Comparison between manual and (Semi-)automated analyses of esophageal diaphragm electromyography during endurance cycling in patients with COPD
Copyright © 2019 Dacha, Janssens, Rodrigues, Louvaris, Janssens, Gosselink and Langer. Background: Electrocardiogram (ECG) contamination is present in diaphragm electromyography (EMGdi) recordings. Obtaining EMGdi without ECG contamination is crucial for EMG amplitude analysis. Manually selecting EM...
Saved in:
Main Authors: | , , , , , , |
---|---|
Format: | Journal |
Published: |
2019
|
Subjects: | |
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85069894842&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/66609 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-66609 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-666092019-09-16T12:58:33Z Comparison between manual and (Semi-)automated analyses of esophageal diaphragm electromyography during endurance cycling in patients with COPD Sauwaluk Dacha Luc Janssens Antenor Rodrigues Zafeiris Louvaris Lotte Janssens Rik Gosselink Daniel Langer Biochemistry, Genetics and Molecular Biology Medicine Copyright © 2019 Dacha, Janssens, Rodrigues, Louvaris, Janssens, Gosselink and Langer. Background: Electrocardiogram (ECG) contamination is present in diaphragm electromyography (EMGdi) recordings. Obtaining EMGdi without ECG contamination is crucial for EMG amplitude analysis. Manually selecting EMGdi in between QRS complexes has been most commonly applied in recent years (manual method). We developed a semi-automated analysis method based on Least Mean Square Adaptive Filtering combined with a synchronously recorded separate ECG channel to remove ECG artifacts from the EMGdi signals. We hypothesized that this approach would shorten analysis duration and might minimize the potential for inter-rater disagreement. Aims: We aimed to evaluate agreement between the semi-automated method and the manual method and inter-rater reliability of the manual method. Methods: Electromyography signals of seven patients with COPD were recorded using an esophageal catheter during an exercise test on a cycle ergometer. Four patients subsequently participated in an inspiratory muscle training (IMT) program for 8 weeks. After IMT, the tests were repeated. EMGdi/EMGdiMax as obtained either manually by the two assessors or retrieved from the semi-automated method were compared. Results: Semi-automated EMGdi/EMGdiMax agreed well with values obtained by one of the two manual assessors (assessor 1) both at pre-intervention measurements (mean difference -0.5%, 95% CI: -19.6 to 18.6%) and for the pre/post IMT differences (mean difference 1.2%, 95% CI: -16.8 to 19.2%). Intra-class correlation coefficients between methods were 0.96 (95% CI: 0.94-0.97) at pre-intervention measurements and 0.78 (95% CI: 0.58-0.89) for pre/post IMT differences (both p < 0.001). EMGdi/EMGdiMax from assessor 2 was systematically lower than from assessor 1 and agreed less well with the semi-automated method both at pre-intervention measurements (mean difference: 9.3%, 95% CI: -11.4 to 29.9%) and for pre/post IMT differences (mean difference 7.0%, 95% CI: -20.4 to 34.4%). Analysis duration of the semi-automated method was significantly shorter (29 ± 9 min) than the manual method (82 ± 20 min, p < 0.001). Conclusion: The developed semi-automated method is more time efficient and will be less prone to inter-rater variability that was observed when applying the manual analysis method. It is, therefore, proposed as a new standard for objective EMGdi amplitude analyses in future studies. 2019-09-16T12:48:35Z 2019-09-16T12:48:35Z 2019-01-01 Journal 1664042X 2-s2.0-85069894842 10.3389/fphys.2019.00885 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85069894842&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/66609 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
topic |
Biochemistry, Genetics and Molecular Biology Medicine |
spellingShingle |
Biochemistry, Genetics and Molecular Biology Medicine Sauwaluk Dacha Luc Janssens Antenor Rodrigues Zafeiris Louvaris Lotte Janssens Rik Gosselink Daniel Langer Comparison between manual and (Semi-)automated analyses of esophageal diaphragm electromyography during endurance cycling in patients with COPD |
description |
Copyright © 2019 Dacha, Janssens, Rodrigues, Louvaris, Janssens, Gosselink and Langer. Background: Electrocardiogram (ECG) contamination is present in diaphragm electromyography (EMGdi) recordings. Obtaining EMGdi without ECG contamination is crucial for EMG amplitude analysis. Manually selecting EMGdi in between QRS complexes has been most commonly applied in recent years (manual method). We developed a semi-automated analysis method based on Least Mean Square Adaptive Filtering combined with a synchronously recorded separate ECG channel to remove ECG artifacts from the EMGdi signals. We hypothesized that this approach would shorten analysis duration and might minimize the potential for inter-rater disagreement. Aims: We aimed to evaluate agreement between the semi-automated method and the manual method and inter-rater reliability of the manual method. Methods: Electromyography signals of seven patients with COPD were recorded using an esophageal catheter during an exercise test on a cycle ergometer. Four patients subsequently participated in an inspiratory muscle training (IMT) program for 8 weeks. After IMT, the tests were repeated. EMGdi/EMGdiMax as obtained either manually by the two assessors or retrieved from the semi-automated method were compared. Results: Semi-automated EMGdi/EMGdiMax agreed well with values obtained by one of the two manual assessors (assessor 1) both at pre-intervention measurements (mean difference -0.5%, 95% CI: -19.6 to 18.6%) and for the pre/post IMT differences (mean difference 1.2%, 95% CI: -16.8 to 19.2%). Intra-class correlation coefficients between methods were 0.96 (95% CI: 0.94-0.97) at pre-intervention measurements and 0.78 (95% CI: 0.58-0.89) for pre/post IMT differences (both p < 0.001). EMGdi/EMGdiMax from assessor 2 was systematically lower than from assessor 1 and agreed less well with the semi-automated method both at pre-intervention measurements (mean difference: 9.3%, 95% CI: -11.4 to 29.9%) and for pre/post IMT differences (mean difference 7.0%, 95% CI: -20.4 to 34.4%). Analysis duration of the semi-automated method was significantly shorter (29 ± 9 min) than the manual method (82 ± 20 min, p < 0.001). Conclusion: The developed semi-automated method is more time efficient and will be less prone to inter-rater variability that was observed when applying the manual analysis method. It is, therefore, proposed as a new standard for objective EMGdi amplitude analyses in future studies. |
format |
Journal |
author |
Sauwaluk Dacha Luc Janssens Antenor Rodrigues Zafeiris Louvaris Lotte Janssens Rik Gosselink Daniel Langer |
author_facet |
Sauwaluk Dacha Luc Janssens Antenor Rodrigues Zafeiris Louvaris Lotte Janssens Rik Gosselink Daniel Langer |
author_sort |
Sauwaluk Dacha |
title |
Comparison between manual and (Semi-)automated analyses of esophageal diaphragm electromyography during endurance cycling in patients with COPD |
title_short |
Comparison between manual and (Semi-)automated analyses of esophageal diaphragm electromyography during endurance cycling in patients with COPD |
title_full |
Comparison between manual and (Semi-)automated analyses of esophageal diaphragm electromyography during endurance cycling in patients with COPD |
title_fullStr |
Comparison between manual and (Semi-)automated analyses of esophageal diaphragm electromyography during endurance cycling in patients with COPD |
title_full_unstemmed |
Comparison between manual and (Semi-)automated analyses of esophageal diaphragm electromyography during endurance cycling in patients with COPD |
title_sort |
comparison between manual and (semi-)automated analyses of esophageal diaphragm electromyography during endurance cycling in patients with copd |
publishDate |
2019 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85069894842&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/66609 |
_version_ |
1681426487245275136 |