© 2018 IEEE. While the utilization of a two-level voltage source inverter (VSI) with a single de supply fed ac loads such as ac motor drives, it also causes some problems, among which the common-mode voltage (CMV) cannot be ignored in drive systems, the mitigation or zero CMV control is necessary fo...

Full description

Saved in:
Bibliographic Details
Main Authors: Nuttawout Buarat, Yuttana Kumsuwan
Format: Conference Proceeding
Published: 2019
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85066630352&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/65593
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-65593
record_format dspace
spelling th-cmuir.6653943832-655932019-08-05T04:36:34Z Elimination of Common-Mode Voltage in Dual Two-Level Voltage Source Inverter Fed Open-End Load Using a Discontinuous SVM Technique Nuttawout Buarat Yuttana Kumsuwan Engineering © 2018 IEEE. While the utilization of a two-level voltage source inverter (VSI) with a single de supply fed ac loads such as ac motor drives, it also causes some problems, among which the common-mode voltage (CMV) cannot be ignored in drive systems, the mitigation or zero CMV control is necessary for proper operation. This paper proposes a discontinuous space vector modulation (SVM) technique to eliminate the CMV of a dual two-level VSI with two isolated de supplies fed open-end load applications. This technique uses five-segment switching sequence design with centralizing PWM scheme to generate the discontinuous modulating waves for both inverters, resulting in reduces the step and peak value of the CMV of each inverter and also is that it can cancel the CMV at the open-end load to zero. Simulation results validate the effectiveness of the proposed technique. 2019-08-05T04:36:34Z 2019-08-05T04:36:34Z 2019-05-09 Conference Proceeding 2-s2.0-85066630352 10.1109/IEECON.2018.8712224 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85066630352&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/65593
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Engineering
spellingShingle Engineering
Nuttawout Buarat
Yuttana Kumsuwan
Elimination of Common-Mode Voltage in Dual Two-Level Voltage Source Inverter Fed Open-End Load Using a Discontinuous SVM Technique
description © 2018 IEEE. While the utilization of a two-level voltage source inverter (VSI) with a single de supply fed ac loads such as ac motor drives, it also causes some problems, among which the common-mode voltage (CMV) cannot be ignored in drive systems, the mitigation or zero CMV control is necessary for proper operation. This paper proposes a discontinuous space vector modulation (SVM) technique to eliminate the CMV of a dual two-level VSI with two isolated de supplies fed open-end load applications. This technique uses five-segment switching sequence design with centralizing PWM scheme to generate the discontinuous modulating waves for both inverters, resulting in reduces the step and peak value of the CMV of each inverter and also is that it can cancel the CMV at the open-end load to zero. Simulation results validate the effectiveness of the proposed technique.
format Conference Proceeding
author Nuttawout Buarat
Yuttana Kumsuwan
author_facet Nuttawout Buarat
Yuttana Kumsuwan
author_sort Nuttawout Buarat
title Elimination of Common-Mode Voltage in Dual Two-Level Voltage Source Inverter Fed Open-End Load Using a Discontinuous SVM Technique
title_short Elimination of Common-Mode Voltage in Dual Two-Level Voltage Source Inverter Fed Open-End Load Using a Discontinuous SVM Technique
title_full Elimination of Common-Mode Voltage in Dual Two-Level Voltage Source Inverter Fed Open-End Load Using a Discontinuous SVM Technique
title_fullStr Elimination of Common-Mode Voltage in Dual Two-Level Voltage Source Inverter Fed Open-End Load Using a Discontinuous SVM Technique
title_full_unstemmed Elimination of Common-Mode Voltage in Dual Two-Level Voltage Source Inverter Fed Open-End Load Using a Discontinuous SVM Technique
title_sort elimination of common-mode voltage in dual two-level voltage source inverter fed open-end load using a discontinuous svm technique
publishDate 2019
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85066630352&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/65593
_version_ 1681426297813729280