Retraction Hooks of Different Lengths for Maxillary Whole Arch Distalization with Miniscrew Anchorage : A Finite Element Analysis

Objectives: To evaluate the von Mises stress distribution in the periodontal ligament and the displacement pattern of maxillary whole arch distalization applied to retraction hooks of different lengths with miniscrew anchorage and to determine the optimal length of retraction hook, using the finite...

Full description

Saved in:
Bibliographic Details
Main Author: Vanichaya Tangsumroengvong
Other Authors: Clin. Prof. Virush Patanaporn
Format: Theses and Dissertations
Language:English
Published: เชียงใหม่ : บัณฑิตวิทยาลัย มหาวิทยาลัยเชียงใหม่ 2020
Subjects:
Online Access:http://cmuir.cmu.ac.th/jspui/handle/6653943832/69464
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
Language: English
id th-cmuir.6653943832-69464
record_format dspace
spelling th-cmuir.6653943832-694642020-08-10T01:34:09Z Retraction Hooks of Different Lengths for Maxillary Whole Arch Distalization with Miniscrew Anchorage : A Finite Element Analysis การใช้ตะขอดึงรั้งที่มีความยาวแตกต่างกันในการเคลื่อนฟันทุกซี่ในขากรรไกรบนไปทางด้านไกลกลางโดยใช้หลักยึดหมุดฝังในกระดูก:วิเคราะห์ด้วยวิธีไฟไนเอลิเมนต์ Vanichaya Tangsumroengvong Clin. Prof. Virush Patanaporn Asst. Prof. Dr. Chaiy Rungsiyakul Whole arch distalization En masse distalization finite element retraction hook Objectives: To evaluate the von Mises stress distribution in the periodontal ligament and the displacement pattern of maxillary whole arch distalization applied to retraction hooks of different lengths with miniscrew anchorage and to determine the optimal length of retraction hook, using the finite element method. Methods: A finite element model of maxillary teeth with periodontal ligament and alveolar bone was constructed. The miniscrews were placed bilaterally 6 mm above the buccal cemento-enamel junction at the modified infrazygomatic crest site. The distalization force of 200g was applied to 0-, 2-, 4-, 6-, 8-mm length retraction hooks located between the lateral incisor and canine. The stress distribution in the periodontal ligament and the displacement of the teeth were analyzed. The optimal length of retraction hook for maximal distal movement of the maxillary whole arch along the occlusal plane was investigated. Results: The von Mises stress in the anterior teeth was greater than in the posterior teeth with all hook lengths. With the 0-mm and 2-mm lengths, the anterior teeth were extruded and tipped palatally; the posterior teeth were intruded and tipped distally. With the 4-mm length, all maxillary teeth were distalized along the occlusal plane with minimal movement in the vertical direction. The anterior teeth were slightly tipped labially; the posterior teeth were slightly tipped distally. With the 6-mm and 8-mm lengths, the anterior teeth were intruded and tipped labially; the posterior teeth were extruded and tipped distally. The optimal length in this study was found to be 4 mm. Conclusions: Different lengths of retraction hook resulted in different patterns of stress distribution in the PDL and in different patterns of displacement of the maxillary teeth in whole arch distalization. The optimal length of retraction hook was 4 mm for maximal distal movement of the maxillary whole arch along the occlusal plane. 2020-08-10T01:34:09Z 2020-08-10T01:34:09Z 2020-03 Thesis http://cmuir.cmu.ac.th/jspui/handle/6653943832/69464 en เชียงใหม่ : บัณฑิตวิทยาลัย มหาวิทยาลัยเชียงใหม่
institution Chiang Mai University
building Chiang Mai University Library
continent Asia
country Thailand
Thailand
content_provider Chiang Mai University Library
collection CMU Intellectual Repository
language English
topic Whole arch distalization
En masse distalization
finite element
retraction hook
spellingShingle Whole arch distalization
En masse distalization
finite element
retraction hook
Vanichaya Tangsumroengvong
Retraction Hooks of Different Lengths for Maxillary Whole Arch Distalization with Miniscrew Anchorage : A Finite Element Analysis
description Objectives: To evaluate the von Mises stress distribution in the periodontal ligament and the displacement pattern of maxillary whole arch distalization applied to retraction hooks of different lengths with miniscrew anchorage and to determine the optimal length of retraction hook, using the finite element method. Methods: A finite element model of maxillary teeth with periodontal ligament and alveolar bone was constructed. The miniscrews were placed bilaterally 6 mm above the buccal cemento-enamel junction at the modified infrazygomatic crest site. The distalization force of 200g was applied to 0-, 2-, 4-, 6-, 8-mm length retraction hooks located between the lateral incisor and canine. The stress distribution in the periodontal ligament and the displacement of the teeth were analyzed. The optimal length of retraction hook for maximal distal movement of the maxillary whole arch along the occlusal plane was investigated. Results: The von Mises stress in the anterior teeth was greater than in the posterior teeth with all hook lengths. With the 0-mm and 2-mm lengths, the anterior teeth were extruded and tipped palatally; the posterior teeth were intruded and tipped distally. With the 4-mm length, all maxillary teeth were distalized along the occlusal plane with minimal movement in the vertical direction. The anterior teeth were slightly tipped labially; the posterior teeth were slightly tipped distally. With the 6-mm and 8-mm lengths, the anterior teeth were intruded and tipped labially; the posterior teeth were extruded and tipped distally. The optimal length in this study was found to be 4 mm. Conclusions: Different lengths of retraction hook resulted in different patterns of stress distribution in the PDL and in different patterns of displacement of the maxillary teeth in whole arch distalization. The optimal length of retraction hook was 4 mm for maximal distal movement of the maxillary whole arch along the occlusal plane.
author2 Clin. Prof. Virush Patanaporn
author_facet Clin. Prof. Virush Patanaporn
Vanichaya Tangsumroengvong
format Theses and Dissertations
author Vanichaya Tangsumroengvong
author_sort Vanichaya Tangsumroengvong
title Retraction Hooks of Different Lengths for Maxillary Whole Arch Distalization with Miniscrew Anchorage : A Finite Element Analysis
title_short Retraction Hooks of Different Lengths for Maxillary Whole Arch Distalization with Miniscrew Anchorage : A Finite Element Analysis
title_full Retraction Hooks of Different Lengths for Maxillary Whole Arch Distalization with Miniscrew Anchorage : A Finite Element Analysis
title_fullStr Retraction Hooks of Different Lengths for Maxillary Whole Arch Distalization with Miniscrew Anchorage : A Finite Element Analysis
title_full_unstemmed Retraction Hooks of Different Lengths for Maxillary Whole Arch Distalization with Miniscrew Anchorage : A Finite Element Analysis
title_sort retraction hooks of different lengths for maxillary whole arch distalization with miniscrew anchorage : a finite element analysis
publisher เชียงใหม่ : บัณฑิตวิทยาลัย มหาวิทยาลัยเชียงใหม่
publishDate 2020
url http://cmuir.cmu.ac.th/jspui/handle/6653943832/69464
_version_ 1681752710922108928