Control Cells for Both Electrical Impedance and Light Scattering Automated Hematological Analyzers: Preparation from Normal and Thalassemic Blood Samples

The study on quality control of automated blood cell analyzers, Technicon H *1 and Coulter MAXM by using three separately self-prepared control cells was extensively investigated. The three parts of control cells are pseudo-leukocyte and fixed platelets, which are fixed by glutaraldehyde, and contro...

Full description

Saved in:
Bibliographic Details
Main Authors: Pasra Arnutti, Ahnond Bunyaratavej, Kovit Patanapanyasat, Ampaiwan Chuansumrit
Other Authors: Pramongkutklao Hospital
Format: Article
Published: 2018
Subjects:
Online Access:https://repository.li.mahidol.ac.th/handle/123456789/18100
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Mahidol University
id th-mahidol.18100
record_format dspace
spelling th-mahidol.181002018-07-04T14:48:44Z Control Cells for Both Electrical Impedance and Light Scattering Automated Hematological Analyzers: Preparation from Normal and Thalassemic Blood Samples Pasra Arnutti Ahnond Bunyaratavej Kovit Patanapanyasat Ampaiwan Chuansumrit Pramongkutklao Hospital Mahidol University Medicine The study on quality control of automated blood cell analyzers, Technicon H *1 and Coulter MAXM by using three separately self-prepared control cells was extensively investigated. The three parts of control cells are pseudo-leukocyte and fixed platelets, which are fixed by glutaraldehyde, and control red cells from normal and thalassemic patients preserved and anticoagulated in CPD or CPDA-I. The Technicon H *1 system was based on the principle of light scattering but the Coulter MAXM was based on the principle of electrical impedance for cell counting and measurement. The self-prepared control cells can be satisfactorily utilized as control for each system with statistically significant difference (p < 0.05) for both systems. The expirated dates for control cells are different in both systems and should be determined for each system specifically. The control red cells prepared from thalassemic patients were quite satisfactorily useful as an abnormal control for both systems during this study. 2018-07-04T07:48:44Z 2018-07-04T07:48:44Z 1997-09-01 Article Journal of the Medical Association of Thailand. Vol.80, No.SUPPL. 1 (1997) 01252208 2-s2.0-0009058783 https://repository.li.mahidol.ac.th/handle/123456789/18100 Mahidol University SCOPUS https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0009058783&origin=inward
institution Mahidol University
building Mahidol University Library
continent Asia
country Thailand
Thailand
content_provider Mahidol University Library
collection Mahidol University Institutional Repository
topic Medicine
spellingShingle Medicine
Pasra Arnutti
Ahnond Bunyaratavej
Kovit Patanapanyasat
Ampaiwan Chuansumrit
Control Cells for Both Electrical Impedance and Light Scattering Automated Hematological Analyzers: Preparation from Normal and Thalassemic Blood Samples
description The study on quality control of automated blood cell analyzers, Technicon H *1 and Coulter MAXM by using three separately self-prepared control cells was extensively investigated. The three parts of control cells are pseudo-leukocyte and fixed platelets, which are fixed by glutaraldehyde, and control red cells from normal and thalassemic patients preserved and anticoagulated in CPD or CPDA-I. The Technicon H *1 system was based on the principle of light scattering but the Coulter MAXM was based on the principle of electrical impedance for cell counting and measurement. The self-prepared control cells can be satisfactorily utilized as control for each system with statistically significant difference (p < 0.05) for both systems. The expirated dates for control cells are different in both systems and should be determined for each system specifically. The control red cells prepared from thalassemic patients were quite satisfactorily useful as an abnormal control for both systems during this study.
author2 Pramongkutklao Hospital
author_facet Pramongkutklao Hospital
Pasra Arnutti
Ahnond Bunyaratavej
Kovit Patanapanyasat
Ampaiwan Chuansumrit
format Article
author Pasra Arnutti
Ahnond Bunyaratavej
Kovit Patanapanyasat
Ampaiwan Chuansumrit
author_sort Pasra Arnutti
title Control Cells for Both Electrical Impedance and Light Scattering Automated Hematological Analyzers: Preparation from Normal and Thalassemic Blood Samples
title_short Control Cells for Both Electrical Impedance and Light Scattering Automated Hematological Analyzers: Preparation from Normal and Thalassemic Blood Samples
title_full Control Cells for Both Electrical Impedance and Light Scattering Automated Hematological Analyzers: Preparation from Normal and Thalassemic Blood Samples
title_fullStr Control Cells for Both Electrical Impedance and Light Scattering Automated Hematological Analyzers: Preparation from Normal and Thalassemic Blood Samples
title_full_unstemmed Control Cells for Both Electrical Impedance and Light Scattering Automated Hematological Analyzers: Preparation from Normal and Thalassemic Blood Samples
title_sort control cells for both electrical impedance and light scattering automated hematological analyzers: preparation from normal and thalassemic blood samples
publishDate 2018
url https://repository.li.mahidol.ac.th/handle/123456789/18100
_version_ 1763494676744110080