การสร้างเครื่องวัดสนามแม่เหล็กเชิงอะตอมเพื่อการประยุกต์ ในทางชีวการแพทย์
Atomic magnetometer has been developed to have high sensitivity of 12 10 / z T H − or better, which is in the range of the magnetic signals from human organs, such as heart and brain. The ultimate goal of this project is to construct an atomic magnetometer based on rubidium vapour cell with sensi...
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Theses and Dissertations |
Language: | other |
Published: |
เชียงใหม่ : บัณฑิตวิทยาลัย มหาวิทยาลัยเชียงใหม่
2020
|
Online Access: | http://cmuir.cmu.ac.th/jspui/handle/6653943832/69462 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
Language: | other |
id |
th-cmuir.6653943832-69462 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-694622020-08-10T01:33:52Z การสร้างเครื่องวัดสนามแม่เหล็กเชิงอะตอมเพื่อการประยุกต์ ในทางชีวการแพทย์ Construction of Atomic Magnetometer for Biomedical Applications กิตติพงศ์ ปันธินวน ผู้ช่วยศาสตราจารย์ ดร.สุเมธ สกุลเสริมสุข Atomic magnetometer has been developed to have high sensitivity of 12 10 / z T H − or better, which is in the range of the magnetic signals from human organs, such as heart and brain. The ultimate goal of this project is to construct an atomic magnetometer based on rubidium vapour cell with sensitivity of 10 12T / Hz − . For this kind of magnetometer, the optical pumping of rubidium vapour is an important process for measuring magnetic fields. Therefore, we designed and constructed essential parts of the atomic magnetometer, including light source, Helmholtz coils, temperature controller and photodetector for optical pumping experiment. Each part was tested, and the results of its measured characteristics were showed and discussed. From our experiment set up, we attempted to determine the density of rubidium vapour as a function of temperature by measuring the intensity of linearly polarized light via rubidium vapour cell. The results showed the intensities of the transmitted laser decreased abruptly at 318K when the temperature increased by 2 K from room temperature to 323K, and increased at 314K when the temperature decreased from 323K to room temperature during naturally cooling down. We suggested that the suddenly changes of laser intensity strongly correlate with the melting point of rubidium at 312.45K. We believe that the progress achieved here pave the way to the success in the construction of atomic magnetometer. 2020-08-10T01:33:52Z 2020-08-10T01:33:52Z 2020-04 Thesis http://cmuir.cmu.ac.th/jspui/handle/6653943832/69462 other เชียงใหม่ : บัณฑิตวิทยาลัย มหาวิทยาลัยเชียงใหม่ |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
continent |
Asia |
country |
Thailand Thailand |
content_provider |
Chiang Mai University Library |
collection |
CMU Intellectual Repository |
language |
other |
description |
Atomic magnetometer has been developed to have high sensitivity of 12 10 / z T H − or better,
which is in the range of the magnetic signals from human organs, such as heart and brain. The ultimate
goal of this project is to construct an atomic magnetometer based on rubidium vapour cell with
sensitivity of 10 12T / Hz − . For this kind of magnetometer, the optical pumping of rubidium vapour
is an important process for measuring magnetic fields. Therefore, we designed and constructed
essential parts of the atomic magnetometer, including light source, Helmholtz coils, temperature
controller and photodetector for optical pumping experiment. Each part was tested, and the results of
its measured characteristics were showed and discussed. From our experiment set up, we attempted
to determine the density of rubidium vapour as a function of temperature by measuring the intensity
of linearly polarized light via rubidium vapour cell. The results showed the intensities of the
transmitted laser decreased abruptly at 318K when the temperature increased by 2 K from room
temperature to 323K, and increased at 314K when the temperature decreased from 323K to
room temperature during naturally cooling down. We suggested that the suddenly changes of laser
intensity strongly correlate with the melting point of rubidium at 312.45K. We believe that the
progress achieved here pave the way to the success in the construction of atomic magnetometer. |
author2 |
ผู้ช่วยศาสตราจารย์ ดร.สุเมธ สกุลเสริมสุข |
author_facet |
ผู้ช่วยศาสตราจารย์ ดร.สุเมธ สกุลเสริมสุข กิตติพงศ์ ปันธินวน |
format |
Theses and Dissertations |
author |
กิตติพงศ์ ปันธินวน |
spellingShingle |
กิตติพงศ์ ปันธินวน การสร้างเครื่องวัดสนามแม่เหล็กเชิงอะตอมเพื่อการประยุกต์ ในทางชีวการแพทย์ |
author_sort |
กิตติพงศ์ ปันธินวน |
title |
การสร้างเครื่องวัดสนามแม่เหล็กเชิงอะตอมเพื่อการประยุกต์ ในทางชีวการแพทย์ |
title_short |
การสร้างเครื่องวัดสนามแม่เหล็กเชิงอะตอมเพื่อการประยุกต์ ในทางชีวการแพทย์ |
title_full |
การสร้างเครื่องวัดสนามแม่เหล็กเชิงอะตอมเพื่อการประยุกต์ ในทางชีวการแพทย์ |
title_fullStr |
การสร้างเครื่องวัดสนามแม่เหล็กเชิงอะตอมเพื่อการประยุกต์ ในทางชีวการแพทย์ |
title_full_unstemmed |
การสร้างเครื่องวัดสนามแม่เหล็กเชิงอะตอมเพื่อการประยุกต์ ในทางชีวการแพทย์ |
title_sort |
การสร้างเครื่องวัดสนามแม่เหล็กเชิงอะตอมเพื่อการประยุกต์ ในทางชีวการแพทย์ |
publisher |
เชียงใหม่ : บัณฑิตวิทยาลัย มหาวิทยาลัยเชียงใหม่ |
publishDate |
2020 |
url |
http://cmuir.cmu.ac.th/jspui/handle/6653943832/69462 |
_version_ |
1681752708356243456 |