cmuir.6653943832-642412019-05-07T09:59:54Z Determination of Cyanide in Concrete Roofing Tiles by Differential Pulse Voltammetric Method Jaroon Junsomboon Jaroon Jakmunee Differential pulse cathodic voltammetric technique with a hanging mercury drop electrode (HMDE) has been developed for the determination of cyanide in a water extract of concrete roofing tile samples. The sample was extracted with water for 24 h according to the TIS 535-2556 standard method. An aliquot of 5 mL of the extracted solution and 5 mL of electrolyte solution (0.2 M KOH + 0.2 M H3BO3) were put in a voltammetric cell, stirred at 2000 rpm, and purged with nitrogen gas for 3 min. Then, a constant potential of 0.00 V versus Ag/AgCl reference electrode was applied to the working electrode for 10 s; the differential pulse waveform was cathodically scanned from 0.0 to - 0.45 V for recording a voltammogram. Reduction peak current at peak potential of - 0.22 V vs Ag/AgCl electrode was proportional to cyanide concentration. Relative standard deviation for 11 replicate determinations of 0.04 mg L-1 CN- was 2.62%. Percentage recovery obtained by spiking 0.04 mg L-1 CN- to the sample solution was found to be 95%, and a detection limit of 0.001 mg L-1 was achieved. The developed method provides good sensitivity and selectivity, which is suitable for quality control of cyanide in the concrete roofing tile products, and it is simple, convenient operation, and low reagent consumption. 2019-05-07T09:59:54Z 2019-05-07T09:59:54Z 2018 บทความวารสาร 0125-2526 http://it.science.cmu.ac.th/ejournal/dl.php?journal_id=9665 http://cmuir.cmu.ac.th/jspui/handle/6653943832/64241 Eng Science Faculty of Chiang Mai University
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
language English
description Differential pulse cathodic voltammetric technique with a hanging mercury drop electrode (HMDE) has been developed for the determination of cyanide in a water extract of concrete roofing tile samples. The sample was extracted with water for 24 h according to the TIS 535-2556 standard method. An aliquot of 5 mL of the extracted solution and 5 mL of electrolyte solution (0.2 M KOH + 0.2 M H3BO3) were put in a voltammetric cell, stirred at 2000 rpm, and purged with nitrogen gas for 3 min. Then, a constant potential of 0.00 V versus Ag/AgCl reference electrode was applied to the working electrode for 10 s; the differential pulse waveform was cathodically scanned from 0.0 to - 0.45 V for recording a voltammogram. Reduction peak current at peak potential of - 0.22 V vs Ag/AgCl electrode was proportional to cyanide concentration. Relative standard deviation for 11 replicate determinations of 0.04 mg L-1 CN- was 2.62%. Percentage recovery obtained by spiking 0.04 mg L-1 CN- to the sample solution was found to be 95%, and a detection limit of 0.001 mg L-1 was achieved. The developed method provides good sensitivity and selectivity, which is suitable for quality control of cyanide in the concrete roofing tile products, and it is simple, convenient operation, and low reagent consumption.
format บทความวารสาร
author Jaroon Junsomboon
Jaroon Jakmunee
spellingShingle Jaroon Junsomboon
Jaroon Jakmunee
Determination of Cyanide in Concrete Roofing Tiles by Differential Pulse Voltammetric Method
author_facet Jaroon Junsomboon
Jaroon Jakmunee
author_sort Jaroon Junsomboon
title Determination of Cyanide in Concrete Roofing Tiles by Differential Pulse Voltammetric Method
title_short Determination of Cyanide in Concrete Roofing Tiles by Differential Pulse Voltammetric Method
title_full Determination of Cyanide in Concrete Roofing Tiles by Differential Pulse Voltammetric Method
title_fullStr Determination of Cyanide in Concrete Roofing Tiles by Differential Pulse Voltammetric Method
title_full_unstemmed Determination of Cyanide in Concrete Roofing Tiles by Differential Pulse Voltammetric Method
title_sort determination of cyanide in concrete roofing tiles by differential pulse voltammetric method
publisher Science Faculty of Chiang Mai University
publishDate 2019
url http://it.science.cmu.ac.th/ejournal/dl.php?journal_id=9665
http://cmuir.cmu.ac.th/jspui/handle/6653943832/64241
_version_ 1681426045020930048