Control Cells for Both Electrical Impedance and Light Scattering Automated Hematological Analyzers: Preparation from Normal and Thalassemic Blood Samples
The study on quality control of automated blood cell analyzers, Technicon H *1 and Coulter MAXM by using three separately self-prepared control cells was extensively investigated. The three parts of control cells are pseudo-leukocyte and fixed platelets, which are fixed by glutaraldehyde, and contro...
Saved in:
Main Authors: | , , , |
---|---|
Other Authors: | |
Format: | Article |
Published: |
2018
|
Subjects: | |
Online Access: | https://repository.li.mahidol.ac.th/handle/123456789/18100 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Mahidol University |
id |
th-mahidol.18100 |
---|---|
record_format |
dspace |
spelling |
th-mahidol.181002018-07-04T14:48:44Z Control Cells for Both Electrical Impedance and Light Scattering Automated Hematological Analyzers: Preparation from Normal and Thalassemic Blood Samples Pasra Arnutti Ahnond Bunyaratavej Kovit Patanapanyasat Ampaiwan Chuansumrit Pramongkutklao Hospital Mahidol University Medicine The study on quality control of automated blood cell analyzers, Technicon H *1 and Coulter MAXM by using three separately self-prepared control cells was extensively investigated. The three parts of control cells are pseudo-leukocyte and fixed platelets, which are fixed by glutaraldehyde, and control red cells from normal and thalassemic patients preserved and anticoagulated in CPD or CPDA-I. The Technicon H *1 system was based on the principle of light scattering but the Coulter MAXM was based on the principle of electrical impedance for cell counting and measurement. The self-prepared control cells can be satisfactorily utilized as control for each system with statistically significant difference (p < 0.05) for both systems. The expirated dates for control cells are different in both systems and should be determined for each system specifically. The control red cells prepared from thalassemic patients were quite satisfactorily useful as an abnormal control for both systems during this study. 2018-07-04T07:48:44Z 2018-07-04T07:48:44Z 1997-09-01 Article Journal of the Medical Association of Thailand. Vol.80, No.SUPPL. 1 (1997) 01252208 2-s2.0-0009058783 https://repository.li.mahidol.ac.th/handle/123456789/18100 Mahidol University SCOPUS https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0009058783&origin=inward |
institution |
Mahidol University |
building |
Mahidol University Library |
continent |
Asia |
country |
Thailand Thailand |
content_provider |
Mahidol University Library |
collection |
Mahidol University Institutional Repository |
topic |
Medicine |
spellingShingle |
Medicine Pasra Arnutti Ahnond Bunyaratavej Kovit Patanapanyasat Ampaiwan Chuansumrit Control Cells for Both Electrical Impedance and Light Scattering Automated Hematological Analyzers: Preparation from Normal and Thalassemic Blood Samples |
description |
The study on quality control of automated blood cell analyzers, Technicon H *1 and Coulter MAXM by using three separately self-prepared control cells was extensively investigated. The three parts of control cells are pseudo-leukocyte and fixed platelets, which are fixed by glutaraldehyde, and control red cells from normal and thalassemic patients preserved and anticoagulated in CPD or CPDA-I. The Technicon H *1 system was based on the principle of light scattering but the Coulter MAXM was based on the principle of electrical impedance for cell counting and measurement. The self-prepared control cells can be satisfactorily utilized as control for each system with statistically significant difference (p < 0.05) for both systems. The expirated dates for control cells are different in both systems and should be determined for each system specifically. The control red cells prepared from thalassemic patients were quite satisfactorily useful as an abnormal control for both systems during this study. |
author2 |
Pramongkutklao Hospital |
author_facet |
Pramongkutklao Hospital Pasra Arnutti Ahnond Bunyaratavej Kovit Patanapanyasat Ampaiwan Chuansumrit |
format |
Article |
author |
Pasra Arnutti Ahnond Bunyaratavej Kovit Patanapanyasat Ampaiwan Chuansumrit |
author_sort |
Pasra Arnutti |
title |
Control Cells for Both Electrical Impedance and Light Scattering Automated Hematological Analyzers: Preparation from Normal and Thalassemic Blood Samples |
title_short |
Control Cells for Both Electrical Impedance and Light Scattering Automated Hematological Analyzers: Preparation from Normal and Thalassemic Blood Samples |
title_full |
Control Cells for Both Electrical Impedance and Light Scattering Automated Hematological Analyzers: Preparation from Normal and Thalassemic Blood Samples |
title_fullStr |
Control Cells for Both Electrical Impedance and Light Scattering Automated Hematological Analyzers: Preparation from Normal and Thalassemic Blood Samples |
title_full_unstemmed |
Control Cells for Both Electrical Impedance and Light Scattering Automated Hematological Analyzers: Preparation from Normal and Thalassemic Blood Samples |
title_sort |
control cells for both electrical impedance and light scattering automated hematological analyzers: preparation from normal and thalassemic blood samples |
publishDate |
2018 |
url |
https://repository.li.mahidol.ac.th/handle/123456789/18100 |
_version_ |
1763494676744110080 |