Optimal operation of battery energy storage system in smart grid for reducing tap changer operation under photovoltaic fluctuation using cuckoo search
© 2019 IEEE. Renewable energy sources, especially photovoltaic (PV), have grown significantly and become important sources for power generation in distribution systems. However, the PV power generation is fluctuated by cloud movement, weather conditions, and wind speed which directly affect the exce...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Conference Proceeding |
Published: |
2020
|
Subjects: | |
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85072322373&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/67740 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-67740 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-677402020-04-02T15:05:23Z Optimal operation of battery energy storage system in smart grid for reducing tap changer operation under photovoltaic fluctuation using cuckoo search Keerachat Tantrapon Peerapol Jirapong Panida Thararak Kannathat Mansuwan Computer Science Energy Engineering © 2019 IEEE. Renewable energy sources, especially photovoltaic (PV), have grown significantly and become important sources for power generation in distribution systems. However, the PV power generation is fluctuated by cloud movement, weather conditions, and wind speed which directly affect the excessive operation of voltage regulation devices such as the on load tap changer (OLTC). This excessive operation will decrease the expected life cycle and increase maintenance requirements. This paper proposed an optional operation of the battery energy storage system (BESS) in microgrid by optimizing BESS active and reactive power with Cuckoo Search optimization (CSo). The main objective aims to minimize the OLTC tap operation under PV fluctuation. The CSO is implemented in MATLAB while DIgSILENT PowerFactory is used for load flow evaluation. Simulation case studies are performed using system data from the Mae Sa Riang microgrid in Thailand. Results show that the optimal operation of BESS using CSO can effectively reduce the number of OLTC tap operations in microgrid when compared to the results with the base case and microgrid controller. 2020-04-02T15:02:05Z 2020-04-02T15:02:05Z 2019-06-01 Conference Proceeding 2-s2.0-85072322373 10.1109/PTC.2019.8810774 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85072322373&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/67740 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
topic |
Computer Science Energy Engineering |
spellingShingle |
Computer Science Energy Engineering Keerachat Tantrapon Peerapol Jirapong Panida Thararak Kannathat Mansuwan Optimal operation of battery energy storage system in smart grid for reducing tap changer operation under photovoltaic fluctuation using cuckoo search |
description |
© 2019 IEEE. Renewable energy sources, especially photovoltaic (PV), have grown significantly and become important sources for power generation in distribution systems. However, the PV power generation is fluctuated by cloud movement, weather conditions, and wind speed which directly affect the excessive operation of voltage regulation devices such as the on load tap changer (OLTC). This excessive operation will decrease the expected life cycle and increase maintenance requirements. This paper proposed an optional operation of the battery energy storage system (BESS) in microgrid by optimizing BESS active and reactive power with Cuckoo Search optimization (CSo). The main objective aims to minimize the OLTC tap operation under PV fluctuation. The CSO is implemented in MATLAB while DIgSILENT PowerFactory is used for load flow evaluation. Simulation case studies are performed using system data from the Mae Sa Riang microgrid in Thailand. Results show that the optimal operation of BESS using CSO can effectively reduce the number of OLTC tap operations in microgrid when compared to the results with the base case and microgrid controller. |
format |
Conference Proceeding |
author |
Keerachat Tantrapon Peerapol Jirapong Panida Thararak Kannathat Mansuwan |
author_facet |
Keerachat Tantrapon Peerapol Jirapong Panida Thararak Kannathat Mansuwan |
author_sort |
Keerachat Tantrapon |
title |
Optimal operation of battery energy storage system in smart grid for reducing tap changer operation under photovoltaic fluctuation using cuckoo search |
title_short |
Optimal operation of battery energy storage system in smart grid for reducing tap changer operation under photovoltaic fluctuation using cuckoo search |
title_full |
Optimal operation of battery energy storage system in smart grid for reducing tap changer operation under photovoltaic fluctuation using cuckoo search |
title_fullStr |
Optimal operation of battery energy storage system in smart grid for reducing tap changer operation under photovoltaic fluctuation using cuckoo search |
title_full_unstemmed |
Optimal operation of battery energy storage system in smart grid for reducing tap changer operation under photovoltaic fluctuation using cuckoo search |
title_sort |
optimal operation of battery energy storage system in smart grid for reducing tap changer operation under photovoltaic fluctuation using cuckoo search |
publishDate |
2020 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85072322373&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/67740 |
_version_ |
1681426691033923584 |