Comparison between manual and (Semi-)automated analyses of esophageal diaphragm electromyography during endurance cycling in patients with COPD

Copyright © 2019 Dacha, Janssens, Rodrigues, Louvaris, Janssens, Gosselink and Langer. Background: Electrocardiogram (ECG) contamination is present in diaphragm electromyography (EMGdi) recordings. Obtaining EMGdi without ECG contamination is crucial for EMG amplitude analysis. Manually selecting EM...

Full description

Saved in:
Bibliographic Details
Main Authors: Sauwaluk Dacha, Luc Janssens, Antenor Rodrigues, Zafeiris Louvaris, Lotte Janssens, Rik Gosselink, Daniel Langer
Format: Journal
Published: 2019
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85069894842&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/66609
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-66609
record_format dspace
spelling th-cmuir.6653943832-666092019-09-16T12:58:33Z Comparison between manual and (Semi-)automated analyses of esophageal diaphragm electromyography during endurance cycling in patients with COPD Sauwaluk Dacha Luc Janssens Antenor Rodrigues Zafeiris Louvaris Lotte Janssens Rik Gosselink Daniel Langer Biochemistry, Genetics and Molecular Biology Medicine Copyright © 2019 Dacha, Janssens, Rodrigues, Louvaris, Janssens, Gosselink and Langer. Background: Electrocardiogram (ECG) contamination is present in diaphragm electromyography (EMGdi) recordings. Obtaining EMGdi without ECG contamination is crucial for EMG amplitude analysis. Manually selecting EMGdi in between QRS complexes has been most commonly applied in recent years (manual method). We developed a semi-automated analysis method based on Least Mean Square Adaptive Filtering combined with a synchronously recorded separate ECG channel to remove ECG artifacts from the EMGdi signals. We hypothesized that this approach would shorten analysis duration and might minimize the potential for inter-rater disagreement. Aims: We aimed to evaluate agreement between the semi-automated method and the manual method and inter-rater reliability of the manual method. Methods: Electromyography signals of seven patients with COPD were recorded using an esophageal catheter during an exercise test on a cycle ergometer. Four patients subsequently participated in an inspiratory muscle training (IMT) program for 8 weeks. After IMT, the tests were repeated. EMGdi/EMGdiMax as obtained either manually by the two assessors or retrieved from the semi-automated method were compared. Results: Semi-automated EMGdi/EMGdiMax agreed well with values obtained by one of the two manual assessors (assessor 1) both at pre-intervention measurements (mean difference -0.5%, 95% CI: -19.6 to 18.6%) and for the pre/post IMT differences (mean difference 1.2%, 95% CI: -16.8 to 19.2%). Intra-class correlation coefficients between methods were 0.96 (95% CI: 0.94-0.97) at pre-intervention measurements and 0.78 (95% CI: 0.58-0.89) for pre/post IMT differences (both p < 0.001). EMGdi/EMGdiMax from assessor 2 was systematically lower than from assessor 1 and agreed less well with the semi-automated method both at pre-intervention measurements (mean difference: 9.3%, 95% CI: -11.4 to 29.9%) and for pre/post IMT differences (mean difference 7.0%, 95% CI: -20.4 to 34.4%). Analysis duration of the semi-automated method was significantly shorter (29 ± 9 min) than the manual method (82 ± 20 min, p < 0.001). Conclusion: The developed semi-automated method is more time efficient and will be less prone to inter-rater variability that was observed when applying the manual analysis method. It is, therefore, proposed as a new standard for objective EMGdi amplitude analyses in future studies. 2019-09-16T12:48:35Z 2019-09-16T12:48:35Z 2019-01-01 Journal 1664042X 2-s2.0-85069894842 10.3389/fphys.2019.00885 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85069894842&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/66609
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Biochemistry, Genetics and Molecular Biology
Medicine
spellingShingle Biochemistry, Genetics and Molecular Biology
Medicine
