Effect of attenuation correction on lesion detection using a hybrid PET system
Objective: The purpose of this study was to investigate the effect of attenuation correction (AC) on lesion detection for a hybrid PET system. Material and Method: Experimental list-mode data were acquired from hot spheres inside a uniform cylindrical phantom with an elliptical cross-section using a...
Saved in:
Main Authors: | , , , |
---|---|
Other Authors: | |
Format: | Article |
Published: |
2018
|
Subjects: | |
Online Access: | https://repository.li.mahidol.ac.th/handle/123456789/17130 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Mahidol University |
id |
th-mahidol.17130 |
---|---|
record_format |
dspace |
spelling |
th-mahidol.171302018-06-21T15:32:08Z Effect of attenuation correction on lesion detection using a hybrid PET system Chiraporn Tocharoenchai Benjamin M W Tsui Eric C. Frey Wen Tung Wang Mahidol University Johns Hopkins University University of Virginia Medicine Objective: The purpose of this study was to investigate the effect of attenuation correction (AC) on lesion detection for a hybrid PET system. Material and Method: Experimental list-mode data were acquired from hot spheres inside a uniform cylindrical phantom with an elliptical cross-section using a Siemens E.CAM+ dual-camera hybrid PET system. Spheres with inner diameters of 0.8- and 1-cm and the cylindrical phantom were filled with F-18 to simulate lesions with lesion-to-background (L/B) ratios of 14:1 and 8:1, respectively, found in clinical PET studies. The list-mode data of each sphere size were regrouped into sinograms with peak-to-peak energy window settings at 30% and 20% for the 0.8- and 1-cm diameter lesion, respectively. They were then rebinned using the single slice rebinning method. Attenuation correction was applied assuming uniform attenuation. The sinograms with and without AC were reconstructed using 5 iterations of OS-EM algorithm with 8 angles/subset and postfiltered with a Butterworth filter with n = 5 and fc = 0.52 cycles/cm. Human observer performance study and localization receiver operating characteristic (LROC) analysis were used to evaluate the reconstructed images for maximum lesion detection. Average areas under the LROC curves (ALROC) across 8 observers obtained with and without AC were determined. The null hypothesis that there was no difference between with AC and without AC was tested using a two-tailed t-test with 95% confidence interval. Results: The results indicated that for the 0.8-cm lesion with 14:1 L/B ratio, the ALROC decreases from 0.66 to 0.62 when AC is applied as compared to without AC and from 0.69 to 0.63 for the 1.0-cm lesion with 8:1 L/ B ratio, but no statistical significant difference (p > 0.05). Conclusion: The authors conclude that for a phantom with hot lesions embedded in a uniform background, AC decreases lesion detectability compared to without AC using a hybrid PET system for small lesion sizes. 2018-06-21T08:32:08Z 2018-06-21T08:32:08Z 2005-01-01 Article Journal of the Medical Association of Thailand. Vol.88, No.1 (2005), 96-102 01252208 2-s2.0-20444463971 https://repository.li.mahidol.ac.th/handle/123456789/17130 Mahidol University SCOPUS https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=20444463971&origin=inward |
institution |
Mahidol University |
building |
Mahidol University Library |
continent |
Asia |
country |
Thailand Thailand |
content_provider |
Mahidol University Library |
collection |
Mahidol University Institutional Repository |
topic |
Medicine |
spellingShingle |
Medicine Chiraporn Tocharoenchai Benjamin M W Tsui Eric C. Frey Wen Tung Wang Effect of attenuation correction on lesion detection using a hybrid PET system |
description |
Objective: The purpose of this study was to investigate the effect of attenuation correction (AC) on lesion detection for a hybrid PET system. Material and Method: Experimental list-mode data were acquired from hot spheres inside a uniform cylindrical phantom with an elliptical cross-section using a Siemens E.CAM+ dual-camera hybrid PET system. Spheres with inner diameters of 0.8- and 1-cm and the cylindrical phantom were filled with F-18 to simulate lesions with lesion-to-background (L/B) ratios of 14:1 and 8:1, respectively, found in clinical PET studies. The list-mode data of each sphere size were regrouped into sinograms with peak-to-peak energy window settings at 30% and 20% for the 0.8- and 1-cm diameter lesion, respectively. They were then rebinned using the single slice rebinning method. Attenuation correction was applied assuming uniform attenuation. The sinograms with and without AC were reconstructed using 5 iterations of OS-EM algorithm with 8 angles/subset and postfiltered with a Butterworth filter with n = 5 and fc = 0.52 cycles/cm. Human observer performance study and localization receiver operating characteristic (LROC) analysis were used to evaluate the reconstructed images for maximum lesion detection. Average areas under the LROC curves (ALROC) across 8 observers obtained with and without AC were determined. The null hypothesis that there was no difference between with AC and without AC was tested using a two-tailed t-test with 95% confidence interval. Results: The results indicated that for the 0.8-cm lesion with 14:1 L/B ratio, the ALROC decreases from 0.66 to 0.62 when AC is applied as compared to without AC and from 0.69 to 0.63 for the 1.0-cm lesion with 8:1 L/ B ratio, but no statistical significant difference (p > 0.05). Conclusion: The authors conclude that for a phantom with hot lesions embedded in a uniform background, AC decreases lesion detectability compared to without AC using a hybrid PET system for small lesion sizes. |
author2 |
Mahidol University |
author_facet |
Mahidol University Chiraporn Tocharoenchai Benjamin M W Tsui Eric C. Frey Wen Tung Wang |
format |
Article |
author |
Chiraporn Tocharoenchai Benjamin M W Tsui Eric C. Frey Wen Tung Wang |
author_sort |
Chiraporn Tocharoenchai |
title |
Effect of attenuation correction on lesion detection using a hybrid PET system |
title_short |
Effect of attenuation correction on lesion detection using a hybrid PET system |
title_full |
Effect of attenuation correction on lesion detection using a hybrid PET system |
title_fullStr |
Effect of attenuation correction on lesion detection using a hybrid PET system |
title_full_unstemmed |
Effect of attenuation correction on lesion detection using a hybrid PET system |
title_sort |
effect of attenuation correction on lesion detection using a hybrid pet system |
publishDate |
2018 |
url |
https://repository.li.mahidol.ac.th/handle/123456789/17130 |
_version_ |
1763496075564417024 |