Determining the utility of a smartphone-based gait evaluation for possible use in concussion management

© 2019, © 2019 Informa UK Limited, trading as Taylor & Francis Group. Objectives: Our was objectives were to (1) assess the validity of a smartphone-based application to obtain spatiotemporal gait variables relative to an established movement monitoring system used previously to evaluate post-...

Full description

Saved in:
Bibliographic Details
Main Authors: David R. Howell, Vipul Lugade, Mikhail Taksir, William P. Meehan
Format: Journal
Published: 2019
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85068172181&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/65641
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
Description
Summary:© 2019, © 2019 Informa UK Limited, trading as Taylor & Francis Group. Objectives: Our was objectives were to (1) assess the validity of a smartphone-based application to obtain spatiotemporal gait variables relative to an established movement monitoring system used previously to evaluate post-concussion gait, and (2) determine the test-retest reliability of gait variables obtained with a smartphone. Methods: Twenty healthy participants (n = 14 females, mean age = 22.2, SD = 2.1 years) were assessed at two time points, approximately two weeks apart. Two measurement systems (inertial sensor system, smartphone application) acquired and analyzed single-task and dual-task spatio-temporal gait variables simultaneously. Our primary outcome measures were average walking speed (m/s), cadence (steps/min), and stride length (m) measured by the inertial sensor system and smartphone application. Results: Correlations between the systems were high to very high (Pearson r = 0.77–0.98) at both time points, with the exception of dual-task stride length at time 2 (Pearson r = 0.55). Bland-Altman analysis for average gait speed and cadence indicated the average disagreement between systems was close to zero, suggesting little evidence for systematic bias between acquisition systems. Test-retest consistency measures using the smartphone revealed high to very high reliability for all measurements (ICC = 0.81–0.95). Conclusions: Our results indicate that sensors within a smartphone are capable of measuring spatio-temporal gait variables similar to a validated three-sensor inertial sensor system in single-task and dual-task conditions, and that data are reliable across a two-week time interval. A smartphone-based application might allow clinicians to objectively evaluate gait in the management of concussion with high ease-of-use and a relatively low financial burden.