Development of a modified 100-gram oral glucose tolerance test for diagnosis of gestational diabetes mellitus and its diagnostic accuracy
Objective: To develop a modified 100-g oral glucose tolerance test (100-g OGTT) for the diagnosis of gestational diabetes mellitus (GDM) in order to reduce the number of values needed for the test. Materials and Methods: Patient charts of pregnant women who completed the 100-g OGTT test at the anten...
Saved in:
Main Authors: | , , , , |
---|---|
Other Authors: | |
Format: | Article |
Published: |
2018
|
Subjects: | |
Online Access: | https://repository.li.mahidol.ac.th/handle/123456789/29863 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Mahidol University |
id |
th-mahidol.29863 |
---|---|
record_format |
dspace |
spelling |
th-mahidol.298632018-09-24T16:37:25Z Development of a modified 100-gram oral glucose tolerance test for diagnosis of gestational diabetes mellitus and its diagnostic accuracy Pornpimol Ruangvutilert Piya Chaemsaithong Kasem Ruangrongmorakot Sujin Kanokpongsakdi Prasert Sunsaneevithayakul Mahidol University Srinakharinwirot University Medicine Objective: To develop a modified 100-g oral glucose tolerance test (100-g OGTT) for the diagnosis of gestational diabetes mellitus (GDM) in order to reduce the number of values needed for the test. Materials and Methods: Patient charts of pregnant women who completed the 100-g OGTT test at the antenatal clinic, Siriraj Hospital between 2005 and 2006 were reviewed. Cases diagnosed with GDM using standard 100-g OGTT were selected. In non-GDM cases, the last 100-g OGTT test was selected. Diagnostic performances of each glucose value and two or three values in various combinations were determined. Results: One thousand seven hundred sixty three women completed GDM diagnosis throughout their pregnancy. Four hundred three women had GDM while 1,360 subjects were non-GDM. Considering single glucose values, the highest level of accuracy, and the best ROC curve were obtained from the value at 2 hours after glucose ingestion (2-h glucose value) with 93.00% accuracy and the area under the ROC curve of 0.961. The combination of 2-h glucose value with fasting plasma glucose (FPG) showed 93.25% accuracy. FPG combined with 1-h and 2-h glucose values achieved 100% sensitivity with 92% accuracy. Conclusion: FPG in combined with 1-h and 2-h glucose values is an interesting alternative for the diagnosis of GDM. 2018-09-24T09:37:25Z 2018-09-24T09:37:25Z 2010-01-01 Article Journal of the Medical Association of Thailand. Vol.93, No.10 (2010), 1121-1127 01252208 01252208 2-s2.0-77958112410 https://repository.li.mahidol.ac.th/handle/123456789/29863 Mahidol University SCOPUS https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77958112410&origin=inward |
institution |
Mahidol University |
building |
Mahidol University Library |
continent |
Asia |
country |
Thailand Thailand |
content_provider |
Mahidol University Library |
collection |
Mahidol University Institutional Repository |
topic |
Medicine |
spellingShingle |
Medicine Pornpimol Ruangvutilert Piya Chaemsaithong Kasem Ruangrongmorakot Sujin Kanokpongsakdi Prasert Sunsaneevithayakul Development of a modified 100-gram oral glucose tolerance test for diagnosis of gestational diabetes mellitus and its diagnostic accuracy |
description |
Objective: To develop a modified 100-g oral glucose tolerance test (100-g OGTT) for the diagnosis of gestational diabetes mellitus (GDM) in order to reduce the number of values needed for the test. Materials and Methods: Patient charts of pregnant women who completed the 100-g OGTT test at the antenatal clinic, Siriraj Hospital between 2005 and 2006 were reviewed. Cases diagnosed with GDM using standard 100-g OGTT were selected. In non-GDM cases, the last 100-g OGTT test was selected. Diagnostic performances of each glucose value and two or three values in various combinations were determined. Results: One thousand seven hundred sixty three women completed GDM diagnosis throughout their pregnancy. Four hundred three women had GDM while 1,360 subjects were non-GDM. Considering single glucose values, the highest level of accuracy, and the best ROC curve were obtained from the value at 2 hours after glucose ingestion (2-h glucose value) with 93.00% accuracy and the area under the ROC curve of 0.961. The combination of 2-h glucose value with fasting plasma glucose (FPG) showed 93.25% accuracy. FPG combined with 1-h and 2-h glucose values achieved 100% sensitivity with 92% accuracy. Conclusion: FPG in combined with 1-h and 2-h glucose values is an interesting alternative for the diagnosis of GDM. |
author2 |
Mahidol University |
author_facet |
Mahidol University Pornpimol Ruangvutilert Piya Chaemsaithong Kasem Ruangrongmorakot Sujin Kanokpongsakdi Prasert Sunsaneevithayakul |
format |
Article |
author |
Pornpimol Ruangvutilert Piya Chaemsaithong Kasem Ruangrongmorakot Sujin Kanokpongsakdi Prasert Sunsaneevithayakul |
author_sort |
Pornpimol Ruangvutilert |
title |
Development of a modified 100-gram oral glucose tolerance test for diagnosis of gestational diabetes mellitus and its diagnostic accuracy |
title_short |
Development of a modified 100-gram oral glucose tolerance test for diagnosis of gestational diabetes mellitus and its diagnostic accuracy |
title_full |
Development of a modified 100-gram oral glucose tolerance test for diagnosis of gestational diabetes mellitus and its diagnostic accuracy |
title_fullStr |
Development of a modified 100-gram oral glucose tolerance test for diagnosis of gestational diabetes mellitus and its diagnostic accuracy |
title_full_unstemmed |
Development of a modified 100-gram oral glucose tolerance test for diagnosis of gestational diabetes mellitus and its diagnostic accuracy |
title_sort |
development of a modified 100-gram oral glucose tolerance test for diagnosis of gestational diabetes mellitus and its diagnostic accuracy |
publishDate |
2018 |
url |
https://repository.li.mahidol.ac.th/handle/123456789/29863 |
_version_ |
1763495100657172480 |