Diagnosis of bowel obstruction: added value of multiplanar reformations from multidetector CT in comparison with axial planes alone.

To retrospectively assess the benefit of multiplanar reformations from multidetector CT for diagnosis of bowel obstruction in comparison with axial planes alone. Between October 2008 and May 2010, included the consecutive 75 patients/76 CT studies who underwent multidetector CT at Siriraj Hospital t...

Full description

Saved in:
Bibliographic Details
Main Authors: Shanigarn Keoplung, Wanwarang Teerasamit, Voraparee Suvannarerg
Other Authors: Mahidol University
Format: Article
Published: 2018
Subjects:
Online Access:https://repository.li.mahidol.ac.th/handle/123456789/32602
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Mahidol University
id th-mahidol.32602
record_format dspace
spelling th-mahidol.326022018-10-19T12:35:50Z Diagnosis of bowel obstruction: added value of multiplanar reformations from multidetector CT in comparison with axial planes alone. Shanigarn Keoplung Wanwarang Teerasamit Voraparee Suvannarerg Mahidol University Medicine To retrospectively assess the benefit of multiplanar reformations from multidetector CT for diagnosis of bowel obstruction in comparison with axial planes alone. Between October 2008 and May 2010, included the consecutive 75 patients/76 CT studies who underwent multidetector CT at Siriraj Hospital to rule out bowel obstruction. Fifty-seven patients of 58 studies confirmed the final diagnosis of bowel obstruction by surgical proof or obstructive symptoms relief from conservative treatments; divided into 25 small bowel and 33 large bowel obstructions. Two independent readers, blinded to diagnosis, interpreted for bowel obstruction firstly using axial slices alone, then immediately scoring MPR images including axial, coronal, sagittal, and oblique reformations from the same study. Confidence score was applied In case of radiological diagnosis of bowel obstruction, the findings of transition point, cause, severity, and complication were also evaluated. CT diagnosis of bowel obstruction was made 54 on axial image alones and 55 on axial image plus MPR, leading to the sensitivity of 93.1% and specificity of 77.8% on the axial scans alone and the sensitivity of 94.8% and specificity of 72.2% on the axial plus MPR, respectively. The axial plus MPR images helped correct diagnosis and increased confidence score in one case of low grade, small bowel obstruction. Accuracy in diagnosis of between large bowel obstruction and small bowel obstruction was 90% and 88.5% on axial scans alone and 90% and 92.3% on axial plus MPR scans, respectively. The axial scan CT is an appropriate modality for the patients suspected bowel obstruction. The authors encourage using MPR as the adjunct tool to the axial images, especially in the case suspected small bowel obstruction. MPR help increasing diagnostic confidence and confirming the findings found on axial image. 2018-10-19T05:35:50Z 2018-10-19T05:35:50Z 2013-01-01 Article Journal of the Medical Association of Thailand = Chotmaihet thangphaet. Vol.96, No.12 (2013), 1569-1577 01252208 2-s2.0-84897570703 https://repository.li.mahidol.ac.th/handle/123456789/32602 Mahidol University SCOPUS https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84897570703&origin=inward
institution Mahidol University
building Mahidol University Library
continent Asia
country Thailand
Thailand
content_provider Mahidol University Library
collection Mahidol University Institutional Repository
topic Medicine
spellingShingle Medicine
Shanigarn Keoplung
Wanwarang Teerasamit
Voraparee Suvannarerg
Diagnosis of bowel obstruction: added value of multiplanar reformations from multidetector CT in comparison with axial planes alone.
description To retrospectively assess the benefit of multiplanar reformations from multidetector CT for diagnosis of bowel obstruction in comparison with axial planes alone. Between October 2008 and May 2010, included the consecutive 75 patients/76 CT studies who underwent multidetector CT at Siriraj Hospital to rule out bowel obstruction. Fifty-seven patients of 58 studies confirmed the final diagnosis of bowel obstruction by surgical proof or obstructive symptoms relief from conservative treatments; divided into 25 small bowel and 33 large bowel obstructions. Two independent readers, blinded to diagnosis, interpreted for bowel obstruction firstly using axial slices alone, then immediately scoring MPR images including axial, coronal, sagittal, and oblique reformations from the same study. Confidence score was applied In case of radiological diagnosis of bowel obstruction, the findings of transition point, cause, severity, and complication were also evaluated. CT diagnosis of bowel obstruction was made 54 on axial image alones and 55 on axial image plus MPR, leading to the sensitivity of 93.1% and specificity of 77.8% on the axial scans alone and the sensitivity of 94.8% and specificity of 72.2% on the axial plus MPR, respectively. The axial plus MPR images helped correct diagnosis and increased confidence score in one case of low grade, small bowel obstruction. Accuracy in diagnosis of between large bowel obstruction and small bowel obstruction was 90% and 88.5% on axial scans alone and 90% and 92.3% on axial plus MPR scans, respectively. The axial scan CT is an appropriate modality for the patients suspected bowel obstruction. The authors encourage using MPR as the adjunct tool to the axial images, especially in the case suspected small bowel obstruction. MPR help increasing diagnostic confidence and confirming the findings found on axial image.
author2 Mahidol University
author_facet Mahidol University
Shanigarn Keoplung
Wanwarang Teerasamit
Voraparee Suvannarerg
format Article
author Shanigarn Keoplung
Wanwarang Teerasamit
Voraparee Suvannarerg
author_sort Shanigarn Keoplung
title Diagnosis of bowel obstruction: added value of multiplanar reformations from multidetector CT in comparison with axial planes alone.
title_short Diagnosis of bowel obstruction: added value of multiplanar reformations from multidetector CT in comparison with axial planes alone.
title_full Diagnosis of bowel obstruction: added value of multiplanar reformations from multidetector CT in comparison with axial planes alone.
title_fullStr Diagnosis of bowel obstruction: added value of multiplanar reformations from multidetector CT in comparison with axial planes alone.
title_full_unstemmed Diagnosis of bowel obstruction: added value of multiplanar reformations from multidetector CT in comparison with axial planes alone.
title_sort diagnosis of bowel obstruction: added value of multiplanar reformations from multidetector ct in comparison with axial planes alone.
publishDate 2018
url https://repository.li.mahidol.ac.th/handle/123456789/32602
_version_ 1763491252305657856