Comparison of corneal astigmatism and axis location in cataract patients measured by total corneal power, automated keratometry, and simulated keratometry

Purpose: To compare the corneal astigmatism (magnitude and axis location) derived by total corneal power (TCP), automated keratometry, and simulated keratometry. Setting: Siriraj Hospital, Mahidol University, Bangkok, Thailand. Design: Prospective comparative study. Methods: Eyes with previous ocula...

Full description

Saved in:
Bibliographic Details
Main Authors: Sabong Srivannaboon, Soeharnila, Chareenun Chirapapaisan, Pratuangsri Chonpimai
Other Authors: Mahidol University
Format: Article
Published: 2018
Subjects:
Online Access:https://repository.li.mahidol.ac.th/handle/123456789/14478
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Mahidol University
id th-mahidol.14478
record_format dspace
spelling th-mahidol.144782018-06-11T12:21:09Z Comparison of corneal astigmatism and axis location in cataract patients measured by total corneal power, automated keratometry, and simulated keratometry Sabong Srivannaboon Soeharnila Chareenun Chirapapaisan Pratuangsri Chonpimai Mahidol University Faculty of Medicine, Siriraj Hospital, Mahidol University Klinik Mata Nusantara Medicine Neuroscience Purpose: To compare the corneal astigmatism (magnitude and axis location) derived by total corneal power (TCP), automated keratometry, and simulated keratometry. Setting: Siriraj Hospital, Mahidol University, Bangkok, Thailand. Design: Prospective comparative study. Methods: Eyes with previous ocular surgery or abnormalities were excluded. All patients were examined with the ARK 730A autokeratometer and the Galilei analyzer. The steepest and flattest corneal power along with the steepest axis of the TCP, automated keratometry, and simulated keratometry were recorded. Vector analysis (J0 and J45) was calculated. Analysis of variance with Bonferroni correction was performed for multiple comparisons. Outcome measures were the magnitude and axis location of astigmatism. Results: One hundred eyes of 100 cataract patients were randomly selected. There was no statistically significant difference in the mean steepest axis between TCP (93.31 ± 68.75 [SD]), automated keratometry (94.24 ± 64.78), and simulated keratometry (92.42 ± 64.30). However, the mean magnitude of astigmatism measured by TCP (1.23 ± 0.75) was significantly higher than that measured by automated keratometry (0.93 ± 0.68) (P=.01) but not than that measured by simulated keratometry (1.08 ± 0.68) (P=.43); there was no statistically significant difference in J0 or J45. Twenty two (40%) of 54 eyes with more than 1.00 diopter of TCP astigmatism had more than 10 degrees of axis difference from automated keratometry. Conclusions: The magnitude of TCP astigmatism was higher than that of automated keratometry. The axis location was similar. However, there was more than 10 degrees of axis difference between automated keratometry and TCP in patients with high astigmatism. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned. © 2012 ASCRS and ESCRS. 2018-06-11T05:00:06Z 2018-06-11T05:00:06Z 2012-12-01 Article Journal of Cataract and Refractive Surgery. Vol.38, No.12 (2012), 2088-2093 10.1016/j.jcrs.2012.07.024 18734502 08863350 2-s2.0-84870302417 https://repository.li.mahidol.ac.th/handle/123456789/14478 Mahidol University SCOPUS https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84870302417&origin=inward
institution Mahidol University
building Mahidol University Library
continent Asia
country Thailand
Thailand
content_provider Mahidol University Library
collection Mahidol University Institutional Repository
topic Medicine
Neuroscience
spellingShingle Medicine
Neuroscience
Sabong Srivannaboon
Soeharnila
Chareenun Chirapapaisan
Pratuangsri Chonpimai
Comparison of corneal astigmatism and axis location in cataract patients measured by total corneal power, automated keratometry, and simulated keratometry
description Purpose: To compare the corneal astigmatism (magnitude and axis location) derived by total corneal power (TCP), automated keratometry, and simulated keratometry. Setting: Siriraj Hospital, Mahidol University, Bangkok, Thailand. Design: Prospective comparative study. Methods: Eyes with previous ocular surgery or abnormalities were excluded. All patients were examined with the ARK 730A autokeratometer and the Galilei analyzer. The steepest and flattest corneal power along with the steepest axis of the TCP, automated keratometry, and simulated keratometry were recorded. Vector analysis (J0 and J45) was calculated. Analysis of variance with Bonferroni correction was performed for multiple comparisons. Outcome measures were the magnitude and axis location of astigmatism. Results: One hundred eyes of 100 cataract patients were randomly selected. There was no statistically significant difference in the mean steepest axis between TCP (93.31 ± 68.75 [SD]), automated keratometry (94.24 ± 64.78), and simulated keratometry (92.42 ± 64.30). However, the mean magnitude of astigmatism measured by TCP (1.23 ± 0.75) was significantly higher than that measured by automated keratometry (0.93 ± 0.68) (P=.01) but not than that measured by simulated keratometry (1.08 ± 0.68) (P=.43); there was no statistically significant difference in J0 or J45. Twenty two (40%) of 54 eyes with more than 1.00 diopter of TCP astigmatism had more than 10 degrees of axis difference from automated keratometry. Conclusions: The magnitude of TCP astigmatism was higher than that of automated keratometry. The axis location was similar. However, there was more than 10 degrees of axis difference between automated keratometry and TCP in patients with high astigmatism. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned. © 2012 ASCRS and ESCRS.
author2 Mahidol University
author_facet Mahidol University
Sabong Srivannaboon
Soeharnila
Chareenun Chirapapaisan
Pratuangsri Chonpimai
format Article
author Sabong Srivannaboon
Soeharnila
Chareenun Chirapapaisan
Pratuangsri Chonpimai
author_sort Sabong Srivannaboon
title Comparison of corneal astigmatism and axis location in cataract patients measured by total corneal power, automated keratometry, and simulated keratometry
title_short Comparison of corneal astigmatism and axis location in cataract patients measured by total corneal power, automated keratometry, and simulated keratometry
title_full Comparison of corneal astigmatism and axis location in cataract patients measured by total corneal power, automated keratometry, and simulated keratometry
title_fullStr Comparison of corneal astigmatism and axis location in cataract patients measured by total corneal power, automated keratometry, and simulated keratometry
title_full_unstemmed Comparison of corneal astigmatism and axis location in cataract patients measured by total corneal power, automated keratometry, and simulated keratometry
title_sort comparison of corneal astigmatism and axis location in cataract patients measured by total corneal power, automated keratometry, and simulated keratometry
publishDate 2018
url https://repository.li.mahidol.ac.th/handle/123456789/14478
_version_ 1763498211818864640