Factors associated with failure of intermittent nebulization with short-acting beta-agonists in children with severe asthma exacerbation

© 2020 Kulalert et al. Purpose: Intermittent nebulization of short-acting beta-agonists (SABA) is the initial treatment of choice for children with asthma exacerbation. However, children with severe asthma exacerbation (SAE) may not show an adequate response and need aggressive stepwise therapy. We...

Full description

Saved in:
Bibliographic Details
Main Authors: Prapasri Kulalert, Phichayut Phinyo, Jayanton Patumanond, Chutima Smathakanee, Wantida Chuenjit, Sira Nanthapisal
Format: Journal
Published: 2020
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85090607376&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/70955
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-70955
record_format dspace
spelling th-cmuir.6653943832-709552020-10-14T08:45:29Z Factors associated with failure of intermittent nebulization with short-acting beta-agonists in children with severe asthma exacerbation Prapasri Kulalert Phichayut Phinyo Jayanton Patumanond Chutima Smathakanee Wantida Chuenjit Sira Nanthapisal Medicine © 2020 Kulalert et al. Purpose: Intermittent nebulization of short-acting beta-agonists (SABA) is the initial treatment of choice for children with asthma exacerbation. However, children with severe asthma exacerbation (SAE) may not show an adequate response and need aggressive stepwise therapy. We aimed to explore factors associated with a poor response to intermittent nebulized SABA in children with SAE. Methods: A retrospective cohort study of children with SAE diagnosed according to the definition of the British Guidelines on the Management of Asthma, who were admitted at Hat Yai Hospital from January 1, 2015, to December 31, 2017. All children were treated with intermittent SABA nebulization. Treatment failure was defined as children needing escalated therapy. Logistic regression with confounding score adjustment was used to explore the predictors of treatment failure. Results: One hundred thirty-three children were included in the analysis, 59 were in the failure group and 74 were in the success group. After adjusting for potential confounders, they were significantly associated with a previous history of intubation (adjusted OR 6.46, 95% CI 1.13 to 36.79, p=0.036), receiving <3 doses of nebulized salbutamol in the emergency room (ER, aOR 3.21, 95% CI 1.15 to 9.02, p=0.027), ER measured oxygen saturation (SpO2) <92% (adjusted OR 3.02, 95% CI 1.18 to 7.75, p=0.022), and exacerbation triggered by pneumonia (adjusted OR 2.67, 95% CI 1.19 to 6.00, p=0.017). Conclusion: We identified four prognostic factors of treatment failure in children with SAE: a previous history of intubation; receiving <3 doses of nebulized salbutamol in the ER, SpO2 at ER <92%; and exacerbation triggered by pneumonia. Further prospective studies are required to confirm our findings before clinical implementation. 2020-10-14T08:45:29Z 2020-10-14T08:45:29Z 2020-01-01 Journal 11786965 2-s2.0-85090607376 10.2147/JAA.S258549 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85090607376&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/70955
institution Chiang Mai University
building Chiang Mai University Library
continent Asia
country Thailand
Thailand
content_provider Chiang Mai University Library
collection CMU Intellectual Repository
topic Medicine
spellingShingle Medicine
Prapasri Kulalert
Phichayut Phinyo
Jayanton Patumanond
Chutima Smathakanee
Wantida Chuenjit
Sira Nanthapisal
Factors associated with failure of intermittent nebulization with short-acting beta-agonists in children with severe asthma exacerbation
description © 2020 Kulalert et al. Purpose: Intermittent nebulization of short-acting beta-agonists (SABA) is the initial treatment of choice for children with asthma exacerbation. However, children with severe asthma exacerbation (SAE) may not show an adequate response and need aggressive stepwise therapy. We aimed to explore factors associated with a poor response to intermittent nebulized SABA in children with SAE. Methods: A retrospective cohort study of children with SAE diagnosed according to the definition of the British Guidelines on the Management of Asthma, who were admitted at Hat Yai Hospital from January 1, 2015, to December 31, 2017. All children were treated with intermittent SABA nebulization. Treatment failure was defined as children needing escalated therapy. Logistic regression with confounding score adjustment was used to explore the predictors of treatment failure. Results: One hundred thirty-three children were included in the analysis, 59 were in the failure group and 74 were in the success group. After adjusting for potential confounders, they were significantly associated with a previous history of intubation (adjusted OR 6.46, 95% CI 1.13 to 36.79, p=0.036), receiving <3 doses of nebulized salbutamol in the emergency room (ER, aOR 3.21, 95% CI 1.15 to 9.02, p=0.027), ER measured oxygen saturation (SpO2) <92% (adjusted OR 3.02, 95% CI 1.18 to 7.75, p=0.022), and exacerbation triggered by pneumonia (adjusted OR 2.67, 95% CI 1.19 to 6.00, p=0.017). Conclusion: We identified four prognostic factors of treatment failure in children with SAE: a previous history of intubation; receiving <3 doses of nebulized salbutamol in the ER, SpO2 at ER <92%; and exacerbation triggered by pneumonia. Further prospective studies are required to confirm our findings before clinical implementation.
format Journal
author Prapasri Kulalert
Phichayut Phinyo
Jayanton Patumanond
Chutima Smathakanee
Wantida Chuenjit
Sira Nanthapisal
author_facet Prapasri Kulalert
Phichayut Phinyo
Jayanton Patumanond
Chutima Smathakanee
Wantida Chuenjit
Sira Nanthapisal
author_sort Prapasri Kulalert
title Factors associated with failure of intermittent nebulization with short-acting beta-agonists in children with severe asthma exacerbation
title_short Factors associated with failure of intermittent nebulization with short-acting beta-agonists in children with severe asthma exacerbation
title_full Factors associated with failure of intermittent nebulization with short-acting beta-agonists in children with severe asthma exacerbation
title_fullStr Factors associated with failure of intermittent nebulization with short-acting beta-agonists in children with severe asthma exacerbation
title_full_unstemmed Factors associated with failure of intermittent nebulization with short-acting beta-agonists in children with severe asthma exacerbation
title_sort factors associated with failure of intermittent nebulization with short-acting beta-agonists in children with severe asthma exacerbation
publishDate 2020
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85090607376&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/70955
_version_ 1681752996937990144