Breast pain and service satisfaction during digital mammography

Objectives: To determine the frequency and predisposing factors of breast pain felt during digital mammography, and factors associated with service satisfaction. Material and Method: A questionnaire was distributed to 1250 women immediately after their mammography. The outcomes assessed were a five-...

Full description

Saved in:
Bibliographic Details
Main Authors: Cholatip Wiratkapun, Panuwat Lertsithichai, Bussanee Wibulpolprasert, Montira Leelaswattanakul, Jantarika Detakarat, Pannee Jungjai
Other Authors: Mahidol University
Format: Article
Published: 2018
Subjects:
Online Access:https://repository.li.mahidol.ac.th/handle/123456789/23492
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Mahidol University
id th-mahidol.23492
record_format dspace
spelling th-mahidol.234922018-08-20T14:07:52Z Breast pain and service satisfaction during digital mammography Cholatip Wiratkapun Panuwat Lertsithichai Bussanee Wibulpolprasert Montira Leelaswattanakul Jantarika Detakarat Pannee Jungjai Mahidol University Medicine Objectives: To determine the frequency and predisposing factors of breast pain felt during digital mammography, and factors associated with service satisfaction. Material and Method: A questionnaire was distributed to 1250 women immediately after their mammography. The outcomes assessed were a five-point scale of breast pain and rating of the satisfaction with the mammography service. Several factors potentially associated with breast pain and satisfaction were obtained from the questionnaire and analyzed. Multiple cumulative logit regression was used to identify independent, significant factors. Results: Breast pain was found to be absent in 22% of patients, slight in 50%, moderate in 23% and substantial or severe in only 4%. Significant factors associated with breast pain during mammography included higher educational level, having no children, having had prior mammography, impolite and rough radiographer and poorly performed mammography. Factors associated with satisfaction with the mammography service included older age, polite and gentle radiographer and well-performed mammography. Conclusion: Radiographer delivery of the mammography service seemed to be the most important, modifiable reason for breast pain during mammography and dissatisfaction with the mammography service. 2018-08-20T07:07:52Z 2018-08-20T07:07:52Z 2006-11-01 Article Journal of the Medical Association of Thailand. Vol.89, No.11 (2006), 1864-1873 01252208 01252208 2-s2.0-33845510108 https://repository.li.mahidol.ac.th/handle/123456789/23492 Mahidol University SCOPUS https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33845510108&origin=inward
institution Mahidol University
building Mahidol University Library
continent Asia
country Thailand
Thailand
content_provider Mahidol University Library
collection Mahidol University Institutional Repository
topic Medicine
spellingShingle Medicine
Cholatip Wiratkapun
Panuwat Lertsithichai
Bussanee Wibulpolprasert
Montira Leelaswattanakul
Jantarika Detakarat
Pannee Jungjai
Breast pain and service satisfaction during digital mammography
description Objectives: To determine the frequency and predisposing factors of breast pain felt during digital mammography, and factors associated with service satisfaction. Material and Method: A questionnaire was distributed to 1250 women immediately after their mammography. The outcomes assessed were a five-point scale of breast pain and rating of the satisfaction with the mammography service. Several factors potentially associated with breast pain and satisfaction were obtained from the questionnaire and analyzed. Multiple cumulative logit regression was used to identify independent, significant factors. Results: Breast pain was found to be absent in 22% of patients, slight in 50%, moderate in 23% and substantial or severe in only 4%. Significant factors associated with breast pain during mammography included higher educational level, having no children, having had prior mammography, impolite and rough radiographer and poorly performed mammography. Factors associated with satisfaction with the mammography service included older age, polite and gentle radiographer and well-performed mammography. Conclusion: Radiographer delivery of the mammography service seemed to be the most important, modifiable reason for breast pain during mammography and dissatisfaction with the mammography service.
author2 Mahidol University
author_facet Mahidol University
Cholatip Wiratkapun
Panuwat Lertsithichai
Bussanee Wibulpolprasert
Montira Leelaswattanakul
Jantarika Detakarat
Pannee Jungjai
format Article
author Cholatip Wiratkapun
Panuwat Lertsithichai
Bussanee Wibulpolprasert
Montira Leelaswattanakul
Jantarika Detakarat
Pannee Jungjai
author_sort Cholatip Wiratkapun
title Breast pain and service satisfaction during digital mammography
title_short Breast pain and service satisfaction during digital mammography
title_full Breast pain and service satisfaction during digital mammography
title_fullStr Breast pain and service satisfaction during digital mammography
title_full_unstemmed Breast pain and service satisfaction during digital mammography
title_sort breast pain and service satisfaction during digital mammography
publishDate 2018
url https://repository.li.mahidol.ac.th/handle/123456789/23492
_version_ 1763491919383494656