Lysosomes of cancerous and normal cells in response to low-energy/low-dose medical diagnostic X-rays

© 2019, Ibn Sina Trust. All rights reserved. Background: Low-energy/low-dose ionizing radiation is increasingly being used in medical diagnosis, yet the effects of low-energy/low-dose medical diagnostic X-rays on biological systems remains a mystery. Thus, the aim of this present study is to determi...

Full description

Saved in:
Bibliographic Details
Main Authors: Montree Tungjai, Nuttakan Tubthaing, Suchart Kothan
Format: Journal
Published: 2020
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85073443621&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/67970
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-67970
record_format dspace
spelling th-cmuir.6653943832-679702020-04-02T15:12:44Z Lysosomes of cancerous and normal cells in response to low-energy/low-dose medical diagnostic X-rays Montree Tungjai Nuttakan Tubthaing Suchart Kothan Medicine © 2019, Ibn Sina Trust. All rights reserved. Background: Low-energy/low-dose ionizing radiation is increasingly being used in medical diagnosis, yet the effects of low-energy/low-dose medical diagnostic X-rays on biological systems remains a mystery. Thus, the aim of this present study is to determine the characteristics of lysosomes of cancerous and normal cells in response to low-energy/low-dose medical diagnostic X-rays. Methods and materials: Three cell lines composed of peripheral blood mononuclear cells (PBMCs), adriamycin-sensitive erythroleukemia cells (K562), and adriamycin-resistant erythroleukemia cells (K562/adr), were all exposed to low-energy/low-dose medical diagnostic X-rays that operated at 50, 70, and 100 kV, and 100 mAs for obtaining radiation doses at 0.03, 0.07, and 0.10 mGy, respectively. Accumulation of acridine orange in the lysosomes of each cell line was determined using flow cytometry completed at 4 and 6 hours-post irradiation. Results: The data showed an increase in fluorescence intensity of acridine orange in three irradiated cells line at 4 hours post-irradiation, but this intensity did not change at 6 hours post-irradiation when compared to that of corresponding non-irradiated cells. Conclusion: This finding suggests that changes in lysosomes might be a response to low-energy/low-dose medical diagnostic X-rays. 2020-04-02T15:12:44Z 2020-04-02T15:12:44Z 2019-09-09 Journal 20760299 22234721 2-s2.0-85073443621 10.3329/bjms.v18i4.42915 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85073443621&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/67970
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Medicine
spellingShingle Medicine
Montree Tungjai
Nuttakan Tubthaing
Suchart Kothan
Lysosomes of cancerous and normal cells in response to low-energy/low-dose medical diagnostic X-rays
description © 2019, Ibn Sina Trust. All rights reserved. Background: Low-energy/low-dose ionizing radiation is increasingly being used in medical diagnosis, yet the effects of low-energy/low-dose medical diagnostic X-rays on biological systems remains a mystery. Thus, the aim of this present study is to determine the characteristics of lysosomes of cancerous and normal cells in response to low-energy/low-dose medical diagnostic X-rays. Methods and materials: Three cell lines composed of peripheral blood mononuclear cells (PBMCs), adriamycin-sensitive erythroleukemia cells (K562), and adriamycin-resistant erythroleukemia cells (K562/adr), were all exposed to low-energy/low-dose medical diagnostic X-rays that operated at 50, 70, and 100 kV, and 100 mAs for obtaining radiation doses at 0.03, 0.07, and 0.10 mGy, respectively. Accumulation of acridine orange in the lysosomes of each cell line was determined using flow cytometry completed at 4 and 6 hours-post irradiation. Results: The data showed an increase in fluorescence intensity of acridine orange in three irradiated cells line at 4 hours post-irradiation, but this intensity did not change at 6 hours post-irradiation when compared to that of corresponding non-irradiated cells. Conclusion: This finding suggests that changes in lysosomes might be a response to low-energy/low-dose medical diagnostic X-rays.
format Journal
author Montree Tungjai
Nuttakan Tubthaing
Suchart Kothan
author_facet Montree Tungjai
Nuttakan Tubthaing
Suchart Kothan
author_sort Montree Tungjai
title Lysosomes of cancerous and normal cells in response to low-energy/low-dose medical diagnostic X-rays
title_short Lysosomes of cancerous and normal cells in response to low-energy/low-dose medical diagnostic X-rays
title_full Lysosomes of cancerous and normal cells in response to low-energy/low-dose medical diagnostic X-rays
title_fullStr Lysosomes of cancerous and normal cells in response to low-energy/low-dose medical diagnostic X-rays
title_full_unstemmed Lysosomes of cancerous and normal cells in response to low-energy/low-dose medical diagnostic X-rays
title_sort lysosomes of cancerous and normal cells in response to low-energy/low-dose medical diagnostic x-rays
publishDate 2020
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85073443621&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/67970
_version_ 1681426733755006976