Measurement and analysis system of the knee joint motion in gait evaluation for rehabilitation medicine

The purpose of this study is to create a device for measuring the knee joint motion during walking. Knee joint motion is one of the significant clinical parameters for assessing people who have difficulties in walking. Since commercial gait goniometers are very expensive and there are durability pro...

Full description

Saved in:
Bibliographic Details
Main Author: Neramitr Chirakanphaisarn
Other Authors: Mahidol University
Format: Conference or Workshop Item
Published: 2018
Subjects:
Online Access:https://repository.li.mahidol.ac.th/handle/123456789/33688
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Mahidol University
id th-mahidol.33688
record_format dspace
spelling th-mahidol.336882018-11-09T09:09:37Z Measurement and analysis system of the knee joint motion in gait evaluation for rehabilitation medicine Neramitr Chirakanphaisarn Mahidol University Computer Science The purpose of this study is to create a device for measuring the knee joint motion during walking. Knee joint motion is one of the significant clinical parameters for assessing people who have difficulties in walking. Since commercial gait goniometers are very expensive and there are durability problems, the goal of this study was to construct a prototype of dynamic knee joint measuring equipment which is inexpensive, efficient, portable, and durable. The equipment can measure the angles of the knee joint motion in real time, and can record the measured values in an SD card immediately. Moreover, gait parameters can be analyzed. The subjects of the experiments are twenty normal people and twenty less disabled people at Ramathibodi hospital, Thailand. The results are compared with those measured by the commercial Ultra-Flex [8] for forty subjects while they walked at the comfortable speed. It was shown that both gave closely correlated graphs. Also, the experiments measured the knee joint motion using the prototype for the subjects before rehab, and after 3-month rehab. The results revealed that the walking signals of the subjects did improve. They also indicated that the knee joint angles of the subjects are close to the normal knee control after treatment. © 2014 IEEE. 2018-11-09T02:09:37Z 2018-11-09T02:09:37Z 2014-01-01 Conference Paper 2014 4th International Conference on Digital Information and Communication Technology and Its Applications, DICTAP 2014. (2014), 315-320 10.1109/DICTAP.2014.6821703 2-s2.0-84902595386 https://repository.li.mahidol.ac.th/handle/123456789/33688 Mahidol University SCOPUS https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84902595386&origin=inward
institution Mahidol University
building Mahidol University Library
continent Asia
country Thailand
Thailand
content_provider Mahidol University Library
collection Mahidol University Institutional Repository
topic Computer Science
spellingShingle Computer Science
Neramitr Chirakanphaisarn
Measurement and analysis system of the knee joint motion in gait evaluation for rehabilitation medicine
description The purpose of this study is to create a device for measuring the knee joint motion during walking. Knee joint motion is one of the significant clinical parameters for assessing people who have difficulties in walking. Since commercial gait goniometers are very expensive and there are durability problems, the goal of this study was to construct a prototype of dynamic knee joint measuring equipment which is inexpensive, efficient, portable, and durable. The equipment can measure the angles of the knee joint motion in real time, and can record the measured values in an SD card immediately. Moreover, gait parameters can be analyzed. The subjects of the experiments are twenty normal people and twenty less disabled people at Ramathibodi hospital, Thailand. The results are compared with those measured by the commercial Ultra-Flex [8] for forty subjects while they walked at the comfortable speed. It was shown that both gave closely correlated graphs. Also, the experiments measured the knee joint motion using the prototype for the subjects before rehab, and after 3-month rehab. The results revealed that the walking signals of the subjects did improve. They also indicated that the knee joint angles of the subjects are close to the normal knee control after treatment. © 2014 IEEE.
author2 Mahidol University
author_facet Mahidol University
Neramitr Chirakanphaisarn
format Conference or Workshop Item
author Neramitr Chirakanphaisarn
author_sort Neramitr Chirakanphaisarn
title Measurement and analysis system of the knee joint motion in gait evaluation for rehabilitation medicine
title_short Measurement and analysis system of the knee joint motion in gait evaluation for rehabilitation medicine
title_full Measurement and analysis system of the knee joint motion in gait evaluation for rehabilitation medicine
title_fullStr Measurement and analysis system of the knee joint motion in gait evaluation for rehabilitation medicine
title_full_unstemmed Measurement and analysis system of the knee joint motion in gait evaluation for rehabilitation medicine
title_sort measurement and analysis system of the knee joint motion in gait evaluation for rehabilitation medicine
publishDate 2018
url https://repository.li.mahidol.ac.th/handle/123456789/33688
_version_ 1763496137598173184