Wall thickness and outer diameter of the normal appendix in adults using 64 slices multidetector CT
Objective: Determine wall thickness and outer diameter of the normal appendix in adults using 64 slices multidetector CT Material and Method: A retrospective review of 538 patients (190 men, 348 women; mean age, 56.5 years + 15.2 SD) who were sent for abdomino-pelvic CT without clinical suspicion of...
Saved in:
Main Authors: | , , |
---|---|
Other Authors: | |
Format: | Article |
Published: |
2018
|
Subjects: | |
Online Access: | https://repository.li.mahidol.ac.th/handle/123456789/29371 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Mahidol University |
id |
th-mahidol.29371 |
---|---|
record_format |
dspace |
spelling |
th-mahidol.293712018-09-24T16:14:14Z Wall thickness and outer diameter of the normal appendix in adults using 64 slices multidetector CT Aphinya Charoensak Sopa Pongpornsup Wanwarang Suthikeeree Mahidol University Medicine Objective: Determine wall thickness and outer diameter of the normal appendix in adults using 64 slices multidetector CT Material and Method: A retrospective review of 538 patients (190 men, 348 women; mean age, 56.5 years + 15.2 SD) who were sent for abdomino-pelvic CT without clinical suspicion of acute appendicitis was conducted. Two radiologists blinded to the presented patient's history of appendectomy interpreted CT images regarding the visualization of the appendix, location, luminal contents and presence of appendicoliths. The maximum outer diameter and two walls thickness of the visualized appendices were measured. Results: The sensitivity, specificity, positive and negative predictive value, and accuracy for visualization of the appendix were 90.8%, 100%, 100%, 76.5% and 92.9% for reader 1 and 97.3%, 97.6%, 99.3%, 91.7% and 97.4% for reader 2. The mean maximum outer diameter of the appendix was 6.6 mm + 1.5 (range, 3.4-14.0 mm). The mean two walls thickness of the appendix was 4.4 mm + 1.0 (range, 1.6-8.0 mm). Conclusion: The normal appendix is frequently identified at 64 slices MDCT. Contrast to maximum outer diameter, normal two walls thickness of the appendix is infrequently exceeding the threshold of 6 mm. 2018-09-24T09:14:14Z 2018-09-24T09:14:14Z 2010-12-01 Article Journal of the Medical Association of Thailand. Vol.93, No.12 (2010), 1437-1442 01252208 01252208 2-s2.0-78650070610 https://repository.li.mahidol.ac.th/handle/123456789/29371 Mahidol University SCOPUS https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=78650070610&origin=inward |
institution |
Mahidol University |
building |
Mahidol University Library |
continent |
Asia |
country |
Thailand Thailand |
content_provider |
Mahidol University Library |
collection |
Mahidol University Institutional Repository |
topic |
Medicine |
spellingShingle |
Medicine Aphinya Charoensak Sopa Pongpornsup Wanwarang Suthikeeree Wall thickness and outer diameter of the normal appendix in adults using 64 slices multidetector CT |
description |
Objective: Determine wall thickness and outer diameter of the normal appendix in adults using 64 slices multidetector CT Material and Method: A retrospective review of 538 patients (190 men, 348 women; mean age, 56.5 years + 15.2 SD) who were sent for abdomino-pelvic CT without clinical suspicion of acute appendicitis was conducted. Two radiologists blinded to the presented patient's history of appendectomy interpreted CT images regarding the visualization of the appendix, location, luminal contents and presence of appendicoliths. The maximum outer diameter and two walls thickness of the visualized appendices were measured. Results: The sensitivity, specificity, positive and negative predictive value, and accuracy for visualization of the appendix were 90.8%, 100%, 100%, 76.5% and 92.9% for reader 1 and 97.3%, 97.6%, 99.3%, 91.7% and 97.4% for reader 2. The mean maximum outer diameter of the appendix was 6.6 mm + 1.5 (range, 3.4-14.0 mm). The mean two walls thickness of the appendix was 4.4 mm + 1.0 (range, 1.6-8.0 mm). Conclusion: The normal appendix is frequently identified at 64 slices MDCT. Contrast to maximum outer diameter, normal two walls thickness of the appendix is infrequently exceeding the threshold of 6 mm. |
author2 |
Mahidol University |
author_facet |
Mahidol University Aphinya Charoensak Sopa Pongpornsup Wanwarang Suthikeeree |
format |
Article |
author |
Aphinya Charoensak Sopa Pongpornsup Wanwarang Suthikeeree |
author_sort |
Aphinya Charoensak |
title |
Wall thickness and outer diameter of the normal appendix in adults using 64 slices multidetector CT |
title_short |
Wall thickness and outer diameter of the normal appendix in adults using 64 slices multidetector CT |
title_full |
Wall thickness and outer diameter of the normal appendix in adults using 64 slices multidetector CT |
title_fullStr |
Wall thickness and outer diameter of the normal appendix in adults using 64 slices multidetector CT |
title_full_unstemmed |
Wall thickness and outer diameter of the normal appendix in adults using 64 slices multidetector CT |
title_sort |
wall thickness and outer diameter of the normal appendix in adults using 64 slices multidetector ct |
publishDate |
2018 |
url |
https://repository.li.mahidol.ac.th/handle/123456789/29371 |
_version_ |
1763491141891653632 |