Estimation of surface dose from therapeutic 6 MV photon beams

Thesis (D.Eng.)--Chulalongkorn University, 2012

Saved in:
Bibliographic Details
Main Author: Lukkana Apipunyasopon
Other Authors: Nakorn Phaisangittisakul
Format: Theses and Dissertations
Language:English
Published: Chulalongkorn University 2013
Subjects:
Online Access:http://cuir.car.chula.ac.th/handle/123456789/37396
http://doi.org/10.14457/CU.the.2012.937
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chulalongkorn University
Language: English
id th-cuir.37396
record_format dspace
institution Chulalongkorn University
building Chulalongkorn University Library
continent Asia
country Thailand
Thailand
content_provider Chulalongkorn University Library
collection Chulalongkorn University Intellectual Repository
language English
topic Radiotherapy
Skin -- Diseases -- Radiotherapy
Photon beams -- Therapeutic use -- Testing
การรักษาด้วยรังสี
ผิวหนัง -- โรค -- การรักษาด้วยรังสี
รังสีโฟตอน -- การใช้รักษา -- การทดสอบ
spellingShingle Radiotherapy
Skin -- Diseases -- Radiotherapy
Photon beams -- Therapeutic use -- Testing
การรักษาด้วยรังสี
ผิวหนัง -- โรค -- การรักษาด้วยรังสี
รังสีโฟตอน -- การใช้รักษา -- การทดสอบ
Lukkana Apipunyasopon
Estimation of surface dose from therapeutic 6 MV photon beams
description Thesis (D.Eng.)--Chulalongkorn University, 2012
author2 Nakorn Phaisangittisakul
author_facet Nakorn Phaisangittisakul
Lukkana Apipunyasopon
format Theses and Dissertations
author Lukkana Apipunyasopon
author_sort Lukkana Apipunyasopon
title Estimation of surface dose from therapeutic 6 MV photon beams
title_short Estimation of surface dose from therapeutic 6 MV photon beams
title_full Estimation of surface dose from therapeutic 6 MV photon beams
title_fullStr Estimation of surface dose from therapeutic 6 MV photon beams
title_full_unstemmed Estimation of surface dose from therapeutic 6 MV photon beams
title_sort estimation of surface dose from therapeutic 6 mv photon beams
publisher Chulalongkorn University
publishDate 2013
url http://cuir.car.chula.ac.th/handle/123456789/37396
http://doi.org/10.14457/CU.the.2012.937
_version_ 1724630087270137856
spelling th-cuir.373962019-09-18T06:48:59Z Estimation of surface dose from therapeutic 6 MV photon beams การประเมินค่าปริมาณรังสีที่ผิวจากการฉายรังสีโฟตอนพลังงาน 6 เมกะโวลต์ Lukkana Apipunyasopon Nakorn Phaisangittisakul Somyot Srisatit Chulalongkorn University. Faculty of Engineering Radiotherapy Skin -- Diseases -- Radiotherapy Photon beams -- Therapeutic use -- Testing การรักษาด้วยรังสี ผิวหนัง -- โรค -- การรักษาด้วยรังสี รังสีโฟตอน -- การใช้รักษา -- การทดสอบ Thesis (D.Eng.)--Chulalongkorn University, 2012 Accurate assessment of surface dose from therapeutic photon beam can lead to predict the skin reaction and design the radiation treatment technique. Many common dosimeters have been used to estimate the surface dose. However, they are known to over-response in the near surface region. In this study, the surface dose at the central axis of 6 MV photon beams from Varian Clinac 23EX medical linear accelerator was investigated using both measurement and simulation. The photon beams are in square and rectangular shape with the side ranging from 3 to 25 cm defined by the collimators. The measurements were taken using four detectors: TLD chip, PFD[superscript 3G] diode, Markus parallel-plate and CC13 cylindrical ionization chamber. The EGS4nrc Monte Carlo (MC) code was used in the simulation. The surface