Development of Anti-Islanding Hybrid Detection Technique in Grid-Connected Distributed Generation

This thesis is development of anti-islanding hybrid detection technique in grid-connected distributed generation. The approach in research and development are as follows. All islanding detection techniques and relevant content are compiled & summarized. The weaknesses of over/under-voltage islan...

Full description

Saved in:
Bibliographic Details
Main Author: Manop Yingram
Other Authors: Assoc. Prof. Dr. Suttichai Premrudeepreechacharn
Format: Theses and Dissertations
Language:English
Published: เชียงใหม่ : บัณฑิตวิทยาลัย มหาวิทยาลัยเชียงใหม่ 2020
Online Access:http://cmuir.cmu.ac.th/jspui/handle/6653943832/69345
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
Language: English
id th-cmuir.6653943832-69345
record_format dspace
spelling th-cmuir.6653943832-693452020-08-06T01:43:24Z Development of Anti-Islanding Hybrid Detection Technique in Grid-Connected Distributed Generation การพัฒนาวิธีการตรวจจับแบบไฮบริดสำหรับการป้องกันการเกิดการจ่ายไฟแบบแยกตัวอิสระในระบบจำหน่ายไฟฟ้าที่เชื่อมต่อหน่วยผลิตไฟฟ้าแบบกระจายตัว Manop Yingram Assoc. Prof. Dr. Suttichai Premrudeepreechacharn Asst. Prof. Dr. Yuttana Kumsuwan Dr. Peerapol Jirapong This thesis is development of anti-islanding hybrid detection technique in grid-connected distributed generation. The approach in research and development are as follows. All islanding detection techniques and relevant content are compiled & summarized. The weaknesses of over/under-voltage islanding detection technique by Powerworld Simulator Program is suggested. The phenomenon of voltage at point of common coupling, after the islanding condition happened is demonstrated on experiments with inverter 1 phase 1 kW. The new hybrid technique that is an over/under-voltage and under voltage shift technique is proposed. The new hybrid technique has demonstrated on Matlab/Simulink. The simulation results lead to conclusions that the over/under-voltage and under voltage shift of hybrid islanding detection method is very effective because it can determine anti-islanding condition very fast. ∆P/P > 38.41% could determine anti-islanding condition within 0.04 s; ∆P/P < -24.39% could determine anti-islanding condition within 0.04 s; -24.39% ≤ ∆P/P ≤ 38.41% could determine anti-islanding condition within 0.08 s. This method perturbed the system, only in the case of -24.39% ≤ ∆P/P ≤ 38.41% which the control system of inverter injected a signal of under voltage shift as necessary to check if the occurrence condition was an islanding condition. 2020-08-06T01:43:24Z 2020-08-06T01:43:24Z 2014-11 Thesis http://cmuir.cmu.ac.th/jspui/handle/6653943832/69345 en เชียงใหม่ : บัณฑิตวิทยาลัย มหาวิทยาลัยเชียงใหม่
institution Chiang Mai University
building Chiang Mai University Library
continent Asia
country Thailand
Thailand
content_provider Chiang Mai University Library
collection CMU Intellectual Repository
language English
description This thesis is development of anti-islanding hybrid detection technique in grid-connected distributed generation. The approach in research and development are as follows. All islanding detection techniques and relevant content are compiled & summarized. The weaknesses of over/under-voltage islanding detection technique by Powerworld Simulator Program is suggested. The phenomenon of voltage at point of common coupling, after the islanding condition happened is demonstrated on experiments with inverter 1 phase 1 kW. The new hybrid technique that is an over/under-voltage and under voltage shift technique is proposed. The new hybrid technique has demonstrated on Matlab/Simulink. The simulation results lead to conclusions that the over/under-voltage and under voltage shift of hybrid islanding detection method is very effective because it can determine anti-islanding condition very fast. ∆P/P > 38.41% could determine anti-islanding condition within 0.04 s; ∆P/P < -24.39% could determine anti-islanding condition within 0.04 s; -24.39% ≤ ∆P/P ≤ 38.41% could determine anti-islanding condition within 0.08 s. This method perturbed the system, only in the case of -24.39% ≤ ∆P/P ≤ 38.41% which the control system of inverter injected a signal of under voltage shift as necessary to check if the occurrence condition was an islanding condition.
author2 Assoc. Prof. Dr. Suttichai Premrudeepreechacharn
author_facet Assoc. Prof. Dr. Suttichai Premrudeepreechacharn
Manop Yingram
format Theses and Dissertations
author Manop Yingram
spellingShingle Manop Yingram
Development of Anti-Islanding Hybrid Detection Technique in Grid-Connected Distributed Generation
author_sort Manop Yingram
title Development of Anti-Islanding Hybrid Detection Technique in Grid-Connected Distributed Generation
title_short Development of Anti-Islanding Hybrid Detection Technique in Grid-Connected Distributed Generation
title_full Development of Anti-Islanding Hybrid Detection Technique in Grid-Connected Distributed Generation
title_fullStr Development of Anti-Islanding Hybrid Detection Technique in Grid-Connected Distributed Generation
title_full_unstemmed Development of Anti-Islanding Hybrid Detection Technique in Grid-Connected Distributed Generation
title_sort development of anti-islanding hybrid detection technique in grid-connected distributed generation
publisher เชียงใหม่ : บัณฑิตวิทยาลัย มหาวิทยาลัยเชียงใหม่
publishDate 2020
url http://cmuir.cmu.ac.th/jspui/handle/6653943832/69345
_version_ 1681752640780763136