Development and evaluation of microfluidic device for the determination of organophosphorus pesticide incorporating monolith based immobilized AChE with spectrophotometric detection

A spectrophotometric microfluidic bioreactor system is described for the determination of organophosphorus pesticides. The glass chip was designed and fabricated for in situ monolithic preparation and subsequently acetlycholineserase (AChE) immobilization via a covalent bonding method. The porous po...

Full description

Saved in:
Bibliographic Details
Main Authors: Rattanakit P., Greenway G.M., Liawruangrath S.
Format: Article
Language:English
Published: 2014
Online Access:http://www.scopus.com/inward/record.url?eid=2-s2.0-84878149545&partnerID=40&md5=6a9929cbd669b6b7d99e03821fc2aec1
http://cmuir.cmu.ac.th/handle/6653943832/7377
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
Language: English
id th-cmuir.6653943832-7377
record_format dspace
spelling th-cmuir.6653943832-73772014-08-30T04:00:55Z Development and evaluation of microfluidic device for the determination of organophosphorus pesticide incorporating monolith based immobilized AChE with spectrophotometric detection Rattanakit P. Greenway G.M. Liawruangrath S. A spectrophotometric microfluidic bioreactor system is described for the determination of organophosphorus pesticides. The glass chip was designed and fabricated for in situ monolithic preparation and subsequently acetlycholineserase (AChE) immobilization via a covalent bonding method. The porous polymer monolith was prepared using glycidyl methacrylate, ethylenedimethacrylate and 2,2-dimethoxy-1,2-diphenylethan-1-one in binary porogenic solvents of cyclohexanol and dodecanol. The epoxide groups of monolith were reacted with ethylenediamine and gluteraldehyde to allow immobilization of the enzyme using their amine groups. Organophosphorus pesticides can be determined by measuring their inhibition effect on the enzyme AChE using Ellman's reaction. A linear relationship between the absorbance and percentage inhibitions was obtained over the concentration range of 0.25 to 2.50 mg L-1 paraoxon with a correlation coefficient (r2) of 0.9974. The limit of detection (LOD) defined as 10% inhibition (I10) was 0.17 mg L-1 for paraoxon. The relative standard deviations (RSD) of 1.0 mg L-1 paraoxon was 3.73% (n = 5). The proposed μFI system incorporates efficient enzyme immobilization and reduces reagent consumption and waste production and could thus be considered to be more environmentally friendly. © 2013 Copyright Taylor and Francis Group, LLC. 2014-08-30T04:00:55Z 2014-08-30T04:00:55Z 2013 Article 03067319 10.1080/03067319.2012.755620 IJEAC http://www.scopus.com/inward/record.url?eid=2-s2.0-84878149545&partnerID=40&md5=6a9929cbd669b6b7d99e03821fc2aec1 http://cmuir.cmu.ac.th/handle/6653943832/7377 English
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
language English
description A spectrophotometric microfluidic bioreactor system is described for the determination of organophosphorus pesticides. The glass chip was designed and fabricated for in situ monolithic preparation and subsequently acetlycholineserase (AChE) immobilization via a covalent bonding method. The porous polymer monolith was prepared using glycidyl methacrylate, ethylenedimethacrylate and 2,2-dimethoxy-1,2-diphenylethan-1-one in binary porogenic solvents of cyclohexanol and dodecanol. The epoxide groups of monolith were reacted with ethylenediamine and gluteraldehyde to allow immobilization of the enzyme using their amine groups. Organophosphorus pesticides can be determined by measuring their inhibition effect on the enzyme AChE using Ellman's reaction. A linear relationship between the absorbance and percentage inhibitions was obtained over the concentration range of 0.25 to 2.50 mg L-1 paraoxon with a correlation coefficient (r2) of 0.9974. The limit of detection (LOD) defined as 10% inhibition (I10) was 0.17 mg L-1 for paraoxon. The relative standard deviations (RSD) of 1.0 mg L-1 paraoxon was 3.73% (n = 5). The proposed μFI system incorporates efficient enzyme immobilization and reduces reagent consumption and waste production and could thus be considered to be more environmentally friendly. © 2013 Copyright Taylor and Francis Group, LLC.
format Article
author Rattanakit P.
Greenway G.M.
Liawruangrath S.
spellingShingle Rattanakit P.
Greenway G.M.
Liawruangrath S.
Development and evaluation of microfluidic device for the determination of organophosphorus pesticide incorporating monolith based immobilized AChE with spectrophotometric detection
author_facet Rattanakit P.
Greenway G.M.
Liawruangrath S.
author_sort Rattanakit P.
title Development and evaluation of microfluidic device for the determination of organophosphorus pesticide incorporating monolith based immobilized AChE with spectrophotometric detection
title_short Development and evaluation of microfluidic device for the determination of organophosphorus pesticide incorporating monolith based immobilized AChE with spectrophotometric detection
title_full Development and evaluation of microfluidic device for the determination of organophosphorus pesticide incorporating monolith based immobilized AChE with spectrophotometric detection
title_fullStr Development and evaluation of microfluidic device for the determination of organophosphorus pesticide incorporating monolith based immobilized AChE with spectrophotometric detection
title_full_unstemmed Development and evaluation of microfluidic device for the determination of organophosphorus pesticide incorporating monolith based immobilized AChE with spectrophotometric detection
title_sort development and evaluation of microfluidic device for the determination of organophosphorus pesticide incorporating monolith based immobilized ache with spectrophotometric detection
publishDate 2014
url http://www.scopus.com/inward/record.url?eid=2-s2.0-84878149545&partnerID=40&md5=6a9929cbd669b6b7d99e03821fc2aec1
http://cmuir.cmu.ac.th/handle/6653943832/7377
_version_ 1681420788612202496