Flow cytometric CD4 enumeration of four different HIV-infected blood samples at the cost of one monoclonal antibody reagent

Background: The frequency and absolute number of CD4 + T-lymphocytes continue to be one of the major clinical markers for management of HIV/AIDS. The present standard dual-platform (DP) three-color and two-color PanLeucogating flow cytometric (FCM) methods for most developing countries are either ex...

Full description

Saved in:
Bibliographic Details
Main Authors: Egarit Noulsri, Surada Lerdwana, Kasama Sukapirom, Charin Thepthai, Nattawat Onlamoon, Boonrat Tassaneetrithep, Kovit Pattanapanyasat
Other Authors: Mahidol University
Format: Article
Published: 2018
Subjects:
Online Access:https://repository.li.mahidol.ac.th/handle/123456789/12037
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Mahidol University
id th-mahidol.12037
record_format dspace
spelling th-mahidol.120372018-05-03T15:31:06Z Flow cytometric CD4 enumeration of four different HIV-infected blood samples at the cost of one monoclonal antibody reagent Egarit Noulsri Surada Lerdwana Kasama Sukapirom Charin Thepthai Nattawat Onlamoon Boonrat Tassaneetrithep Kovit Pattanapanyasat Mahidol University Immunology and Microbiology Medicine Background: The frequency and absolute number of CD4 + T-lymphocytes continue to be one of the major clinical markers for management of HIV/AIDS. The present standard dual-platform (DP) three-color and two-color PanLeucogating flow cytometric (FCM) methods for most developing countries are either expensive if manufacturers' monoclonal antibody reagents are used or limited due to an insufficient supply of generic reagents. Clearly, more affordable FCM methods are needed. Objective: To develop a novel DP FCM method using biotin-streptavidin-fluorochrome labeling in combination with the two standard DP methods for 4 different white blood cells (WBC) using only one monoclonal antibody reagent. Methods: The percentage of CD4 + T-lymphocytes in 116 HIV-infected blood samples was determined using our new method. Results were compared with the two standard methods. Correlation and agreement of the pair method were determined using linear regression, Bland- Altman and percent similarity analysis. Results: Our study showed that percentage of CD4 + T-lymphocyte values obtained from the new method correlated highly with the standard three-color and the two-color methods (r 2 = 0.95 {n = 52} and 0.97 {n = 64}). The mean bias and percent similarity for the new method compared with the two standard methods were -0.53% (limit of agreement {LOA}:-5.22% to +4.16% with percent similarity of 99.28; and -0.22% with LOA of -3.42% to +2.98%, the percent similarity of 98.15, respectively. Conclusions: Our FCM method using biotin to label 4 different WBC samples followed by streptavidin staining is reliable for determination of CD4 + T-lymphocytes. Such an approach will significantly reduce the cost for monitoring HIVinfected patients in resource-limited settings. 2018-05-03T08:16:19Z 2018-05-03T08:16:19Z 2011-06-01 Article Asian Pacific Journal of Allergy and Immunology. Vol.29, No.2 (2011), 190-199 22288694 0125877X 2-s2.0-79959432834 https://repository.li.mahidol.ac.th/handle/123456789/12037 Mahidol University SCOPUS https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79959432834&origin=inward
institution Mahidol University
building Mahidol University Library
continent Asia
country Thailand
Thailand
content_provider Mahidol University Library
collection Mahidol University Institutional Repository
topic Immunology and Microbiology
Medicine
spellingShingle Immunology and Microbiology
Medicine
Egarit Noulsri
Surada Lerdwana
Kasama Sukapirom
Charin Thepthai
Nattawat Onlamoon
Boonrat Tassaneetrithep
Kovit Pattanapanyasat
Flow cytometric CD4 enumeration of four different HIV-infected blood samples at the cost of one monoclonal antibody reagent
description Background: The frequency and absolute number of CD4 + T-lymphocytes continue to be one of the major clinical markers for management of HIV/AIDS. The present standard dual-platform (DP) three-color and two-color PanLeucogating flow cytometric (FCM) methods for most developing countries are either expensive if manufacturers' monoclonal antibody reagents are used or limited due to an insufficient supply of generic reagents. Clearly, more affordable FCM methods are needed. Objective: To develop a novel DP FCM method using biotin-streptavidin-fluorochrome labeling in combination with the two standard DP methods for 4 different white blood cells (WBC) using only one monoclonal antibody reagent. Methods: The percentage of CD4 + T-lymphocytes in 116 HIV-infected blood samples was determined using our new method. Results were compared with the two standard methods. Correlation and agreement of the pair method were determined using linear regression, Bland- Altman and percent similarity analysis. Results: Our study showed that percentage of CD4 + T-lymphocyte values obtained from the new method correlated highly with the standard three-color and the two-color methods (r 2 = 0.95 {n = 52} and 0.97 {n = 64}). The mean bias and percent similarity for the new method compared with the two standard methods were -0.53% (limit of agreement {LOA}:-5.22% to +4.16% with percent similarity of 99.28; and -0.22% with LOA of -3.42% to +2.98%, the percent similarity of 98.15, respectively. Conclusions: Our FCM method using biotin to label 4 different WBC samples followed by streptavidin staining is reliable for determination of CD4 + T-lymphocytes. Such an approach will significantly reduce the cost for monitoring HIVinfected patients in resource-limited settings.
author2 Mahidol University
author_facet Mahidol University
Egarit Noulsri
Surada Lerdwana
Kasama Sukapirom
Charin Thepthai
Nattawat Onlamoon
Boonrat Tassaneetrithep
Kovit Pattanapanyasat
format Article
author Egarit Noulsri
Surada Lerdwana
Kasama Sukapirom
Charin Thepthai
Nattawat Onlamoon
Boonrat Tassaneetrithep
Kovit Pattanapanyasat
author_sort Egarit Noulsri
title Flow cytometric CD4 enumeration of four different HIV-infected blood samples at the cost of one monoclonal antibody reagent
title_short Flow cytometric CD4 enumeration of four different HIV-infected blood samples at the cost of one monoclonal antibody reagent
title_full Flow cytometric CD4 enumeration of four different HIV-infected blood samples at the cost of one monoclonal antibody reagent
title_fullStr Flow cytometric CD4 enumeration of four different HIV-infected blood samples at the cost of one monoclonal antibody reagent
title_full_unstemmed Flow cytometric CD4 enumeration of four different HIV-infected blood samples at the cost of one monoclonal antibody reagent
title_sort flow cytometric cd4 enumeration of four different hiv-infected blood samples at the cost of one monoclonal antibody reagent
publishDate 2018
url https://repository.li.mahidol.ac.th/handle/123456789/12037
_version_ 1763495832014815232