Sauwaluk Dacha
Luc Janssens
Antenor Rodrigues
Zafeiris Louvaris
Lotte Janssens
Rik Gosselink
Daniel Langer
Comparison between manual and (Semi-)automated analyses of esophageal diaphragm electromyography during endurance cycling in patients with COPD
description Copyright © 2019 Dacha, Janssens, Rodrigues, Louvaris, Janssens, Gosselink and Langer. Background: Electrocardiogram (ECG) contamination is present in diaphragm electromyography (EMGdi) recordings. Obtaining EMGdi without ECG contamination is crucial for EMG amplitude analysis. Manually selecting EMGdi in between QRS complexes has been most commonly applied in recent years (manual method). We developed a semi-automated analysis method based on Least Mean Square Adaptive Filtering combined with a synchronously recorded separate ECG channel to remove ECG artifacts from the EMGdi signals. We hypothesized that this approach would shorten analysis duration and might minimize the potential for inter-rater disagreement. Aims: We aimed to evaluate agreement between the semi-automated method and the manual method and inter-rater reliability of the manual method. Methods: Electromyography signals of seven patients with COPD were recorded using an esophageal catheter during an exercise test on a cycle ergometer. Four patients subsequently participated in an inspiratory muscle training (IMT) program for 8 weeks. After IMT, the tests were repeated. EMGdi/EMGdiMax as obtained either manually by the two assessors or retrieved from the semi-automated method were compared. Results: Semi-automated EMGdi/EMGdiMax agreed well with values obtained by one of the two manual assessors (assessor 1) both at pre-intervention measurements (mean difference -0.5%, 95% CI: -19.6 to 18.6%) and for the pre/post IMT differences (mean difference 1.2%, 95% CI: -16.8 to 19.2%). Intra-class correlation coefficients between methods were 0.96 (95% CI: 0.94-0.97) at pre-intervention measurements and 0.78 (95% CI: 0.58-0.89) for pre/post IMT differences (both p < 0.001). EMGdi/EMGdiMax from assessor 2 was systematically lower than from assessor 1 and agreed less well with the semi-automated method both at pre-intervention measurements (mean difference: 9.3%, 95% CI: -11.4 to 29.9%) and for pre/post IMT differences (mean difference 7.0%, 95% CI: -20.4 to 34.4%). Analysis duration of the semi-automated method was significantly shorter (29 ± 9 min) than the manual method (82 ± 20 min, p < 0.001). Conclusion: The developed semi-automated method is more time efficient and will be less prone to inter-rater variability that was observed when applying the manual analysis method. It is, therefore, proposed as a new standard for objective EMGdi amplitude analyses in future studies.
format Journal
author Sauwaluk Dacha
Luc Janssens
Antenor Rodrigues
Zafeiris Louvaris
Lotte Janssens
Rik Gosselink
Daniel Langer
author_facet Sauwaluk Dacha
Luc Janssens
Antenor Rodrigues
Zafeiris Louvaris
Lotte Janssens
Rik Gosselink
Daniel Langer
author_sort Sauwaluk Dacha
title Comparison between manual and (Semi-)automated analyses of esophageal diaphragm electromyography during endurance cycling in patients with COPD
title_short Comparison between manual and (Semi-)automated analyses of esophageal diaphragm electromyography during endurance cycling in patients with COPD
title_full Comparison between manual and (Semi-)automated analyses of esophageal diaphragm electromyography during endurance cycling in patients with COPD
title_fullStr Comparison between manual and (Semi-)automated analyses of esophageal diaphragm electromyography during endurance cycling in patients with COPD
title_full_unstemmed Comparison between manual and (Semi-)automated analyses of esophageal diaphragm electromyography during endurance cycling in patients with COPD
title_sort comparison between manual and (semi-)automated analyses of esophageal diaphragm electromyography during endurance cycling in patients with copd
publishDate 2019
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85069894842&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/66609
_version_ 1681426487245275136