Development of a modified 100-gram oral glucose tolerance test for diagnosis of gestational diabetes mellitus and its diagnostic accuracy

Objective: To develop a modified 100-g oral glucose tolerance test (100-g OGTT) for the diagnosis of gestational diabetes mellitus (GDM) in order to reduce the number of values needed for the test. Materials and Methods: Patient charts of pregnant women who completed the 100-g OGTT test at the anten...

Full description

Saved in:
Bibliographic Details
Main Authors: Pornpimol Ruangvutilert, Piya Chaemsaithong, Kasem Ruangrongmorakot, Sujin Kanokpongsakdi, Prasert Sunsaneevithayakul
Other Authors: Mahidol University
Format: Article
Published: 2018
Subjects:
Online Access:https://repository.li.mahidol.ac.th/handle/123456789/29863
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Mahidol University
id th-mahidol.29863
record_format dspace
spelling th-mahidol.298632018-09-24T16:37:25Z Development of a modified 100-gram oral glucose tolerance test for diagnosis of gestational diabetes mellitus and its diagnostic accuracy Pornpimol Ruangvutilert Piya Chaemsaithong Kasem Ruangrongmorakot Sujin Kanokpongsakdi Prasert Sunsaneevithayakul Mahidol University Srinakharinwirot University Medicine Objective: To develop a modified 100-g oral glucose tolerance test (100-g OGTT) for the diagnosis of gestational diabetes mellitus (GDM) in order to reduce the number of values needed for the test. Materials and Methods: Patient charts of pregnant women who completed the 100-g OGTT test at the antenatal clinic, Siriraj Hospital between 2005 and 2006 were reviewed. Cases diagnosed with GDM using standard 100-g OGTT were selected. In non-GDM cases, the last 100-g OGTT test was selected. Diagnostic performances of each glucose value and two or three values in various combinations were determined. Results: One thousand seven hundred sixty three women completed GDM diagnosis throughout their pregnancy. Four hundred three women had GDM while 1,360 subjects were non-GDM. Considering single glucose values, the highest level of accuracy, and the best ROC curve were obtained from the value at 2 hours after glucose ingestion (2-h glucose value) with 93.00% accuracy and the area under the ROC curve of 0.961. The combination of 2-h glucose value with fasting plasma glucose (FPG) showed 93.25% accuracy. FPG combined with 1-h and 2-h glucose values achieved 100% sensitivity with 92% accuracy. Conclusion: FPG in combined with 1-h and 2-h glucose values is an interesting alternative for the diagnosis of GDM. 2018-09-24T09:37:25Z 2018-09-24T09:37:25Z 2010-01-01 Article Journal of the Medical Association of Thailand. Vol.93, No.10 (2010), 1121-1127 01252208 01252208 2-s2.0-77958112410 https://repository.li.mahidol.ac.th/handle/123456789/29863 Mahidol University SCOPUS https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77958112410&origin=inward
institution Mahidol University
building Mahidol University Library
continent Asia
country Thailand
Thailand
content_provider Mahidol University Library
collection Mahidol University Institutional Repository
topic Medicine
spellingShingle Medicine
Pornpimol Ruangvutilert
Piya Chaemsaithong
Kasem Ruangrongmorakot
Sujin Kanokpongsakdi
Prasert Sunsaneevithayakul
Development of a modified 100-gram oral glucose tolerance test for diagnosis of gestational diabetes mellitus and its diagnostic accuracy
description Objective: To develop a modified 100-g oral glucose tolerance test (100-g OGTT) for the diagnosis of gestational diabetes mellitus (GDM) in order to reduce the number of values needed for the test. Materials and Methods: Patient charts of pregnant women who completed the 100-g OGTT test at the antenatal clinic, Siriraj Hospital between 2005 and 2006 were reviewed. Cases diagnosed with GDM using standard 100-g OGTT were selected. In non-GDM cases, the last 100-g OGTT test was selected. Diagnostic performances of each glucose value and two or three values in various combinations were determined. Results: One thousand seven hundred sixty three women completed GDM diagnosis throughout their pregnancy. Four hundred three women had GDM while 1,360 subjects were non-GDM. Considering single glucose values, the highest level of accuracy, and the best ROC curve were obtained from the value at 2 hours after glucose ingestion (2-h glucose value) with 93.00% accuracy and the area under the ROC curve of 0.961. The combination of 2-h glucose value with fasting plasma glucose (FPG) showed 93.25% accuracy. FPG combined with 1-h and 2-h glucose values achieved 100% sensitivity with 92% accuracy. Conclusion: FPG in combined with 1-h and 2-h glucose values is an interesting alternative for the diagnosis of GDM.
author2 Mahidol University
author_facet Mahidol University
Pornpimol Ruangvutilert
Piya Chaemsaithong
Kasem Ruangrongmorakot
Sujin Kanokpongsakdi
Prasert Sunsaneevithayakul
format Article
author Pornpimol Ruangvutilert
Piya Chaemsaithong
Kasem Ruangrongmorakot
Sujin Kanokpongsakdi
Prasert Sunsaneevithayakul
author_sort Pornpimol Ruangvutilert
title Development of a modified 100-gram oral glucose tolerance test for diagnosis of gestational diabetes mellitus and its diagnostic accuracy
title_short Development of a modified 100-gram oral glucose tolerance test for diagnosis of gestational diabetes mellitus and its diagnostic accuracy
title_full Development of a modified 100-gram oral glucose tolerance test for diagnosis of gestational diabetes mellitus and its diagnostic accuracy
title_fullStr Development of a modified 100-gram oral glucose tolerance test for diagnosis of gestational diabetes mellitus and its diagnostic accuracy
title_full_unstemmed Development of a modified 100-gram oral glucose tolerance test for diagnosis of gestational diabetes mellitus and its diagnostic accuracy
title_sort development of a modified 100-gram oral glucose tolerance test for diagnosis of gestational diabetes mellitus and its diagnostic accuracy
publishDate 2018
url https://repository.li.mahidol.ac.th/handle/123456789/29863
_version_ 1763495100657172480