Evaluation of a sensitive/less-sensitive testing algorithm using the 3A11-LS assay for detecting recent HIV seroconversion among individuals with HIV-1 subtype B or E infection in Thailand

The development of a serologic algorithm to determine recent HIV seroconversion, using sensitive/less-sensitive testing strategies, has generated widespread interest in applying this approach to estimate HIV-1 incidence in various populations around the world. To evaluate this approach in non-B subt...

Full description

Saved in:
Bibliographic Details
Main Authors: B. S. Parekh, D. J. Hu, S. Vanichseni, G. A. Satten, D. Candal, N. L. Young, D. Kitayaporn, L. O. Srisuwanvilai, S. Rakhtam, R. Janssen, K. Choopanya, T. D. Mastro
Other Authors: National Center for Infectious Diseases
Format: Article
Published: 2018
Subjects:
Online Access:https://repository.li.mahidol.ac.th/handle/123456789/26569
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Mahidol University
id th-mahidol.26569
record_format dspace
spelling th-mahidol.265692018-09-07T16:49:16Z Evaluation of a sensitive/less-sensitive testing algorithm using the 3A11-LS assay for detecting recent HIV seroconversion among individuals with HIV-1 subtype B or E infection in Thailand B. S. Parekh D. J. Hu S. Vanichseni G. A. Satten D. Candal N. L. Young D. Kitayaporn L. O. Srisuwanvilai S. Rakhtam R. Janssen K. Choopanya T. D. Mastro National Center for Infectious Diseases Bangkok Metropolitan Administration HIV/AIDS Collaboration Mahidol University Immunology and Microbiology Medicine The development of a serologic algorithm to determine recent HIV seroconversion, using sensitive/less-sensitive testing strategies, has generated widespread interest in applying this approach to estimate HIV-1 incidence in various populations around the world. To evaluate this approach in non-B subtypes, longitudinal specimens (n = 522) collected from 90 incident infections among injecting drug users in Bangkok (subtype B infection, n = 18; subtype E infection, n = 72) were tested by the 3A11-LS assay. Standardized optical density (SOD) was calculated, using median values, and the window period between seroconversion as determined by sensitive and less sensitive tests was estimated by a maximum-likelihood model described previously. Our results show that the mean window period of the 3A11-LS assay was 155 days (95% CI, 128-189 days) for subtype B but was 270 days (95% CI, 187-349 days) for subtype E specimens from Thailand. About 4% of individuals with incident subtype E infections remained below the threshold (SOD of 0.75), even 2 years after seroconversion. Among the patients with clinical AIDS and declining antibodies, none of the 7 individuals with subtype B, but 10 (8.7%) of 115 with subtype E infections, were misclassified as recent infections. Lowering the cutoff to an SOD of 0.45 for subtype E specimens resulted in a mean window period of 185 days (95% CI, 154-211 days), with all individuals seroconverting, and reduced the number of subtype E-infected patients with AIDS who were misclassified as having recent infection to 2.6%. Our results demonstrate that the 3A11-LS assay has different performance characteristics in detecting recent infections among individuals infected with subtypes B or E. Determining appropriate cutoffs and mean window periods for other HIV-1 subtypes will be necessary before this approach can be reliably implemented in settings where non-B subtypes are common. 2018-09-07T09:41:48Z 2018-09-07T09:41:48Z 2001-04-02 Article AIDS Research and Human Retroviruses. Vol.17, No.5 (2001), 453-458 10.1089/088922201750102562 08892229 2-s2.0-0035794280 https://repository.li.mahidol.ac.th/handle/123456789/26569 Mahidol University SCOPUS https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0035794280&origin=inward
institution Mahidol University
building Mahidol University Library
continent Asia
country Thailand
Thailand
content_provider Mahidol University Library
collection Mahidol University Institutional Repository
topic Immunology and Microbiology
Medicine
