Dried blood spots for the diagnosis and quantitation of HIV-1: Stability studies and evaluation of sensitivity and specificity for the diagnosis of infant HIV-1 infection in Thailand

Molecular methods for HIV-1 infection using dried blood-spot (DBS) for HIV-1 CRF01_AE subtypes have not been fully optimized. In this study assays for HIV-1 diagnosis or quantitation were evaluated using infant DBS from Thailand. Paired DBS and whole blood samples from 56 HIV-1 CRF01_AE or B'-i...

Full description

Saved in:
Bibliographic Details
Main Authors: W. Leelawiwat, N. L. Young, T. Chaowanachan, C. Y. Ou, M. Culnane, N. Vanprapa, N. Waranawat, P. Wasinrapee, P. A. Mock, J. Tappero, J. M. McNicholl
Other Authors: Thailand Ministry of Public Health
Format: Article
Published: 2018
Subjects:
Online Access:https://repository.li.mahidol.ac.th/handle/123456789/27738
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Mahidol University
id th-mahidol.27738
record_format dspace
spelling th-mahidol.277382018-09-13T13:44:27Z Dried blood spots for the diagnosis and quantitation of HIV-1: Stability studies and evaluation of sensitivity and specificity for the diagnosis of infant HIV-1 infection in Thailand W. Leelawiwat N. L. Young T. Chaowanachan C. Y. Ou M. Culnane N. Vanprapa N. Waranawat P. Wasinrapee P. A. Mock J. Tappero J. M. McNicholl Thailand Ministry of Public Health National Center for HIV/AIDS, Viral Hepatitis, STD, and TB Prevention Queen Sirikit National Institute of Child Health Mahidol University Immunology and Microbiology Molecular methods for HIV-1 infection using dried blood-spot (DBS) for HIV-1 CRF01_AE subtypes have not been fully optimized. In this study assays for HIV-1 diagnosis or quantitation were evaluated using infant DBS from Thailand. Paired DBS and whole blood samples from 56 HIV-1 CRF01_AE or B'-infected infants were tested for infant diagnosis using modified Amplicor DNA PCR and NucliSens RNA NASBA and an in-house real-time PCR assay. The Amplicor Monitor viral load (VL) assay, with modifications for DBS, was also evaluated. DBS VL were hematocrit corrected. Stability studies were done on DBS stored at -70 °C to 37 °C for up to 1 year. The DBS diagnostic assays were 96-100% sensitive and 100% specific for HIV-1 diagnosis. DBS HIV-1 VL were highly correlated with plasma VL when corrected using the actual or an assumed hematocrit factor (rc= 0.88 or 0.93, respectively). HIV-1 DNA in DBS appeared to be more stable than RNA and could be detected after up to 9 months at most temperatures. DBS VL could be consistently determined when stored frozen. These results show that DBS can be used accurately instead of whole blood for the diagnosis of HIV-1 infection and VL quantitation, particularly if samples are appropriately stored. © 2008 Elsevier B.V. 2018-09-13T06:44:27Z 2018-09-13T06:44:27Z 2009-02-01 Article Journal of Virological Methods. Vol.155, No.2 (2009), 109-117 10.1016/j.jviromet.2008.09.022 01660934 2-s2.0-57849104326 https://repository.li.mahidol.ac.th/handle/123456789/27738 Mahidol University SCOPUS https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=57849104326&origin=inward
institution Mahidol University
building Mahidol University Library
continent Asia
country Thailand
Thailand
content_provider Mahidol University Library
collection Mahidol University Institutional Repository
topic Immunology and Microbiology
spellingShingle Immunology and Microbiology
W. Leelawiwat
N. L. Young
T. Chaowanachan
C. Y. Ou
M. Culnane
N. Vanprapa
N. Waranawat
P. Wasinrapee
P. A. Mock
J. Tappero
J. M. McNicholl
Dried blood spots for the diagnosis and quantitation of HIV-1: Stability studies and evaluation of sensitivity and specificity for the diagnosis of infant HIV-1 infection in Thailand
description Molecular methods for HIV-1 infection using dried blood-spot (DBS) for HIV-1 CRF01_AE subtypes have not been fully optimized. In this study assays for HIV-1 diagnosis or quantitation were evaluated using infant DBS from Thailand. Paired DBS and whole blood samples from 56 HIV-1 CRF01_AE or B'-infected infants were tested for infant diagnosis using modified Amplicor DNA PCR and NucliSens RNA NASBA and an in-house real-time PCR assay. The Amplicor Monitor viral load (VL) assay, with modifications for DBS, was also evaluated. DBS VL were hematocrit corrected. Stability studies were done on DBS stored at -70 °C to 37 °C for up to 1 year. The DBS diagnostic assays were 96-100% sensitive and 100% specific for HIV-1 diagnosis. DBS HIV-1 VL were highly correlated with plasma VL when corrected using the actual or an assumed hematocrit factor (rc= 0.88 or 0.93, respectively). HIV-1 DNA in DBS appeared to be more stable than RNA and could be detected after up to 9 months at most temperatures. DBS VL could be consistently determined when stored frozen. These results show that DBS can be used accurately instead of whole blood for the diagnosis of HIV-1 infection and VL quantitation, particularly if samples are appropriately stored. © 2008 Elsevier B.V.
author2 Thailand Ministry of Public Health
author_facet Thailand Ministry of Public Health
W. Leelawiwat
N. L. Young
T. Chaowanachan
C. Y. Ou
M. Culnane
N. Vanprapa
N. Waranawat
P. Wasinrapee
P. A. Mock
J. Tappero
J. M. McNicholl
format Article
author W. Leelawiwat
N. L. Young
T. Chaowanachan
C. Y. Ou
M. Culnane
N. Vanprapa
N. Waranawat
P. Wasinrapee
P. A. Mock
J. Tappero
J. M. McNicholl
author_sort W. Leelawiwat
title Dried blood spots for the diagnosis and quantitation of HIV-1: Stability studies and evaluation of sensitivity and specificity for the diagnosis of infant HIV-1 infection in Thailand
title_short Dried blood spots for the diagnosis and quantitation of HIV-1: Stability studies and evaluation of sensitivity and specificity for the diagnosis of infant HIV-1 infection in Thailand
title_full Dried blood spots for the diagnosis and quantitation of HIV-1: Stability studies and evaluation of sensitivity and specificity for the diagnosis of infant HIV-1 infection in Thailand
title_fullStr Dried blood spots for the diagnosis and quantitation of HIV-1: Stability studies and evaluation of sensitivity and specificity for the diagnosis of infant HIV-1 infection in Thailand
title_full_unstemmed Dried blood spots for the diagnosis and quantitation of HIV-1: Stability studies and evaluation of sensitivity and specificity for the diagnosis of infant HIV-1 infection in Thailand
title_sort dried blood spots for the diagnosis and quantitation of hiv-1: stability studies and evaluation of sensitivity and specificity for the diagnosis of infant hiv-1 infection in thailand
publishDate 2018
url https://repository.li.mahidol.ac.th/handle/123456789/27738
_version_ 1763494034668519424