Mismatch analysis of humeral nailing: Antegrade versus retrograde insertion
Background Closed humeral nailing is now considered an alternative treatment for humeral-shaft fracture. The nail can be inserted with either the antegrade or retrograde method. We investigated and compared the problem of geometric mismatch of the humeral nail to the humerus between the two methods...
Saved in:
Main Authors: | , , , , , |
---|---|
Other Authors: | |
Format: | Article |
Published: |
2018
|
Subjects: | |
Online Access: | https://repository.li.mahidol.ac.th/handle/123456789/12764 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Mahidol University |
id |
th-mahidol.12764 |
---|---|
record_format |
dspace |
spelling |
th-mahidol.127642018-05-03T15:39:05Z Mismatch analysis of humeral nailing: Antegrade versus retrograde insertion Banchong Mahaisavariya Pongnarin Jiamwatthanachai Panya Aroonjarattham Kitti Aroonjarattham Marut Wongcumchang Kriskrai Sitthiseripratip Mahidol University Kasetsart University Burapha University Thailand National Metal and Materials Technology Center Medicine Background Closed humeral nailing is now considered an alternative treatment for humeral-shaft fracture. The nail can be inserted with either the antegrade or retrograde method. We investigated and compared the problem of geometric mismatch of the humeral nail to the humerus between the two methods of insertion. Methods The study was performed using virtual simulation based on computed tomography (CT) data of 76 Thai cadaveric humeri and the commonly used Russell-Taylor humeral nail 8 mm in diameter and 220 mm long. Mismatch of the nail to the intact humerus was analyzed and compared between the antegrade and retrograde nailing approaches. Results The results showed: (1) the diameter of the medullary canal averaged 7.9-13.8 mm; (2) the minimal reaming diameter to accommodate virtual nail insertion averaged 8.8-14.8 mm for the antegrade and 8.8-29.3 mm for the retrograde approach; (3) the minimal reaming thickness of the inner cortex averaged 0.1-1.5 mm for the antegrade and 0.1-9.9 mm for the retrograde approach; (4) the percentages of cortical bone removed prior to nail insertion were 3.8-107.1% and 3.8-1,287.6% for the antegrade and retrograde approaches, respectively; (5) the eccentricity of the nail-medullary canal center were 0.4-3.4 and 0.4-10.6 mm for the antegrade and retrograde approaches, respectively. Conclusions Less mismatching occurred with antegrade nailing than with the retrograde approach. Retrograde nailing requires excessive reaming at the distal part of the humerus to accommodate nail insertion. This may create bone weakness and the risk of supracondylar fracture. © The Japanese Orthopaedic Association 2011. 2018-05-03T08:39:05Z 2018-05-03T08:39:05Z 2011-01-01 Article Journal of Orthopaedic Science. Vol.16, No.5 (2011), 644-651 10.1007/s00776-011-0127-2 14362023 09492658 2-s2.0-82955162751 https://repository.li.mahidol.ac.th/handle/123456789/12764 Mahidol University SCOPUS https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=82955162751&origin=inward |
institution |
Mahidol University |
building |
Mahidol University Library |
continent |
Asia |
country |
Thailand Thailand |
content_provider |
Mahidol University Library |
collection |
Mahidol University Institutional Repository |
topic |
Medicine |
spellingShingle |
Medicine Banchong Mahaisavariya Pongnarin Jiamwatthanachai Panya Aroonjarattham Kitti Aroonjarattham Marut Wongcumchang Kriskrai Sitthiseripratip Mismatch analysis of humeral nailing: Antegrade versus retrograde insertion |
description |
Background Closed humeral nailing is now considered an alternative treatment for humeral-shaft fracture. The nail can be inserted with either the antegrade or retrograde method. We investigated and compared the problem of geometric mismatch of the humeral nail to the humerus between the two methods of insertion. Methods The study was performed using virtual simulation based on computed tomography (CT) data of 76 Thai cadaveric humeri and the commonly used Russell-Taylor humeral nail 8 mm in diameter and 220 mm long. Mismatch of the nail to the intact humerus was analyzed and compared between the antegrade and retrograde nailing approaches. Results The results showed: (1) the diameter of the medullary canal averaged 7.9-13.8 mm; (2) the minimal reaming diameter to accommodate virtual nail insertion averaged 8.8-14.8 mm for the antegrade and 8.8-29.3 mm for the retrograde approach; (3) the minimal reaming thickness of the inner cortex averaged 0.1-1.5 mm for the antegrade and 0.1-9.9 mm for the retrograde approach; (4) the percentages of cortical bone removed prior to nail insertion were 3.8-107.1% and 3.8-1,287.6% for the antegrade and retrograde approaches, respectively; (5) the eccentricity of the nail-medullary canal center were 0.4-3.4 and 0.4-10.6 mm for the antegrade and retrograde approaches, respectively. Conclusions Less mismatching occurred with antegrade nailing than with the retrograde approach. Retrograde nailing requires excessive reaming at the distal part of the humerus to accommodate nail insertion. This may create bone weakness and the risk of supracondylar fracture. © The Japanese Orthopaedic Association 2011. |
author2 |
Mahidol University |
author_facet |
Mahidol University Banchong Mahaisavariya Pongnarin Jiamwatthanachai Panya Aroonjarattham Kitti Aroonjarattham Marut Wongcumchang Kriskrai Sitthiseripratip |
format |
Article |
author |
Banchong Mahaisavariya Pongnarin Jiamwatthanachai Panya Aroonjarattham Kitti Aroonjarattham Marut Wongcumchang Kriskrai Sitthiseripratip |
author_sort |
Banchong Mahaisavariya |
title |
Mismatch analysis of humeral nailing: Antegrade versus retrograde insertion |
title_short |
Mismatch analysis of humeral nailing: Antegrade versus retrograde insertion |
title_full |
Mismatch analysis of humeral nailing: Antegrade versus retrograde insertion |
title_fullStr |
Mismatch analysis of humeral nailing: Antegrade versus retrograde insertion |
title_full_unstemmed |
Mismatch analysis of humeral nailing: Antegrade versus retrograde insertion |
title_sort |
mismatch analysis of humeral nailing: antegrade versus retrograde insertion |
publishDate |
2018 |
url |
https://repository.li.mahidol.ac.th/handle/123456789/12764 |
_version_ |
1763493027533291520 |