dose was obtained from an extrapolation of absorbed dose in the near surface region. It was found to be significantly increased almost linearly with the increasing square field size from both measured and simulated results. As expected, the surface dose from the measurement was higher than the simulated result. The lowest and highest over-responses in the surface dose measurement, compared with MC simulation, were found with the TLD chip and the CC13 chamber, respectively. Using the MC result as a gold standard, the correction factors for each dosimeter for estimating the surface dose from square photon beam with the side between 5 to 20 cm were introduced. For the rectangular field, its surface dose can also be obtained from that of the square field using the equivalent square approach. Specifically, the side of the equivalent square of rectangular field was computed using the area-to-perimeter formula. In the comparison between the percentage surface dose of rectangular field and that of the relevant equivalent square, the difference was found to be clinically negligible. Moreover, the influence of collimator scatter on the surface dose was also found to be insignificant. Hence, the surface dose of various rectangular fields from therapeutic photon beam can be predicted reliably using the approach proposed in this study. เนื่องจากในปัจจุบันมีการนำรังสีมาใช้ประโยชน์ในการรักษาด้านการแพทย์เพิ่มขึ้น การทราบค่าปริมาณรังสีที่ผิวได้รับอย่างถูกต้องจึงมีส่วนช่วยในการกำหนดเทคนิคการรักษา และค่าปริมาณรังสีโดยรวมที่จะให้กับผู้ป่วย รวมถึงบอกผลกระทบที่อาจเกิดกับผิวจากการรับรังสีได้ โดยทั่วไปการประเมินค่าปริมาณรังสีที่ผิวทำโดยการวัดด้วยหัววัดรังสีชนิดต่างๆ อย่างไรก็ตามจากการปนเปื้อนของอิเลคตรอนที่บริเวณความลึกใกล้ผิว ทำให้ค่านับวัดที่ได้จากหัววัดรังสีมากเกินความจริง ในการศึกษาครั้งนี้จึงได้ทำการหาค่าปริมาณรังสีที่ผิวจากเครื่องเร่งอนุภาคที่พลังงานรังสีโฟตอน 6 เมกะโวลต์ ในขนาดพื้นที่ลำรังสีตั้งแต่ 3 จนถึง 25 เซนติเมตร ตามแนวกึ่งกลางลำรังสีด้วยวิธีการจำลองด้วยโปรแกรม EGS4nrc Monte Carlo เทคนิค และการวัดด้วยหัววัดรังสีชนิดต่างๆ ได้แก่ หัววัดรังสีชนิดบรรจุก๊าซ (CC13 dosimeter and Markus chamber), หัววัดรังสีชนิดสารกึ่งตัวนำ (PFD[superscript 3G] dosimeter) และหัววัดรังสีชนิดสารเรืองแสง (TLD chip) หาค่าปริมาณรังสีที่ผิวด้วยการลากเส้นแนวโน้มของชุดข้อมูลที่ได้จากทั้งการคำนวณ และการวัดที่ความลึกใกล้ผิว จากการศึกษาพบว่าค่าปริมาณรังสีที่ผิวทั้งจากการคำนวณ และการวัดพบว่ามีค่าเพิ่มขึ้นอย่างมีนัยยะสำคัญเมื่อเพิ่มขนาดพื้นที่ของลำรังสีตกกระทบ โดยค่าปริมาณรังสีที่ผิวจากการวัดจะมีค่ามากกว่าจากการคำนวณ เพื่อให้การประเมินค่าปริมาณรังสีที่ผิวจากการวัดในช่วงขนาดพื้นที่ลำรังสี 5 ถึง 20 เซนติเมตรมีความถูกต้อง จึงได้ทำการกำหนดค่าแก้เนื่องจากปริมาณรังสีที่วัดได้มากเกินจริงสำหรับหัววัดรังสีแต่ละชนิด โดยหัววัดรังสีที่ให้ค่านับวัดมากเกินจริงน้อยที่สุด และมากที่สุดในการศึกษานี้คือ TLD chip และ CC13 dosimeter ตามลำดับ สำหรับในขนาดพื้นที่ลำรังสีใดๆ สามารถคำนวณหาค่าปริมาณรังสีที่ผิวได้โดยการหาพื้นที่เทียบเท่าพื้นที่จัตุรัสด้วยสูตรพื้นที่ต่อเส้นรอบวง เมื่อทำการเปรียบเทียบค่าปริมาณรังสีที่ผิวจากการคำนวณในพื้นที่นั้นๆ รวมถึงการสลับแกน กับการหาพื้นที่เทียบเท่าพื้นที่จัตุรัสพบว่าค่าความแตกต่างอยู่ในระดับที่ยอมรับได้ ดังนั้นค่าปริมาณรังสีที่ผิวในพื้นที่ลำรังสีใดๆ สามารถประเมินได้อย่างน่าเชื่อถือด้วยวิธีการที่ใช้ในการศึกษานี้ 2013-12-09T07:57:24Z 2013-12-09T07:57:24Z 2012 Thesis http://cuir.car.chula.ac.th/handle/123456789/37396 10.14457/CU.the.2012.937 en http://doi.org/10.14457/CU.the.2012.937 Chulalongkorn University application/pdf Chulalongkorn University