Application of smartphone as a digital image colorimetric detector for batch and flow-based acid-base titration

© 2019, Chiang Mai University. All rights reserved. In this research, we have developed the batch and flow-based system of titrimetric analysis by using a mobile phone as a detector. The digital image colorimetric detection system was set up with economic devices and to be easy to use by taking phot...

Full description

Saved in:
Bibliographic Details
Main Authors: Janejira Chanla, Miki Kanna, Jaroon Jakmunee, Sarawut Somnam
Format: Journal
Published: 2020
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85073740914&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/67635
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-67635
record_format dspace
spelling th-cmuir.6653943832-676352020-04-02T15:19:37Z Application of smartphone as a digital image colorimetric detector for batch and flow-based acid-base titration Janejira Chanla Miki Kanna Jaroon Jakmunee Sarawut Somnam Biochemistry, Genetics and Molecular Biology Chemistry Materials Science Mathematics Physics and Astronomy © 2019, Chiang Mai University. All rights reserved. In this research, we have developed the batch and flow-based system of titrimetric analysis by using a mobile phone as a detector. The digital image colorimetric detection system was set up with economic devices and to be easy to use by taking photograph with mobile phone camera, then the RGB signals were read from the RGB color picker application to calculate the RGB-based value and plot titration curve for evaluating the equivalence point. This method was applied to analyze samples of acid-base on daily basis, compared with the potentiometric and photometric titrations that using pH meter and spectrophotometer as a detector, respectively. The method was highly reproducible with the relative standard deviation of 1.14 % (n=11) for 0.5 %w/v of acetic acid standard solution. The proposed method was applied to the determination of acetic acid in vinegar and titratable acidity in fruit juices. Concentrations of acetic acid were found to be in a range of 5.23-5.35 %w/v. Concentrations of titratable acidity in the juice samples were found to be in a range of 0.27-0.50 %w/v. Thereafter, an analytical application involving the determination of the total alkalinity in mineral waters was performed, and it was found in the range of 11.50-18.50 mg/L of CaCO3 which were in good agreement with the results obtained from the standard method at the 95 % confidence level. 2020-04-02T14:58:23Z 2020-04-02T14:58:23Z 2019-01-01 Journal 01252526 2-s2.0-85073740914 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85073740914&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/67635
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Biochemistry, Genetics and Molecular Biology
Chemistry
Materials Science
Mathematics
Physics and Astronomy
spellingShingle Biochemistry, Genetics and Molecular Biology
Chemistry
Materials Science
Mathematics
Physics and Astronomy
Janejira Chanla
Miki Kanna
Jaroon Jakmunee
Sarawut Somnam
Application of smartphone as a digital image colorimetric detector for batch and flow-based acid-base titration
description © 2019, Chiang Mai University. All rights reserved. In this research, we have developed the batch and flow-based system of titrimetric analysis by using a mobile phone as a detector. The digital image colorimetric detection system was set up with economic devices and to be easy to use by taking photograph with mobile phone camera, then the RGB signals were read from the RGB color picker application to calculate the RGB-based value and plot titration curve for evaluating the equivalence point. This method was applied to analyze samples of acid-base on daily basis, compared with the potentiometric and photometric titrations that using pH meter and spectrophotometer as a detector, respectively. The method was highly reproducible with the relative standard deviation of 1.14 % (n=11) for 0.5 %w/v of acetic acid standard solution. The proposed method was applied to the determination of acetic acid in vinegar and titratable acidity in fruit juices. Concentrations of acetic acid were found to be in a range of 5.23-5.35 %w/v. Concentrations of titratable acidity in the juice samples were found to be in a range of 0.27-0.50 %w/v. Thereafter, an analytical application involving the determination of the total alkalinity in mineral waters was performed, and it was found in the range of 11.50-18.50 mg/L of CaCO3 which were in good agreement with the results obtained from the standard method at the 95 % confidence level.
format Journal
author Janejira Chanla
Miki Kanna
Jaroon Jakmunee
Sarawut Somnam
author_facet Janejira Chanla
Miki Kanna
Jaroon Jakmunee
Sarawut Somnam
author_sort Janejira Chanla
title Application of smartphone as a digital image colorimetric detector for batch and flow-based acid-base titration
title_short Application of smartphone as a digital image colorimetric detector for batch and flow-based acid-base titration
title_full Application of smartphone as a digital image colorimetric detector for batch and flow-based acid-base titration
title_fullStr Application of smartphone as a digital image colorimetric detector for batch and flow-based acid-base titration
title_full_unstemmed Application of smartphone as a digital image colorimetric detector for batch and flow-based acid-base titration
title_sort application of smartphone as a digital image colorimetric detector for batch and flow-based acid-base titration
publishDate 2020
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85073740914&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/67635
_version_ 1681426671857565696