Flow-based systems for rapid and high-precision enzyme kinetics studies
Enzyme kinetics studies normally focus on the initial rate of enzymatic reaction. However, the manual operation of steps of the conventional enzyme kinetics method has some drawbacks. Errors can result from the imprecise time control and time necessary for manual changing the reaction cuvettes into...
Saved in:
Main Authors: | , |
---|---|
Format: | Review |
Language: | English |
Published: |
2014
|
Online Access: | http://www.scopus.com/inward/record.url?eid=2-s2.0-84864998138&partnerID=40&md5=c6bfa28652618df61989896525d8e9c0 http://cmuir.cmu.ac.th/handle/6653943832/6727 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
Language: | English |
id |
th-cmuir.6653943832-6727 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-67272014-08-30T03:51:09Z Flow-based systems for rapid and high-precision enzyme kinetics studies Hartwell S.K. Grudpan K. Enzyme kinetics studies normally focus on the initial rate of enzymatic reaction. However, the manual operation of steps of the conventional enzyme kinetics method has some drawbacks. Errors can result from the imprecise time control and time necessary for manual changing the reaction cuvettes into and out of the detector. By using the automatic flow-based analytical systems, enzyme kinetics studies can be carried out at real-time initial rate avoiding the potential errors inherent in manual operation. Flow-based systems have been developed to provide rapid, low-volume, and high-precision analyses that effectively replace the many tedious and high volume requirements of conventional wet chemistry analyses. This article presents various arrangements of flow-based techniques and their potential use in future enzyme kinetics applications. © Copyright 2012 Supaporn Kradtap Hartwell and Kate Grudpan. 2014-08-30T03:51:09Z 2014-08-30T03:51:09Z 2012 Review 20908865 10.1155/2012/450716 http://www.scopus.com/inward/record.url?eid=2-s2.0-84864998138&partnerID=40&md5=c6bfa28652618df61989896525d8e9c0 http://cmuir.cmu.ac.th/handle/6653943832/6727 English |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
language |
English |
description |
Enzyme kinetics studies normally focus on the initial rate of enzymatic reaction. However, the manual operation of steps of the conventional enzyme kinetics method has some drawbacks. Errors can result from the imprecise time control and time necessary for manual changing the reaction cuvettes into and out of the detector. By using the automatic flow-based analytical systems, enzyme kinetics studies can be carried out at real-time initial rate avoiding the potential errors inherent in manual operation. Flow-based systems have been developed to provide rapid, low-volume, and high-precision analyses that effectively replace the many tedious and high volume requirements of conventional wet chemistry analyses. This article presents various arrangements of flow-based techniques and their potential use in future enzyme kinetics applications. © Copyright 2012 Supaporn Kradtap Hartwell and Kate Grudpan. |
format |
Review |
author |
Hartwell S.K. Grudpan K. |
spellingShingle |
Hartwell S.K. Grudpan K. Flow-based systems for rapid and high-precision enzyme kinetics studies |
author_facet |
Hartwell S.K. Grudpan K. |
author_sort |
Hartwell S.K. |
title |
Flow-based systems for rapid and high-precision enzyme kinetics studies |
title_short |
Flow-based systems for rapid and high-precision enzyme kinetics studies |
title_full |
Flow-based systems for rapid and high-precision enzyme kinetics studies |
title_fullStr |
Flow-based systems for rapid and high-precision enzyme kinetics studies |
title_full_unstemmed |
Flow-based systems for rapid and high-precision enzyme kinetics studies |
title_sort |
flow-based systems for rapid and high-precision enzyme kinetics studies |
publishDate |
2014 |
url |
http://www.scopus.com/inward/record.url?eid=2-s2.0-84864998138&partnerID=40&md5=c6bfa28652618df61989896525d8e9c0 http://cmuir.cmu.ac.th/handle/6653943832/6727 |
_version_ |
1681420667907473408 |