Elimination of Common-Mode Voltage in Dual Two-Level Voltage Source Inverter Fed Open-End Load Using a Discontinuous SVM Technique
© 2018 IEEE. While the utilization of a two-level voltage source inverter (VSI) with a single de supply fed ac loads such as ac motor drives, it also causes some problems, among which the common-mode voltage (CMV) cannot be ignored in drive systems, the mitigation or zero CMV control is necessary fo...
Saved in:
Main Authors: | , |
---|---|
Format: | Conference Proceeding |
Published: |
2019
|
Subjects: | |
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85066630352&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/65593 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-65593 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-655932019-08-05T04:36:34Z Elimination of Common-Mode Voltage in Dual Two-Level Voltage Source Inverter Fed Open-End Load Using a Discontinuous SVM Technique Nuttawout Buarat Yuttana Kumsuwan Engineering © 2018 IEEE. While the utilization of a two-level voltage source inverter (VSI) with a single de supply fed ac loads such as ac motor drives, it also causes some problems, among which the common-mode voltage (CMV) cannot be ignored in drive systems, the mitigation or zero CMV control is necessary for proper operation. This paper proposes a discontinuous space vector modulation (SVM) technique to eliminate the CMV of a dual two-level VSI with two isolated de supplies fed open-end load applications. This technique uses five-segment switching sequence design with centralizing PWM scheme to generate the discontinuous modulating waves for both inverters, resulting in reduces the step and peak value of the CMV of each inverter and also is that it can cancel the CMV at the open-end load to zero. Simulation results validate the effectiveness of the proposed technique. 2019-08-05T04:36:34Z 2019-08-05T04:36:34Z 2019-05-09 Conference Proceeding 2-s2.0-85066630352 10.1109/IEECON.2018.8712224 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85066630352&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/65593 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
topic |
Engineering |
spellingShingle |
Engineering Nuttawout Buarat Yuttana Kumsuwan Elimination of Common-Mode Voltage in Dual Two-Level Voltage Source Inverter Fed Open-End Load Using a Discontinuous SVM Technique |
description |
© 2018 IEEE. While the utilization of a two-level voltage source inverter (VSI) with a single de supply fed ac loads such as ac motor drives, it also causes some problems, among which the common-mode voltage (CMV) cannot be ignored in drive systems, the mitigation or zero CMV control is necessary for proper operation. This paper proposes a discontinuous space vector modulation (SVM) technique to eliminate the CMV of a dual two-level VSI with two isolated de supplies fed open-end load applications. This technique uses five-segment switching sequence design with centralizing PWM scheme to generate the discontinuous modulating waves for both inverters, resulting in reduces the step and peak value of the CMV of each inverter and also is that it can cancel the CMV at the open-end load to zero. Simulation results validate the effectiveness of the proposed technique. |
format |
Conference Proceeding |
author |
Nuttawout Buarat Yuttana Kumsuwan |
author_facet |
Nuttawout Buarat Yuttana Kumsuwan |
author_sort |
Nuttawout Buarat |
title |
Elimination of Common-Mode Voltage in Dual Two-Level Voltage Source Inverter Fed Open-End Load Using a Discontinuous SVM Technique |
title_short |
Elimination of Common-Mode Voltage in Dual Two-Level Voltage Source Inverter Fed Open-End Load Using a Discontinuous SVM Technique |
title_full |
Elimination of Common-Mode Voltage in Dual Two-Level Voltage Source Inverter Fed Open-End Load Using a Discontinuous SVM Technique |
title_fullStr |
Elimination of Common-Mode Voltage in Dual Two-Level Voltage Source Inverter Fed Open-End Load Using a Discontinuous SVM Technique |
title_full_unstemmed |
Elimination of Common-Mode Voltage in Dual Two-Level Voltage Source Inverter Fed Open-End Load Using a Discontinuous SVM Technique |
title_sort |
elimination of common-mode voltage in dual two-level voltage source inverter fed open-end load using a discontinuous svm technique |
publishDate |
2019 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85066630352&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/65593 |
_version_ |
1681426297813729280 |