spellingShingle Immunology and Microbiology
Medicine
B. S. Parekh
D. J. Hu
S. Vanichseni
G. A. Satten
D. Candal
N. L. Young
D. Kitayaporn
L. O. Srisuwanvilai
S. Rakhtam
R. Janssen
K. Choopanya
T. D. Mastro
Evaluation of a sensitive/less-sensitive testing algorithm using the 3A11-LS assay for detecting recent HIV seroconversion among individuals with HIV-1 subtype B or E infection in Thailand
description The development of a serologic algorithm to determine recent HIV seroconversion, using sensitive/less-sensitive testing strategies, has generated widespread interest in applying this approach to estimate HIV-1 incidence in various populations around the world. To evaluate this approach in non-B subtypes, longitudinal specimens (n = 522) collected from 90 incident infections among injecting drug users in Bangkok (subtype B infection, n = 18; subtype E infection, n = 72) were tested by the 3A11-LS assay. Standardized optical density (SOD) was calculated, using median values, and the window period between seroconversion as determined by sensitive and less sensitive tests was estimated by a maximum-likelihood model described previously. Our results show that the mean window period of the 3A11-LS assay was 155 days (95% CI, 128-189 days) for subtype B but was 270 days (95% CI, 187-349 days) for subtype E specimens from Thailand. About 4% of individuals with incident subtype E infections remained below the threshold (SOD of 0.75), even 2 years after seroconversion. Among the patients with clinical AIDS and declining antibodies, none of the 7 individuals with subtype B, but 10 (8.7%) of 115 with subtype E infections, were misclassified as recent infections. Lowering the cutoff to an SOD of 0.45 for subtype E specimens resulted in a mean window period of 185 days (95% CI, 154-211 days), with all individuals seroconverting, and reduced the number of subtype E-infected patients with AIDS who were misclassified as having recent infection to 2.6%. Our results demonstrate that the 3A11-LS assay has different performance characteristics in detecting recent infections among individuals infected with subtypes B or E. Determining appropriate cutoffs and mean window periods for other HIV-1 subtypes will be necessary before this approach can be reliably implemented in settings where non-B subtypes are common.
author2 National Center for Infectious Diseases
author_facet National Center for Infectious Diseases
B. S. Parekh
D. J. Hu
S. Vanichseni
G. A. Satten
D. Candal
N. L. Young
D. Kitayaporn
L. O. Srisuwanvilai
S. Rakhtam
R. Janssen
K. Choopanya
T. D. Mastro
format Article
author B. S. Parekh
D. J. Hu
S. Vanichseni
G. A. Satten
D. Candal
N. L. Young
D. Kitayaporn
L. O. Srisuwanvilai
S. Rakhtam
R. Janssen
K. Choopanya
T. D. Mastro
author_sort B. S. Parekh
title Evaluation of a sensitive/less-sensitive testing algorithm using the 3A11-LS assay for detecting recent HIV seroconversion among individuals with HIV-1 subtype B or E infection in Thailand
title_short Evaluation of a sensitive/less-sensitive testing algorithm using the 3A11-LS assay for detecting recent HIV seroconversion among individuals with HIV-1 subtype B or E infection in Thailand
title_full Evaluation of a sensitive/less-sensitive testing algorithm using the 3A11-LS assay for detecting recent HIV seroconversion among individuals with HIV-1 subtype B or E infection in Thailand
title_fullStr Evaluation of a sensitive/less-sensitive testing algorithm using the 3A11-LS assay for detecting recent HIV seroconversion among individuals with HIV-1 subtype B or E infection in Thailand
title_full_unstemmed Evaluation of a sensitive/less-sensitive testing algorithm using the 3A11-LS assay for detecting recent HIV seroconversion among individuals with HIV-1 subtype B or E infection in Thailand
title_sort evaluation of a sensitive/less-sensitive testing algorithm using the 3a11-ls assay for detecting recent hiv seroconversion among individuals with hiv-1 subtype b or e infection in thailand
publishDate 2018
url https://repository.li.mahidol.ac.th/handle/123456789/26569
_version_ 1763489606121029632