Computerised occlusal analysis of mini-dental implant-retained mandibular overdentures: A 1-year prospective clinical study

© 2020 John Wiley & Sons Ltd Occlusal analysis is a substantial tool for the functional improvement evaluation after using implant-retained overdenture comparing to complete denture without dental implant retaining. To evaluate occlusal pattern, chewing force distribution in mini-dental implan...

Full description

Saved in:
Bibliographic Details
Main Authors: Phongkamon Kabbua, Weerapan Aunmeungtong, Pathawee Khongkhunthian
Format: Journal
Published: 2020
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85085489510&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/70473
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-70473
record_format dspace
spelling th-cmuir.6653943832-704732020-10-14T08:31:39Z Computerised occlusal analysis of mini-dental implant-retained mandibular overdentures: A 1-year prospective clinical study Phongkamon Kabbua Weerapan Aunmeungtong Pathawee Khongkhunthian Dentistry © 2020 John Wiley & Sons Ltd Occlusal analysis is a substantial tool for the functional improvement evaluation after using implant-retained overdenture comparing to complete denture without dental implant retaining. To evaluate occlusal pattern, chewing force distribution in mini-dental implant-retained mandibular overdentures by computerised occlusal analysis system and to compare patient satisfaction after 1-year function. Thirty-one patients wearing complete dentures were included in the study. Prior to mini-dental implant-retained treatment, all patients were assessed for occlusion and force distribution using computerised occlusal analysis system (T-Scan®), and then, all patients received two mini-dental implant-retained mandibular overdentures. Mini-dental implants were immediately loaded using low vertical profile attachments (Equator®). T-Scan® was used to evaluate chewing force and force distribution at 1 day, 3 months, 6 months and 12 months. The patient satisfactions before implant placement and after 1 year were evaluated using questionnaires which included satisfaction of denture quality, psychosocial behaviour and chewing efficiency modified from the validated questionnaires. Clinical evaluation of two mini-dental implant-retained mandibular overdentures showed 100% success rate after 1 year. T-Scan® demonstrated that maximum occlusal contact force increased continuously. The force distribution; the tooth contact number increased over the period. At 1-year follow-up, overall patient satisfaction was significantly greater than before receiving mini-dental implant treatment (P <.001). Using computerised occlusal analysis, mini-dental implants improve complete denture function significantly in terms of maximum occlusal contact force, tooth contact number without the impairment of force distribution. The oral function of the patients has been enhanced. 2020-10-14T08:31:39Z 2020-10-14T08:31:39Z 2020-06-01 Journal 13652842 0305182X 2-s2.0-85085489510 10.1111/joor.12969 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85085489510&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/70473
institution Chiang Mai University
building Chiang Mai University Library
continent Asia
country Thailand
Thailand
content_provider Chiang Mai University Library
collection CMU Intellectual Repository
topic Dentistry
spellingShingle Dentistry
Phongkamon Kabbua
Weerapan Aunmeungtong
Pathawee Khongkhunthian
Computerised occlusal analysis of mini-dental implant-retained mandibular overdentures: A 1-year prospective clinical study
description © 2020 John Wiley & Sons Ltd Occlusal analysis is a substantial tool for the functional improvement evaluation after using implant-retained overdenture comparing to complete denture without dental implant retaining. To evaluate occlusal pattern, chewing force distribution in mini-dental implant-retained mandibular overdentures by computerised occlusal analysis system and to compare patient satisfaction after 1-year function. Thirty-one patients wearing complete dentures were included in the study. Prior to mini-dental implant-retained treatment, all patients were assessed for occlusion and force distribution using computerised occlusal analysis system (T-Scan®), and then, all patients received two mini-dental implant-retained mandibular overdentures. Mini-dental implants were immediately loaded using low vertical profile attachments (Equator®). T-Scan® was used to evaluate chewing force and force distribution at 1 day, 3 months, 6 months and 12 months. The patient satisfactions before implant placement and after 1 year were evaluated using questionnaires which included satisfaction of denture quality, psychosocial behaviour and chewing efficiency modified from the validated questionnaires. Clinical evaluation of two mini-dental implant-retained mandibular overdentures showed 100% success rate after 1 year. T-Scan® demonstrated that maximum occlusal contact force increased continuously. The force distribution; the tooth contact number increased over the period. At 1-year follow-up, overall patient satisfaction was significantly greater than before receiving mini-dental implant treatment (P <.001). Using computerised occlusal analysis, mini-dental implants improve complete denture function significantly in terms of maximum occlusal contact force, tooth contact number without the impairment of force distribution. The oral function of the patients has been enhanced.
format Journal
author Phongkamon Kabbua
Weerapan Aunmeungtong
Pathawee Khongkhunthian
author_facet Phongkamon Kabbua
Weerapan Aunmeungtong
Pathawee Khongkhunthian
author_sort Phongkamon Kabbua
title Computerised occlusal analysis of mini-dental implant-retained mandibular overdentures: A 1-year prospective clinical study
title_short Computerised occlusal analysis of mini-dental implant-retained mandibular overdentures: A 1-year prospective clinical study
title_full Computerised occlusal analysis of mini-dental implant-retained mandibular overdentures: A 1-year prospective clinical study
title_fullStr Computerised occlusal analysis of mini-dental implant-retained mandibular overdentures: A 1-year prospective clinical study
title_full_unstemmed Computerised occlusal analysis of mini-dental implant-retained mandibular overdentures: A 1-year prospective clinical study
title_sort computerised occlusal analysis of mini-dental implant-retained mandibular overdentures: a 1-year prospective clinical study
publishDate 2020
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85085489510&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/70473
_version_ 1681752909082001408