Sex determination in Northern Thai from crania by using computer-aided design software and conventional caliper methods
© 2018 Toonlanat Thuanthong, Paiwan Sudwan, published by Sciendo. Identification of sex from skeletal remains is an essential step in forensic anthropology. The skull is the second choice, after the pelvis, to estimate sex by osteometric methods. To evaluate the process of identification of sex in N...
Saved in:
Main Authors: | , |
---|---|
Format: | Journal |
Published: |
2020
|
Subjects: | |
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85072701393&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/67615 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-67615 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-676152020-04-02T14:56:41Z Sex determination in Northern Thai from crania by using computer-aided design software and conventional caliper methods Toonlanat Thuanthong Paiwan Sudwan Biochemistry, Genetics and Molecular Biology © 2018 Toonlanat Thuanthong, Paiwan Sudwan, published by Sciendo. Identification of sex from skeletal remains is an essential step in forensic anthropology. The skull is the second choice, after the pelvis, to estimate sex by osteometric methods. To evaluate the process of identification of sex in Northern Thai from crania by using computer-aided design (AutoCAD) software and conventional caliper methods. Dry skulls of 86 men and 74 women were examined. AutoCAD software and digital calipers were used to measure dimensions. Eleven of the 15 parameters were created for this study. Men are significantly larger than women in all parameters, except in the nasospinale-prosthion measurement. There were no significant differences in the intraobserver error test and between the AutoCAD and digital caliper measurements. The logistic regression analysis yielded a sex classification accuracy rate of 92.9% in men, 93.4% in women, and 93.1% of overall accuracy for AutoCAD software. When using digital calipers, there was an accuracy rate of 89.3% in men, 94.7% in women, and 91.9% for overall accuracy. AutoCAD software is a reliable method to predict the sex and provide high accuracy in sex determination from crania. 2020-04-02T14:56:41Z 2020-04-02T14:56:41Z 2019-09-20 Journal 1875855X 19057415 2-s2.0-85072701393 10.1515/abm-2019-0008 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85072701393&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/67615 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
topic |
Biochemistry, Genetics and Molecular Biology |
spellingShingle |
Biochemistry, Genetics and Molecular Biology Toonlanat Thuanthong Paiwan Sudwan Sex determination in Northern Thai from crania by using computer-aided design software and conventional caliper methods |
description |
© 2018 Toonlanat Thuanthong, Paiwan Sudwan, published by Sciendo. Identification of sex from skeletal remains is an essential step in forensic anthropology. The skull is the second choice, after the pelvis, to estimate sex by osteometric methods. To evaluate the process of identification of sex in Northern Thai from crania by using computer-aided design (AutoCAD) software and conventional caliper methods. Dry skulls of 86 men and 74 women were examined. AutoCAD software and digital calipers were used to measure dimensions. Eleven of the 15 parameters were created for this study. Men are significantly larger than women in all parameters, except in the nasospinale-prosthion measurement. There were no significant differences in the intraobserver error test and between the AutoCAD and digital caliper measurements. The logistic regression analysis yielded a sex classification accuracy rate of 92.9% in men, 93.4% in women, and 93.1% of overall accuracy for AutoCAD software. When using digital calipers, there was an accuracy rate of 89.3% in men, 94.7% in women, and 91.9% for overall accuracy. AutoCAD software is a reliable method to predict the sex and provide high accuracy in sex determination from crania. |
format |
Journal |
author |
Toonlanat Thuanthong Paiwan Sudwan |
author_facet |
Toonlanat Thuanthong Paiwan Sudwan |
author_sort |
Toonlanat Thuanthong |
title |
Sex determination in Northern Thai from crania by using computer-aided design software and conventional caliper methods |
title_short |
Sex determination in Northern Thai from crania by using computer-aided design software and conventional caliper methods |
title_full |
Sex determination in Northern Thai from crania by using computer-aided design software and conventional caliper methods |
title_fullStr |
Sex determination in Northern Thai from crania by using computer-aided design software and conventional caliper methods |
title_full_unstemmed |
Sex determination in Northern Thai from crania by using computer-aided design software and conventional caliper methods |
title_sort |
sex determination in northern thai from crania by using computer-aided design software and conventional caliper methods |
publishDate |
2020 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85072701393&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/67615 |
_version_ |
1681426668253609984 |