Simplified model of cooling/heating load prediction for various air-conditioned room types

© 2019 The purpose of this study is to develop simplified cooling/heating load models for a various air-conditioned room, applying the Buckingham-Pi theorem. The model is used to estimate cooling/heating loads of air-conditioned room at reduced calculation time. An experimental room for cooling load...

Full description

Saved in:
Bibliographic Details
Main Authors: Napassawan Khammayom, Naoki Maruyama, Chatchawan Chaichana
Format: Journal
Published: 2020
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85081163728&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/68380
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-68380
record_format dspace
spelling th-cmuir.6653943832-683802020-04-02T15:25:44Z Simplified model of cooling/heating load prediction for various air-conditioned room types Napassawan Khammayom Naoki Maruyama Chatchawan Chaichana Energy © 2019 The purpose of this study is to develop simplified cooling/heating load models for a various air-conditioned room, applying the Buckingham-Pi theorem. The model is used to estimate cooling/heating loads of air-conditioned room at reduced calculation time. An experimental room for cooling load had been set up at Chiang Mai University, Thailand in summer season during March to April in 2018. On the other hand, an experiment room for heating load had been set up at Mie University, Japan during December 2018 to February 2019. Room temperatures were set at 27 °C–25 °C for cooling and 24 °C–21 °C for heating. Collected data, such as room air temperature, room relative humidity, ambient temperature and solar radiation were used to calculate appropriate constants for cooling/heating load model. To validate the accuracy of the simplified model, calculated heating/cooling load from the model was compared to the calculated cooling/heating load from the traditional method. The results demonstrated that the simplified model developed from Buckingham-Pi theorem could estimate the cooling/heating load by low computational complexity with acceptable accuracy, comparing to results from traditional calculation method. 2020-04-02T15:25:44Z 2020-04-02T15:25:44Z 2020-02-01 Journal 23524847 2-s2.0-85081163728 10.1016/j.egyr.2019.11.086 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85081163728&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/68380
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Energy
spellingShingle Energy
Napassawan Khammayom
Naoki Maruyama
Chatchawan Chaichana
Simplified model of cooling/heating load prediction for various air-conditioned room types
description © 2019 The purpose of this study is to develop simplified cooling/heating load models for a various air-conditioned room, applying the Buckingham-Pi theorem. The model is used to estimate cooling/heating loads of air-conditioned room at reduced calculation time. An experimental room for cooling load had been set up at Chiang Mai University, Thailand in summer season during March to April in 2018. On the other hand, an experiment room for heating load had been set up at Mie University, Japan during December 2018 to February 2019. Room temperatures were set at 27 °C–25 °C for cooling and 24 °C–21 °C for heating. Collected data, such as room air temperature, room relative humidity, ambient temperature and solar radiation were used to calculate appropriate constants for cooling/heating load model. To validate the accuracy of the simplified model, calculated heating/cooling load from the model was compared to the calculated cooling/heating load from the traditional method. The results demonstrated that the simplified model developed from Buckingham-Pi theorem could estimate the cooling/heating load by low computational complexity with acceptable accuracy, comparing to results from traditional calculation method.
format Journal
author Napassawan Khammayom
Naoki Maruyama
Chatchawan Chaichana
author_facet Napassawan Khammayom
Naoki Maruyama
Chatchawan Chaichana
author_sort Napassawan Khammayom
title Simplified model of cooling/heating load prediction for various air-conditioned room types
title_short Simplified model of cooling/heating load prediction for various air-conditioned room types
title_full Simplified model of cooling/heating load prediction for various air-conditioned room types
title_fullStr Simplified model of cooling/heating load prediction for various air-conditioned room types
title_full_unstemmed Simplified model of cooling/heating load prediction for various air-conditioned room types
title_sort simplified model of cooling/heating load prediction for various air-conditioned room types
publishDate 2020
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85081163728&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/68380
_version_ 1681426809650937856