Reliability of muscle function and sensory perception measurements of the wrist extensors

This study determined the reliability of muscle function and sensory perception measures of the wrist extensors. The test-retest reliability of the measurements was determined by an intraclass correlation coefficient (ICC), coefficient of variation (CV), standard error of measurements (SEMs), and on...

Full description

Saved in:
Bibliographic Details
Main Authors: Khamwong P., Nosaka K., Pirunsan U., Paungmali A.
Format: Article
Language:English
Published: 2014
Online Access:http://www.scopus.com/inward/record.url?eid=2-s2.0-77955003834&partnerID=40&md5=65ef3dcb7fe4f5d212192d2b671553f2
http://www.ncbi.nlm.nih.gov/pubmed/20658927
http://cmuir.cmu.ac.th/handle/6653943832/744
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
Language: English
id th-cmuir.6653943832-744
record_format dspace
spelling th-cmuir.6653943832-7442014-08-29T09:02:03Z Reliability of muscle function and sensory perception measurements of the wrist extensors Khamwong P. Nosaka K. Pirunsan U. Paungmali A. This study determined the reliability of muscle function and sensory perception measures of the wrist extensors. The test-retest reliability of the measurements was determined by an intraclass correlation coefficient (ICC), coefficient of variation (CV), standard error of measurements (SEMs), and one-way repeated measures ANOVA using the values collected from 25 young (20.6±1.3 years) healthy male volunteers on two occasions separated by 1 day. The measures consisted of grip strength, wrist extension strength (WES), range of motion in active and passive wrist flexion and extension, choice reaction time (CRT), vibration sense (VIB), joint position error sense (JPE), cold pain (CP) and heat pain threshold, and pressure pain threshold. An acceptable reliability was determined as the ICC values greater than 0.85, CV less than 15%, and SEMs less than 5%. ICC of all measures except for JPE were greater than 0.85, only CV of JPE, CP, and VIB exceeded 15%, SEMs were higher than 5% only for JPE and CP, and the ANOVA showed a significant time effect for CRT and WES. It is concluded that most of the measurements except JPE are reliable and can be used to investigate effects of a physiotherapy intervention on the wrist extensors. © 2010 Informa UK Ltd. 2014-08-29T09:02:03Z 2014-08-29T09:02:03Z 2010 Article 9593985 10.3109/09593980903300470 20658927 PTHPE http://www.scopus.com/inward/record.url?eid=2-s2.0-77955003834&partnerID=40&md5=65ef3dcb7fe4f5d212192d2b671553f2 http://www.ncbi.nlm.nih.gov/pubmed/20658927 http://cmuir.cmu.ac.th/handle/6653943832/744 English
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
language English
description This study determined the reliability of muscle function and sensory perception measures of the wrist extensors. The test-retest reliability of the measurements was determined by an intraclass correlation coefficient (ICC), coefficient of variation (CV), standard error of measurements (SEMs), and one-way repeated measures ANOVA using the values collected from 25 young (20.6±1.3 years) healthy male volunteers on two occasions separated by 1 day. The measures consisted of grip strength, wrist extension strength (WES), range of motion in active and passive wrist flexion and extension, choice reaction time (CRT), vibration sense (VIB), joint position error sense (JPE), cold pain (CP) and heat pain threshold, and pressure pain threshold. An acceptable reliability was determined as the ICC values greater than 0.85, CV less than 15%, and SEMs less than 5%. ICC of all measures except for JPE were greater than 0.85, only CV of JPE, CP, and VIB exceeded 15%, SEMs were higher than 5% only for JPE and CP, and the ANOVA showed a significant time effect for CRT and WES. It is concluded that most of the measurements except JPE are reliable and can be used to investigate effects of a physiotherapy intervention on the wrist extensors. © 2010 Informa UK Ltd.
format Article
author Khamwong P.
Nosaka K.
Pirunsan U.
Paungmali A.
spellingShingle Khamwong P.
Nosaka K.
Pirunsan U.
Paungmali A.
Reliability of muscle function and sensory perception measurements of the wrist extensors
author_facet Khamwong P.
Nosaka K.
Pirunsan U.
Paungmali A.
author_sort Khamwong P.
title Reliability of muscle function and sensory perception measurements of the wrist extensors
title_short Reliability of muscle function and sensory perception measurements of the wrist extensors
title_full Reliability of muscle function and sensory perception measurements of the wrist extensors
title_fullStr Reliability of muscle function and sensory perception measurements of the wrist extensors
title_full_unstemmed Reliability of muscle function and sensory perception measurements of the wrist extensors
title_sort reliability of muscle function and sensory perception measurements of the wrist extensors
publishDate 2014
url http://www.scopus.com/inward/record.url?eid=2-s2.0-77955003834&partnerID=40&md5=65ef3dcb7fe4f5d212192d2b671553f2
http://www.ncbi.nlm.nih.gov/pubmed/20658927
http://cmuir.cmu.ac.th/handle/6653943832/744
_version_ 1681419540634796032