Breast pain and service satisfaction during digital mammography
Objectives: To determine the frequency and predisposing factors of breast pain felt during digital mammography, and factors associated with service satisfaction. Material and Method: A questionnaire was distributed to 1250 women immediately after their mammography. The outcomes assessed were a five-...
Saved in:
Main Authors: | , , , , , |
---|---|
Other Authors: | |
Format: | Article |
Published: |
2018
|
Subjects: | |
Online Access: | https://repository.li.mahidol.ac.th/handle/123456789/23492 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Mahidol University |
id |
th-mahidol.23492 |
---|---|
record_format |
dspace |
spelling |
th-mahidol.234922018-08-20T14:07:52Z Breast pain and service satisfaction during digital mammography Cholatip Wiratkapun Panuwat Lertsithichai Bussanee Wibulpolprasert Montira Leelaswattanakul Jantarika Detakarat Pannee Jungjai Mahidol University Medicine Objectives: To determine the frequency and predisposing factors of breast pain felt during digital mammography, and factors associated with service satisfaction. Material and Method: A questionnaire was distributed to 1250 women immediately after their mammography. The outcomes assessed were a five-point scale of breast pain and rating of the satisfaction with the mammography service. Several factors potentially associated with breast pain and satisfaction were obtained from the questionnaire and analyzed. Multiple cumulative logit regression was used to identify independent, significant factors. Results: Breast pain was found to be absent in 22% of patients, slight in 50%, moderate in 23% and substantial or severe in only 4%. Significant factors associated with breast pain during mammography included higher educational level, having no children, having had prior mammography, impolite and rough radiographer and poorly performed mammography. Factors associated with satisfaction with the mammography service included older age, polite and gentle radiographer and well-performed mammography. Conclusion: Radiographer delivery of the mammography service seemed to be the most important, modifiable reason for breast pain during mammography and dissatisfaction with the mammography service. 2018-08-20T07:07:52Z 2018-08-20T07:07:52Z 2006-11-01 Article Journal of the Medical Association of Thailand. Vol.89, No.11 (2006), 1864-1873 01252208 01252208 2-s2.0-33845510108 https://repository.li.mahidol.ac.th/handle/123456789/23492 Mahidol University SCOPUS https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33845510108&origin=inward |
institution |
Mahidol University |
building |
Mahidol University Library |
continent |
Asia |
country |
Thailand Thailand |
content_provider |
Mahidol University Library |
collection |
Mahidol University Institutional Repository |
topic |
Medicine |
spellingShingle |
Medicine Cholatip Wiratkapun Panuwat Lertsithichai Bussanee Wibulpolprasert Montira Leelaswattanakul Jantarika Detakarat Pannee Jungjai Breast pain and service satisfaction during digital mammography |
description |
Objectives: To determine the frequency and predisposing factors of breast pain felt during digital mammography, and factors associated with service satisfaction. Material and Method: A questionnaire was distributed to 1250 women immediately after their mammography. The outcomes assessed were a five-point scale of breast pain and rating of the satisfaction with the mammography service. Several factors potentially associated with breast pain and satisfaction were obtained from the questionnaire and analyzed. Multiple cumulative logit regression was used to identify independent, significant factors. Results: Breast pain was found to be absent in 22% of patients, slight in 50%, moderate in 23% and substantial or severe in only 4%. Significant factors associated with breast pain during mammography included higher educational level, having no children, having had prior mammography, impolite and rough radiographer and poorly performed mammography. Factors associated with satisfaction with the mammography service included older age, polite and gentle radiographer and well-performed mammography. Conclusion: Radiographer delivery of the mammography service seemed to be the most important, modifiable reason for breast pain during mammography and dissatisfaction with the mammography service. |
author2 |
Mahidol University |
author_facet |
Mahidol University Cholatip Wiratkapun Panuwat Lertsithichai Bussanee Wibulpolprasert Montira Leelaswattanakul Jantarika Detakarat Pannee Jungjai |
format |
Article |
author |
Cholatip Wiratkapun Panuwat Lertsithichai Bussanee Wibulpolprasert Montira Leelaswattanakul Jantarika Detakarat Pannee Jungjai |
author_sort |
Cholatip Wiratkapun |
title |
Breast pain and service satisfaction during digital mammography |
title_short |
Breast pain and service satisfaction during digital mammography |
title_full |
Breast pain and service satisfaction during digital mammography |
title_fullStr |
Breast pain and service satisfaction during digital mammography |
title_full_unstemmed |
Breast pain and service satisfaction during digital mammography |
title_sort |
breast pain and service satisfaction during digital mammography |
publishDate |
2018 |
url |
https://repository.li.mahidol.ac.th/handle/123456789/23492 |
_version_ |
1763491919383494656 |