© 2020 Petpiroon et al. This work is published and licensed by Dove Medical Press Limited. Importance: To compare treatment outcomes among a stent group, ligature group and combined groupineyeswithrefractoryglaucoma. Background: Various techniques have been used intra-operatively to restrict the aqu...

Full description

Saved in:
Bibliographic Details
Main Authors: Purit Petpiroon, Thanyathorn Vijittrakarnrung, Wasu Supakontanasan, Apichat Tantraworasin, Yanin Suwan
Format: Journal
Published: 2020
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85086653407&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/70950
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-70950
record_format dspace
spelling th-cmuir.6653943832-709502020-10-14T08:45:26Z Comparison of two tube-modification techniques in baerveldt glaucoma implantation in refractory glaucoma Purit Petpiroon Thanyathorn Vijittrakarnrung Wasu Supakontanasan Apichat Tantraworasin Yanin Suwan Medicine © 2020 Petpiroon et al. This work is published and licensed by Dove Medical Press Limited. Importance: To compare treatment outcomes among a stent group, ligature group and combined groupineyeswithrefractoryglaucoma. Background: Various techniques have been used intra-operatively to restrict the aqueous flow in Baerveldt glaucoma implantation. Design: Retrospective chart review. Participants: All glaucoma patients aged over 18-years old who had Baerveldt implantation in Ramathibodi Hospital, Bangkok, Thailand, between October 2011 and February 2018 were included for analysis. Methods: Retrospective interventional research was conducted. All glaucoma patients who underwent drainage device implantations were retrospectively reviewed from medical records and divided into three groups: stent group, ligature group, and combined group. The primary outcome was post-operative intraocular pressure (IOP) changes and BCVA (logMAR) change. The secondary outcome is treatment failure. Repeated measurements with mixed models and multi-level parametric survival model stratified by propensity score and eye side were used to compare the primary and secondary outcomes between stent group and ligature group. Main Outcome Measures: Treatment failure between two groups. Results: A total of 163 patients with a mean age of 57.11 ± 19.04 years, implanted with Baerveldt tube, were eligible. There were no significant differences between stent and ligature groups in terms of post-operative IOP changes [mean difference with 95% confidence interval = 0.53 (−0.49, +1.55) vs −0.02 (−0.84, +0.81); P = 0.411] and post-operative BCVA (logMAR) change (0.02 (−0.13, +0.18) vs –0.05 (−0.18, +0.07); P = 0.465). The hazard ratio and 95% confidence interval of treatment failure in ligature group were 2.57 (0.72–9.19) compared with the stent group. Conclusion: This study suggests a trend toward a better result in the stent group compared with the ligature group. Further research with a larger sample size and randomized control trial is warranted. 2020-10-14T08:45:26Z 2020-10-14T08:45:26Z 2020-01-01 Journal 11775483 11775467 2-s2.0-85086653407 10.2147/OPTH.S246905 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85086653407&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/70950
institution Chiang Mai University
building Chiang Mai University Library
continent Asia
country Thailand
Thailand
content_provider Chiang Mai University Library
collection CMU Intellectual Repository
topic Medicine
spellingShingle Medicine
Purit Petpiroon
Thanyathorn Vijittrakarnrung
Wasu Supakontanasan
Apichat Tantraworasin
Yanin Suwan
Comparison of two tube-modification techniques in baerveldt glaucoma implantation in refractory glaucoma
description © 2020 Petpiroon et al. This work is published and licensed by Dove Medical Press Limited. Importance: To compare treatment outcomes among a stent group, ligature group and combined groupineyeswithrefractoryglaucoma. Background: Various techniques have been used intra-operatively to restrict the aqueous flow in Baerveldt glaucoma implantation. Design: Retrospective chart review. Participants: All glaucoma patients aged over 18-years old who had Baerveldt implantation in Ramathibodi Hospital, Bangkok, Thailand, between October 2011 and February 2018 were included for analysis. Methods: Retrospective interventional research was conducted. All glaucoma patients who underwent drainage device implantations were retrospectively reviewed from medical records and divided into three groups: stent group, ligature group, and combined group. The primary outcome was post-operative intraocular pressure (IOP) changes and BCVA (logMAR) change. The secondary outcome is treatment failure. Repeated measurements with mixed models and multi-level parametric survival model stratified by propensity score and eye side were used to compare the primary and secondary outcomes between stent group and ligature group. Main Outcome Measures: Treatment failure between two groups. Results: A total of 163 patients with a mean age of 57.11 ± 19.04 years, implanted with Baerveldt tube, were eligible. There were no significant differences between stent and ligature groups in terms of post-operative IOP changes [mean difference with 95% confidence interval = 0.53 (−0.49, +1.55) vs −0.02 (−0.84, +0.81); P = 0.411] and post-operative BCVA (logMAR) change (0.02 (−0.13, +0.18) vs –0.05 (−0.18, +0.07); P = 0.465). The hazard ratio and 95% confidence interval of treatment failure in ligature group were 2.57 (0.72–9.19) compared with the stent group. Conclusion: This study suggests a trend toward a better result in the stent group compared with the ligature group. Further research with a larger sample size and randomized control trial is warranted.
format Journal
author Purit Petpiroon
Thanyathorn Vijittrakarnrung
Wasu Supakontanasan
Apichat Tantraworasin
Yanin Suwan
author_facet Purit Petpiroon
Thanyathorn Vijittrakarnrung
Wasu Supakontanasan
Apichat Tantraworasin
Yanin Suwan
author_sort Purit Petpiroon
title Comparison of two tube-modification techniques in baerveldt glaucoma implantation in refractory glaucoma
title_short Comparison of two tube-modification techniques in baerveldt glaucoma implantation in refractory glaucoma
title_full Comparison of two tube-modification techniques in baerveldt glaucoma implantation in refractory glaucoma
title_fullStr Comparison of two tube-modification techniques in baerveldt glaucoma implantation in refractory glaucoma
title_full_unstemmed Comparison of two tube-modification techniques in baerveldt glaucoma implantation in refractory glaucoma
title_sort comparison of two tube-modification techniques in baerveldt glaucoma implantation in refractory glaucoma
publishDate 2020
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85086653407&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/70950
_version_ 1681752996047749120