A comparison of erythema efficacy of ultraviolet B irradiation from Philips TL12 and TL01 lamps

The erythema efficacy of UVB irradiation from Philips TL12 and TL01 lamps has been evaluated and compared. Thirty-seven healthy Thai volunteers were irradiated on the previously unexposed lower back with TL12 and TL01 lamps in doses ranging 100 to 550 mJ/cm2and 360 to 2020 mJ/cm2, respectively. Eryt...

Full description

Saved in:
Bibliographic Details
Main Authors: V. Leenutaphong, S. Sudtim
Other Authors: Mahidol University
Format: Article
Published: 2018
Subjects:
Online Access:https://repository.li.mahidol.ac.th/handle/123456789/18404
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Mahidol University
id th-mahidol.18404
record_format dspace
spelling th-mahidol.184042018-07-04T15:17:12Z A comparison of erythema efficacy of ultraviolet B irradiation from Philips TL12 and TL01 lamps V. Leenutaphong S. Sudtim Mahidol University Faculty of Medicine, Siriraj Hospital, Mahidol University Immunology and Microbiology Medicine The erythema efficacy of UVB irradiation from Philips TL12 and TL01 lamps has been evaluated and compared. Thirty-seven healthy Thai volunteers were irradiated on the previously unexposed lower back with TL12 and TL01 lamps in doses ranging 100 to 550 mJ/cm2and 360 to 2020 mJ/cm2, respectively. Erythema was evaluated clinically and measured by a narrow- band spectrophotometer before exposure and 24 h after exposure. The threshold doses of UVB that induced barely perceptible erythema (MED(b)) with well- defined border erythema (MED(w)) and the steepness of the dose-response curves for erythema (DRAE) were compared. We found that MED(b) and MED(w) of the TL01 lamps were 4.19 and 4.52 times those of TL12 lamps, which were similar to those calculated from the CIE erythema action spectrum (4.2). However, the DRAE of the two lamps were quite similar. Because the initial dosage of UVB phototherapy is usually given as a percentage of a patient's MED, the initial exposure of TL01-UVB phototherapy should be about 4.2 times that of TL12-UVB. 2018-07-04T08:07:49Z 2018-07-04T08:07:49Z 1998-01-01 Article Photodermatology Photoimmunology and Photomedicine. Vol.14, No.3-4 (1998), 112-115 10.1111/j.1600-0781.1998.tb00023.x 09054383 2-s2.0-0031716134 https://repository.li.mahidol.ac.th/handle/123456789/18404 Mahidol University SCOPUS https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0031716134&origin=inward
institution Mahidol University
building Mahidol University Library
continent Asia
country Thailand
Thailand
content_provider Mahidol University Library
collection Mahidol University Institutional Repository
topic Immunology and Microbiology
Medicine
spellingShingle Immunology and Microbiology
Medicine
V. Leenutaphong
S. Sudtim
A comparison of erythema efficacy of ultraviolet B irradiation from Philips TL12 and TL01 lamps
description The erythema efficacy of UVB irradiation from Philips TL12 and TL01 lamps has been evaluated and compared. Thirty-seven healthy Thai volunteers were irradiated on the previously unexposed lower back with TL12 and TL01 lamps in doses ranging 100 to 550 mJ/cm2and 360 to 2020 mJ/cm2, respectively. Erythema was evaluated clinically and measured by a narrow- band spectrophotometer before exposure and 24 h after exposure. The threshold doses of UVB that induced barely perceptible erythema (MED(b)) with well- defined border erythema (MED(w)) and the steepness of the dose-response curves for erythema (DRAE) were compared. We found that MED(b) and MED(w) of the TL01 lamps were 4.19 and 4.52 times those of TL12 lamps, which were similar to those calculated from the CIE erythema action spectrum (4.2). However, the DRAE of the two lamps were quite similar. Because the initial dosage of UVB phototherapy is usually given as a percentage of a patient's MED, the initial exposure of TL01-UVB phototherapy should be about 4.2 times that of TL12-UVB.
author2 Mahidol University
author_facet Mahidol University
V. Leenutaphong
S. Sudtim
format Article
author V. Leenutaphong
S. Sudtim
author_sort V. Leenutaphong
title A comparison of erythema efficacy of ultraviolet B irradiation from Philips TL12 and TL01 lamps
title_short A comparison of erythema efficacy of ultraviolet B irradiation from Philips TL12 and TL01 lamps
title_full A comparison of erythema efficacy of ultraviolet B irradiation from Philips TL12 and TL01 lamps
title_fullStr A comparison of erythema efficacy of ultraviolet B irradiation from Philips TL12 and TL01 lamps
title_full_unstemmed A comparison of erythema efficacy of ultraviolet B irradiation from Philips TL12 and TL01 lamps
title_sort comparison of erythema efficacy of ultraviolet b irradiation from philips tl12 and tl01 lamps
publishDate 2018
url https://repository.li.mahidol.ac.th/handle/123456789/18404
_version_ 1763489562604077056