Development of Anti-Islanding Hybrid Detection Technique in Grid-Connected Distributed Generation
This thesis is development of anti-islanding hybrid detection technique in grid-connected distributed generation. The approach in research and development are as follows. All islanding detection techniques and relevant content are compiled & summarized. The weaknesses of over/under-voltage islan...
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Theses and Dissertations |
Language: | English |
Published: |
เชียงใหม่ : บัณฑิตวิทยาลัย มหาวิทยาลัยเชียงใหม่
2020
|
Online Access: | http://cmuir.cmu.ac.th/jspui/handle/6653943832/69345 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
Language: | English |
id |
th-cmuir.6653943832-69345 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-693452020-08-06T01:43:24Z Development of Anti-Islanding Hybrid Detection Technique in Grid-Connected Distributed Generation การพัฒนาวิธีการตรวจจับแบบไฮบริดสำหรับการป้องกันการเกิดการจ่ายไฟแบบแยกตัวอิสระในระบบจำหน่ายไฟฟ้าที่เชื่อมต่อหน่วยผลิตไฟฟ้าแบบกระจายตัว Manop Yingram Assoc. Prof. Dr. Suttichai Premrudeepreechacharn Asst. Prof. Dr. Yuttana Kumsuwan Dr. Peerapol Jirapong This thesis is development of anti-islanding hybrid detection technique in grid-connected distributed generation. The approach in research and development are as follows. All islanding detection techniques and relevant content are compiled & summarized. The weaknesses of over/under-voltage islanding detection technique by Powerworld Simulator Program is suggested. The phenomenon of voltage at point of common coupling, after the islanding condition happened is demonstrated on experiments with inverter 1 phase 1 kW. The new hybrid technique that is an over/under-voltage and under voltage shift technique is proposed. The new hybrid technique has demonstrated on Matlab/Simulink. The simulation results lead to conclusions that the over/under-voltage and under voltage shift of hybrid islanding detection method is very effective because it can determine anti-islanding condition very fast. ∆P/P > 38.41% could determine anti-islanding condition within 0.04 s; ∆P/P < -24.39% could determine anti-islanding condition within 0.04 s; -24.39% ≤ ∆P/P ≤ 38.41% could determine anti-islanding condition within 0.08 s. This method perturbed the system, only in the case of -24.39% ≤ ∆P/P ≤ 38.41% which the control system of inverter injected a signal of under voltage shift as necessary to check if the occurrence condition was an islanding condition. 2020-08-06T01:43:24Z 2020-08-06T01:43:24Z 2014-11 Thesis http://cmuir.cmu.ac.th/jspui/handle/6653943832/69345 en เชียงใหม่ : บัณฑิตวิทยาลัย มหาวิทยาลัยเชียงใหม่ |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
continent |
Asia |
country |
Thailand Thailand |
content_provider |
Chiang Mai University Library |
collection |
CMU Intellectual Repository |
language |
English |
description |
This thesis is development of anti-islanding hybrid detection technique in grid-connected distributed generation. The approach in research and development are as follows. All islanding detection techniques and relevant content are compiled & summarized. The weaknesses of over/under-voltage islanding detection technique by Powerworld Simulator Program is suggested. The phenomenon of voltage at point of common coupling, after the islanding condition happened is demonstrated on experiments with inverter 1 phase 1 kW. The new hybrid technique that is an over/under-voltage and under voltage shift technique is proposed.
The new hybrid technique has demonstrated on Matlab/Simulink. The simulation results lead to conclusions that the over/under-voltage and under voltage shift of hybrid islanding detection method is very effective because it can determine anti-islanding condition very fast. ∆P/P > 38.41% could determine anti-islanding condition within 0.04 s; ∆P/P < -24.39% could determine anti-islanding condition within 0.04 s; -24.39% ≤ ∆P/P ≤ 38.41% could determine anti-islanding condition within 0.08 s. This method perturbed the system, only in the case of -24.39% ≤ ∆P/P ≤ 38.41% which the control system of inverter injected a signal of under voltage shift as necessary to check if the occurrence condition was an islanding condition. |
author2 |
Assoc. Prof. Dr. Suttichai Premrudeepreechacharn |
author_facet |
Assoc. Prof. Dr. Suttichai Premrudeepreechacharn Manop Yingram |
format |
Theses and Dissertations |
author |
Manop Yingram |
spellingShingle |
Manop Yingram Development of Anti-Islanding Hybrid Detection Technique in Grid-Connected Distributed Generation |
author_sort |
Manop Yingram |
title |
Development of Anti-Islanding Hybrid Detection Technique in Grid-Connected Distributed Generation |
title_short |
Development of Anti-Islanding Hybrid Detection Technique in Grid-Connected Distributed Generation |
title_full |
Development of Anti-Islanding Hybrid Detection Technique in Grid-Connected Distributed Generation |
title_fullStr |
Development of Anti-Islanding Hybrid Detection Technique in Grid-Connected Distributed Generation |
title_full_unstemmed |
Development of Anti-Islanding Hybrid Detection Technique in Grid-Connected Distributed Generation |
title_sort |
development of anti-islanding hybrid detection technique in grid-connected distributed generation |
publisher |
เชียงใหม่ : บัณฑิตวิทยาลัย มหาวิทยาลัยเชียงใหม่ |
publishDate |
2020 |
url |
http://cmuir.cmu.ac.th/jspui/handle/6653943832/69345 |
_version_ |
1681752640780763136 |