Lysosomes of cancerous and normal cells in response to low-energy/low-dose medical diagnostic X-rays
© 2019, Ibn Sina Trust. All rights reserved. Background: Low-energy/low-dose ionizing radiation is increasingly being used in medical diagnosis, yet the effects of low-energy/low-dose medical diagnostic X-rays on biological systems remains a mystery. Thus, the aim of this present study is to determi...
Saved in:
Main Authors: | , , |
---|---|
Format: | Journal |
Published: |
2020
|
Subjects: | |
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85073443621&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/67970 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-67970 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-679702020-04-02T15:12:44Z Lysosomes of cancerous and normal cells in response to low-energy/low-dose medical diagnostic X-rays Montree Tungjai Nuttakan Tubthaing Suchart Kothan Medicine © 2019, Ibn Sina Trust. All rights reserved. Background: Low-energy/low-dose ionizing radiation is increasingly being used in medical diagnosis, yet the effects of low-energy/low-dose medical diagnostic X-rays on biological systems remains a mystery. Thus, the aim of this present study is to determine the characteristics of lysosomes of cancerous and normal cells in response to low-energy/low-dose medical diagnostic X-rays. Methods and materials: Three cell lines composed of peripheral blood mononuclear cells (PBMCs), adriamycin-sensitive erythroleukemia cells (K562), and adriamycin-resistant erythroleukemia cells (K562/adr), were all exposed to low-energy/low-dose medical diagnostic X-rays that operated at 50, 70, and 100 kV, and 100 mAs for obtaining radiation doses at 0.03, 0.07, and 0.10 mGy, respectively. Accumulation of acridine orange in the lysosomes of each cell line was determined using flow cytometry completed at 4 and 6 hours-post irradiation. Results: The data showed an increase in fluorescence intensity of acridine orange in three irradiated cells line at 4 hours post-irradiation, but this intensity did not change at 6 hours post-irradiation when compared to that of corresponding non-irradiated cells. Conclusion: This finding suggests that changes in lysosomes might be a response to low-energy/low-dose medical diagnostic X-rays. 2020-04-02T15:12:44Z 2020-04-02T15:12:44Z 2019-09-09 Journal 20760299 22234721 2-s2.0-85073443621 10.3329/bjms.v18i4.42915 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85073443621&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/67970 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
topic |
Medicine |
spellingShingle |
Medicine Montree Tungjai Nuttakan Tubthaing Suchart Kothan Lysosomes of cancerous and normal cells in response to low-energy/low-dose medical diagnostic X-rays |
description |
© 2019, Ibn Sina Trust. All rights reserved. Background: Low-energy/low-dose ionizing radiation is increasingly being used in medical diagnosis, yet the effects of low-energy/low-dose medical diagnostic X-rays on biological systems remains a mystery. Thus, the aim of this present study is to determine the characteristics of lysosomes of cancerous and normal cells in response to low-energy/low-dose medical diagnostic X-rays. Methods and materials: Three cell lines composed of peripheral blood mononuclear cells (PBMCs), adriamycin-sensitive erythroleukemia cells (K562), and adriamycin-resistant erythroleukemia cells (K562/adr), were all exposed to low-energy/low-dose medical diagnostic X-rays that operated at 50, 70, and 100 kV, and 100 mAs for obtaining radiation doses at 0.03, 0.07, and 0.10 mGy, respectively. Accumulation of acridine orange in the lysosomes of each cell line was determined using flow cytometry completed at 4 and 6 hours-post irradiation. Results: The data showed an increase in fluorescence intensity of acridine orange in three irradiated cells line at 4 hours post-irradiation, but this intensity did not change at 6 hours post-irradiation when compared to that of corresponding non-irradiated cells. Conclusion: This finding suggests that changes in lysosomes might be a response to low-energy/low-dose medical diagnostic X-rays. |
format |
Journal |
author |
Montree Tungjai Nuttakan Tubthaing Suchart Kothan |
author_facet |
Montree Tungjai Nuttakan Tubthaing Suchart Kothan |
author_sort |
Montree Tungjai |
title |
Lysosomes of cancerous and normal cells in response to low-energy/low-dose medical diagnostic X-rays |
title_short |
Lysosomes of cancerous and normal cells in response to low-energy/low-dose medical diagnostic X-rays |
title_full |
Lysosomes of cancerous and normal cells in response to low-energy/low-dose medical diagnostic X-rays |
title_fullStr |
Lysosomes of cancerous and normal cells in response to low-energy/low-dose medical diagnostic X-rays |
title_full_unstemmed |
Lysosomes of cancerous and normal cells in response to low-energy/low-dose medical diagnostic X-rays |
title_sort |
lysosomes of cancerous and normal cells in response to low-energy/low-dose medical diagnostic x-rays |
publishDate |
2020 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85073443621&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/67970 |
_version_ |
1681426733755006976 |