Refractive outcomes of femtosecond LASIK for myopic correction at Siriraj Hospital, Thailand.

To evaluate refractive outcomes of myopic femtosecond LASIK at Siriraj Hospital, Thailand. A retrospective study of patients who underwent femtosecond LASIK at SiLASIK center Siriraj hospital, Mahidol University, Thailand,from April 2009 to April 2010 was conducted. All patients had completely norma...

Full description

Saved in:
Bibliographic Details
Main Authors: Sabong Srivannaboon, Pornlada Sunlakaviset, Panida Kosrirukvongs, Pinnita Prabhasawat, Wipawee Booranapong, Suksri Chotikavanich, Wasin Po-Ngam
Other Authors: Mahidol University
Format: Article
Published: 2018
Subjects:
Online Access:https://repository.li.mahidol.ac.th/handle/123456789/14850
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Mahidol University
Description
Summary:To evaluate refractive outcomes of myopic femtosecond LASIK at Siriraj Hospital, Thailand. A retrospective study of patients who underwent femtosecond LASIK at SiLASIK center Siriraj hospital, Mahidol University, Thailand,from April 2009 to April 2010 was conducted. All patients had completely normal preoperative eye examination. All LASIK procedures were performed using Intralase femtosecond laser (Abbott Medical Optics Inc (AMO)) and VISX star S4 excimer laser (AMO). Postoperative follow-up included visual acuity (ETDRS chart) and manifest refraction at 1 day, 1 week, 1 month and 3 months. The flap thickness was evaluated at 3 months using Visante optical coherence tomography (OCT Carl Zeiss Meditec). One hundred and twenty eight eyes of 64 patients were included in the study. Mean preoperative manifest refraction spherical equivalent (MRSE) was -5.47 +/- 2.28 diopters (range, -1.88 to -12.63 diopters). At 3 months post-operation, the MRSE was -0.26 +/- 0.39 diopters (range, + 0.25 to -2.00 diopters) and 95.31% were within + 1.00 diopter of intended correction. There was 98% of eyes achieved uncorrected distance visual acuity (UDVA) 20/40 or better and 73% achieved UD VA 20/20 or better There was 31% of eyes gained one line and 15% lost 1 line of corrected distance visual acuity (CDVA). The mean error of flap thickness (difference between actual and intended central flap thickness) was + 0.23 +/- 1.77 microm for 120 microm flap setting and + 0.22 +/- 0.97 microm for 110 microm flap setting. The flap morphology was planar configuration. Myopic femtosecond LASIK at Siriraj Hospital provided satisfactory refractive outcomes and high accuracy of the flap thickness.