Use of spray-dried chitosan acetate and ethylcellulose as compression coats for colonic drug delivery: Effect of swelling on triggering in vitro drug release
Spray-dried chitosan acetate (CSA) and ethylcellulose (EC) were used as new compression coats for 5-aminosalicylic acid tablets. Constrained axial or radial swelling of pure CSA and EC/CSA tablets in 0.1 N HCl (stage I), Tris-HCl, pH 6.8 (stage II), and acetate buffer, pH 5.0 (stage III), was invest...
Saved in:
Main Authors: | , , , , , |
---|---|
Other Authors: | |
Format: | Article |
Published: |
2018
|
Subjects: | |
Online Access: | https://repository.li.mahidol.ac.th/handle/123456789/27285 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Mahidol University |
id |
th-mahidol.27285 |
---|---|
record_format |
dspace |
spelling |
th-mahidol.272852018-09-13T14:13:19Z Use of spray-dried chitosan acetate and ethylcellulose as compression coats for colonic drug delivery: Effect of swelling on triggering in vitro drug release J. Nunthanid M. Luangtana-anan P. Sriamornsak S. Limmatvapirat K. Huanbutta S. Puttipipatkhachorn Silpakorn University Mahidol University Biochemistry, Genetics and Molecular Biology Pharmacology, Toxicology and Pharmaceutics Spray-dried chitosan acetate (CSA) and ethylcellulose (EC) were used as new compression coats for 5-aminosalicylic acid tablets. Constrained axial or radial swelling of pure CSA and EC/CSA tablets in 0.1 N HCl (stage I), Tris-HCl, pH 6.8 (stage II), and acetate buffer, pH 5.0 (stage III), was investigated. Factors affecting in vitro drug release, i.e., % weight ratios of coating polymers, dip speeds of dissolution apparatus or pH of medium or colonic enzyme (β-glucosidase) in stage III, and use of a super disintegrant in core tablets, were evaluated. Swollen CSA gel dissolved at lower pH and became less soluble at higher pH. The mechanism of swelling was Fickian diffusion fitting well into both Higuchi's and Korsmeyer-Peppas models. EC:CSA, at 87.5:12.5% weight ratio, provided lag time rendering the tablets to reach stage III (simulated colonic fluid of patients), and the drug was released over 90% within 12 h. The system was a dual time- and pH-control due to the insolubility of EC suppressing water diffusion and the swelling of CSA in the stages I and II. The erosion of CSA gel in the stage III induced the disintegration of the coat resulting in rapid drug release. The lower dip speed and higher pH medium delayed the drug release, while a super disintegrant in the cores enhanced the drug release and no enzyme effect was observed. © 2008 Elsevier B.V. All rights reserved. 2018-09-13T06:26:56Z 2018-09-13T06:26:56Z 2009-02-01 Article European Journal of Pharmaceutics and Biopharmaceutics. Vol.71, No.2 (2009), 356-361 10.1016/j.ejpb.2008.08.002 09396411 2-s2.0-59649116615 https://repository.li.mahidol.ac.th/handle/123456789/27285 Mahidol University SCOPUS https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=59649116615&origin=inward |
institution |
Mahidol University |
building |
Mahidol University Library |
continent |
Asia |
country |
Thailand Thailand |
content_provider |
Mahidol University Library |
collection |
Mahidol University Institutional Repository |
topic |
Biochemistry, Genetics and Molecular Biology Pharmacology, Toxicology and Pharmaceutics |
spellingShingle |
Biochemistry, Genetics and Molecular Biology Pharmacology, Toxicology and Pharmaceutics J. Nunthanid M. Luangtana-anan P. Sriamornsak S. Limmatvapirat K. Huanbutta S. Puttipipatkhachorn Use of spray-dried chitosan acetate and ethylcellulose as compression coats for colonic drug delivery: Effect of swelling on triggering in vitro drug release |
description |
Spray-dried chitosan acetate (CSA) and ethylcellulose (EC) were used as new compression coats for 5-aminosalicylic acid tablets. Constrained axial or radial swelling of pure CSA and EC/CSA tablets in 0.1 N HCl (stage I), Tris-HCl, pH 6.8 (stage II), and acetate buffer, pH 5.0 (stage III), was investigated. Factors affecting in vitro drug release, i.e., % weight ratios of coating polymers, dip speeds of dissolution apparatus or pH of medium or colonic enzyme (β-glucosidase) in stage III, and use of a super disintegrant in core tablets, were evaluated. Swollen CSA gel dissolved at lower pH and became less soluble at higher pH. The mechanism of swelling was Fickian diffusion fitting well into both Higuchi's and Korsmeyer-Peppas models. EC:CSA, at 87.5:12.5% weight ratio, provided lag time rendering the tablets to reach stage III (simulated colonic fluid of patients), and the drug was released over 90% within 12 h. The system was a dual time- and pH-control due to the insolubility of EC suppressing water diffusion and the swelling of CSA in the stages I and II. The erosion of CSA gel in the stage III induced the disintegration of the coat resulting in rapid drug release. The lower dip speed and higher pH medium delayed the drug release, while a super disintegrant in the cores enhanced the drug release and no enzyme effect was observed. © 2008 Elsevier B.V. All rights reserved. |
author2 |
Silpakorn University |
author_facet |
Silpakorn University J. Nunthanid M. Luangtana-anan P. Sriamornsak S. Limmatvapirat K. Huanbutta S. Puttipipatkhachorn |
format |
Article |
author |
J. Nunthanid M. Luangtana-anan P. Sriamornsak S. Limmatvapirat K. Huanbutta S. Puttipipatkhachorn |
author_sort |
J. Nunthanid |
title |
Use of spray-dried chitosan acetate and ethylcellulose as compression coats for colonic drug delivery: Effect of swelling on triggering in vitro drug release |
title_short |
Use of spray-dried chitosan acetate and ethylcellulose as compression coats for colonic drug delivery: Effect of swelling on triggering in vitro drug release |
title_full |
Use of spray-dried chitosan acetate and ethylcellulose as compression coats for colonic drug delivery: Effect of swelling on triggering in vitro drug release |
title_fullStr |
Use of spray-dried chitosan acetate and ethylcellulose as compression coats for colonic drug delivery: Effect of swelling on triggering in vitro drug release |
title_full_unstemmed |
Use of spray-dried chitosan acetate and ethylcellulose as compression coats for colonic drug delivery: Effect of swelling on triggering in vitro drug release |
title_sort |
use of spray-dried chitosan acetate and ethylcellulose as compression coats for colonic drug delivery: effect of swelling on triggering in vitro drug release |
publishDate |
2018 |
url |
https://repository.li.mahidol.ac.th/handle/123456789/27285 |
_version_ |
1763491191685382144 |