Five-year clinical efficacy and safety of contemporary thin-strut biodegradable polymer versus durable polymer drug-eluting stents: a systematic review and meta-analysis of 9 randomized controlled trials

© 2019, Japanese Association of Cardiovascular Intervention and Therapeutics. Very long-term data of the biodegradable polymer drug-eluting stents (BP-DES) in comparison with the contemporary durable polymer DES (DP-DES) are still to be investigated. We aimed to investigate the very long-term clinic...

Full description

Saved in:
Bibliographic Details
Main Authors: Tomoaki Kobayashi, Yohei Sotomi, Satoshi Suzuki, Pannipa Suwannasom, Shimpei Nakatani, Yoshihiro Morino, Junya Ako, Ken Kozuma, Atsushi Hirayama, Yasushi Sakata, Yoshiharu Higuchi
Format: Journal
Published: 2019
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85070800200&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/66730
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-66730
record_format dspace
spelling th-cmuir.6653943832-667302019-09-16T12:58:31Z Five-year clinical efficacy and safety of contemporary thin-strut biodegradable polymer versus durable polymer drug-eluting stents: a systematic review and meta-analysis of 9 randomized controlled trials Tomoaki Kobayashi Yohei Sotomi Satoshi Suzuki Pannipa Suwannasom Shimpei Nakatani Yoshihiro Morino Junya Ako Ken Kozuma Atsushi Hirayama Yasushi Sakata Yoshiharu Higuchi Medicine © 2019, Japanese Association of Cardiovascular Intervention and Therapeutics. Very long-term data of the biodegradable polymer drug-eluting stents (BP-DES) in comparison with the contemporary durable polymer DES (DP-DES) are still to be investigated. We aimed to investigate the very long-term clinical performance of contemporary BP-DES against the DP-DES. We performed a systematic review to evaluate very long-term clinical outcomes of BP-DES versus DP-DES. Inclusion criteria were randomized design comparing BP-DES against DP-DES and follow-up duration ≥ 36 months. MEDLINE, EMBASE, and CENTRAL without restricting language or publication status were searched up to December 2018. The primary efficacy and safety endpoints were target lesion failure (TLF; a composite of cardiac death, target vessel myocardial infarction and ischemia-driven target lesion revascularization) and definite/probable stent thrombosis (ST), respectively. Primary analysis was done for the contemporary thin-strut BP- and DP-DES (strut thickness < 100 µm). A total of 9 trials comprising 10,699 patients (BP-DES, n = 6241 versus DP-DES, n = 4458) were analyzed. The mean follow-up duration was 63 months. No significant difference was found in TLF [Odds ratio (95% CI) 1.04 (0.89–1.21)] and definite/probable ST (odds ratio (95% CI) 0.78 (0.59–1.01)] between the BP- and DP-DESs. The present meta-analysis suggested that the contemporary thin-strut BP- and DP-DES have similar efficacy and safety profile at 5-year follow-up. Clinical trial registration PROSPERO; CRD42018101983 https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=101983. 2019-09-16T12:58:31Z 2019-09-16T12:58:31Z 2019-01-01 Journal 18684297 18684300 2-s2.0-85070800200 10.1007/s12928-019-00613-w https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85070800200&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/66730
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Medicine
spellingShingle Medicine
Tomoaki Kobayashi
Yohei Sotomi
Satoshi Suzuki
Pannipa Suwannasom
Shimpei Nakatani
Yoshihiro Morino
Junya Ako
Ken Kozuma
Atsushi Hirayama
Yasushi Sakata
Yoshiharu Higuchi
Five-year clinical efficacy and safety of contemporary thin-strut biodegradable polymer versus durable polymer drug-eluting stents: a systematic review and meta-analysis of 9 randomized controlled trials
description © 2019, Japanese Association of Cardiovascular Intervention and Therapeutics. Very long-term data of the biodegradable polymer drug-eluting stents (BP-DES) in comparison with the contemporary durable polymer DES (DP-DES) are still to be investigated. We aimed to investigate the very long-term clinical performance of contemporary BP-DES against the DP-DES. We performed a systematic review to evaluate very long-term clinical outcomes of BP-DES versus DP-DES. Inclusion criteria were randomized design comparing BP-DES against DP-DES and follow-up duration ≥ 36 months. MEDLINE, EMBASE, and CENTRAL without restricting language or publication status were searched up to December 2018. The primary efficacy and safety endpoints were target lesion failure (TLF; a composite of cardiac death, target vessel myocardial infarction and ischemia-driven target lesion revascularization) and definite/probable stent thrombosis (ST), respectively. Primary analysis was done for the contemporary thin-strut BP- and DP-DES (strut thickness < 100 µm). A total of 9 trials comprising 10,699 patients (BP-DES, n = 6241 versus DP-DES, n = 4458) were analyzed. The mean follow-up duration was 63 months. No significant difference was found in TLF [Odds ratio (95% CI) 1.04 (0.89–1.21)] and definite/probable ST (odds ratio (95% CI) 0.78 (0.59–1.01)] between the BP- and DP-DESs. The present meta-analysis suggested that the contemporary thin-strut BP- and DP-DES have similar efficacy and safety profile at 5-year follow-up. Clinical trial registration PROSPERO; CRD42018101983 https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=101983.
format Journal
author Tomoaki Kobayashi
Yohei Sotomi
Satoshi Suzuki
Pannipa Suwannasom
Shimpei Nakatani
Yoshihiro Morino
Junya Ako
Ken Kozuma
Atsushi Hirayama
Yasushi Sakata
Yoshiharu Higuchi
author_facet Tomoaki Kobayashi
Yohei Sotomi
Satoshi Suzuki
Pannipa Suwannasom
Shimpei Nakatani
Yoshihiro Morino
Junya Ako
Ken Kozuma
Atsushi Hirayama
Yasushi Sakata
Yoshiharu Higuchi
author_sort Tomoaki Kobayashi
title Five-year clinical efficacy and safety of contemporary thin-strut biodegradable polymer versus durable polymer drug-eluting stents: a systematic review and meta-analysis of 9 randomized controlled trials
title_short Five-year clinical efficacy and safety of contemporary thin-strut biodegradable polymer versus durable polymer drug-eluting stents: a systematic review and meta-analysis of 9 randomized controlled trials
title_full Five-year clinical efficacy and safety of contemporary thin-strut biodegradable polymer versus durable polymer drug-eluting stents: a systematic review and meta-analysis of 9 randomized controlled trials
title_fullStr Five-year clinical efficacy and safety of contemporary thin-strut biodegradable polymer versus durable polymer drug-eluting stents: a systematic review and meta-analysis of 9 randomized controlled trials
title_full_unstemmed Five-year clinical efficacy and safety of contemporary thin-strut biodegradable polymer versus durable polymer drug-eluting stents: a systematic review and meta-analysis of 9 randomized controlled trials
title_sort five-year clinical efficacy and safety of contemporary thin-strut biodegradable polymer versus durable polymer drug-eluting stents: a systematic review and meta-analysis of 9 randomized controlled trials
publishDate 2019
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85070800200&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/66730
_version_ 1681426509563166720