Monte Carlo MCNP-based simulation and radiation measurement of Yttrium-90 bremsstrahlung produced from radiation shielding apparatus

© Published under licence by IOP Publishing Ltd. Yttrium-90 (90Y) has been widely used in therapeutic nuclear medicine including in the selective internal radiation therapy with 90Y-microsphere. In the procedure 90Y source is protected within the radiation shielding apparatus made of perspex. Howeve...

Full description

Saved in:
Bibliographic Details
Main Authors: C. Onnomdee, C. Jumpee, J. Channuie, P. Sinkaew, K. Chuamsaamarkkee, P. Charoenphun
Format: Conference Proceeding
Published: 2019
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85067642190&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/65871
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-65871
record_format dspace
spelling th-cmuir.6653943832-658712019-08-05T04:43:15Z Monte Carlo MCNP-based simulation and radiation measurement of Yttrium-90 bremsstrahlung produced from radiation shielding apparatus C. Onnomdee C. Jumpee J. Channuie P. Sinkaew K. Chuamsaamarkkee P. Charoenphun Physics and Astronomy © Published under licence by IOP Publishing Ltd. Yttrium-90 (90Y) has been widely used in therapeutic nuclear medicine including in the selective internal radiation therapy with 90Y-microsphere. In the procedure 90Y source is protected within the radiation shielding apparatus made of perspex. However, bremsstrahlung radiation may be generated when 90Y interacts with matter. The aim of this study was to evaluate bremsstrahlung radiation produced from radiation shielding apparatus using a scintillation detector and Monte Carlo simulation. The 90Y source in glass vial was placed in the radiation shielding apparatus. Bremsstrahlung measurement and spectrum were performed and recorded using thallium-doped sodium iodide (NaI(Tl)) scintillation detector. Counting time and distance between the detector and apparatus were varied to obtain the optimal condition for bremsstrahlung measurement. Monte Carlo N-Particle (MCNP) 5 was used to simulate bremsstrahlung radiation with the same geometry used in the measurement. For experimental measurement results, the optimal distance and counting time were 10 cm and 120 s, respectively. Although the result of bremsstrahlung spectrum from the detector and simulation exhibited similar trend, markedly greater count rate was observed in simulations than in detector measurements. In conclusion, 90Y bremsstrahlung can be produced from radiation protection apparatus and this can be evaluated by either measurement or simulation. 2019-08-05T04:43:15Z 2019-08-05T04:43:15Z 2019-06-06 Conference Proceeding 17426596 17426588 2-s2.0-85067642190 10.1088/1742-6596/1248/1/012043 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85067642190&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/65871
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Physics and Astronomy
spellingShingle Physics and Astronomy
C. Onnomdee
C. Jumpee
J. Channuie
P. Sinkaew
K. Chuamsaamarkkee
P. Charoenphun
Monte Carlo MCNP-based simulation and radiation measurement of Yttrium-90 bremsstrahlung produced from radiation shielding apparatus
description © Published under licence by IOP Publishing Ltd. Yttrium-90 (90Y) has been widely used in therapeutic nuclear medicine including in the selective internal radiation therapy with 90Y-microsphere. In the procedure 90Y source is protected within the radiation shielding apparatus made of perspex. However, bremsstrahlung radiation may be generated when 90Y interacts with matter. The aim of this study was to evaluate bremsstrahlung radiation produced from radiation shielding apparatus using a scintillation detector and Monte Carlo simulation. The 90Y source in glass vial was placed in the radiation shielding apparatus. Bremsstrahlung measurement and spectrum were performed and recorded using thallium-doped sodium iodide (NaI(Tl)) scintillation detector. Counting time and distance between the detector and apparatus were varied to obtain the optimal condition for bremsstrahlung measurement. Monte Carlo N-Particle (MCNP) 5 was used to simulate bremsstrahlung radiation with the same geometry used in the measurement. For experimental measurement results, the optimal distance and counting time were 10 cm and 120 s, respectively. Although the result of bremsstrahlung spectrum from the detector and simulation exhibited similar trend, markedly greater count rate was observed in simulations than in detector measurements. In conclusion, 90Y bremsstrahlung can be produced from radiation protection apparatus and this can be evaluated by either measurement or simulation.
format Conference Proceeding
author C. Onnomdee
C. Jumpee
J. Channuie
P. Sinkaew
K. Chuamsaamarkkee
P. Charoenphun
author_facet C. Onnomdee
C. Jumpee
J. Channuie
P. Sinkaew
K. Chuamsaamarkkee
P. Charoenphun
author_sort C. Onnomdee
title Monte Carlo MCNP-based simulation and radiation measurement of Yttrium-90 bremsstrahlung produced from radiation shielding apparatus
title_short Monte Carlo MCNP-based simulation and radiation measurement of Yttrium-90 bremsstrahlung produced from radiation shielding apparatus
title_full Monte Carlo MCNP-based simulation and radiation measurement of Yttrium-90 bremsstrahlung produced from radiation shielding apparatus
title_fullStr Monte Carlo MCNP-based simulation and radiation measurement of Yttrium-90 bremsstrahlung produced from radiation shielding apparatus
title_full_unstemmed Monte Carlo MCNP-based simulation and radiation measurement of Yttrium-90 bremsstrahlung produced from radiation shielding apparatus
title_sort monte carlo mcnp-based simulation and radiation measurement of yttrium-90 bremsstrahlung produced from radiation shielding apparatus
publishDate 2019
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85067642190&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/65871
_version_ 1681426349611286528