Clinical comparison of a new swept-source optical coherence tomography-based optical biometer and a time-domain optical coherence tomography-based optical biometer

© 2015 The Authors. Purpose To evaluate the repeatability and reproducibility of a newer swept-source optical biometer and to compare it with a standard partial coherence interferometry (PCI) biometer. Setting Siriraj Hospital, Mahidol University, Bangkok, Thailand. Design Prospective comparative st...

Full description

Saved in:
Bibliographic Details
Main Authors: Sabong Srivannaboon, Chareenun Chirapapaisan, Pratuangsri Chonpimai, Siriwan Loket
Other Authors: Mahidol University
Format: Article
Published: 2018
Subjects:
Online Access:https://repository.li.mahidol.ac.th/handle/123456789/36301
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Mahidol University
id th-mahidol.36301
record_format dspace
spelling th-mahidol.363012018-11-23T17:34:19Z Clinical comparison of a new swept-source optical coherence tomography-based optical biometer and a time-domain optical coherence tomography-based optical biometer Sabong Srivannaboon Chareenun Chirapapaisan Pratuangsri Chonpimai Siriwan Loket Mahidol University Medicine © 2015 The Authors. Purpose To evaluate the repeatability and reproducibility of a newer swept-source optical biometer and to compare it with a standard partial coherence interferometry (PCI) biometer. Setting Siriraj Hospital, Mahidol University, Bangkok, Thailand. Design Prospective comparative study. Methods One hundred eyes from 100 cataract patients were enrolled in this study. Each patient was measured with 2 optical biometers, a newer swept-source optical biometer (IOLMaster 700) and a standard partial coherence interferometry biometer (IOLMaster 500) by 2 independent operators. The keratometry, axial length (AL), anterior chamber depth, white-to-white corneal diameter, and intraocular lens (IOL) power, calculated by the SRK/T and the Haigis formulas for each device, were recorded. Intraoperator repeatability and interoperator reproducibility of both devices were analyzed using intraclass correlation coefficients (ICCs). Agreement of ocular biometry and IOL power between the 2 devices was evaluated using the Bland-Altman method. Results The repeatability and reproducibility of the swept-source and standard biometers were high for all ocular biometry parameters (ICC, 0.93-1.00). The agreement between the 2 biometers was also high (ICC, 0.92-1.00). The IOL powers obtained from both devices were not distinct. Because of the density of the cataracts, the AL in 5 eyes could be measured only by the swept-source biometer. Conclusions Repeatability and reproducibility of a swept-source optical biometer was excellent and agreement with a standard biometer was very high. Better lens penetration ability and AL measurements were obtained with the swept-source biometer than with the standard biometer. Financial Disclosure No author has a financial or proprietary interest in any material or method mentioned. 2018-11-23T10:34:19Z 2018-11-23T10:34:19Z 2015-10-01 Article Journal of Cataract and Refractive Surgery. Vol.41, No.10 (2015), 2224-2232 10.1016/j.jcrs.2015.03.019 18734502 08863350 2-s2.0-84952331108 https://repository.li.mahidol.ac.th/handle/123456789/36301 Mahidol University SCOPUS https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84952331108&origin=inward
institution Mahidol University
building Mahidol University Library
continent Asia
country Thailand
Thailand
content_provider Mahidol University Library
collection Mahidol University Institutional Repository
topic Medicine
spellingShingle Medicine
Sabong Srivannaboon
Chareenun Chirapapaisan
Pratuangsri Chonpimai
Siriwan Loket
Clinical comparison of a new swept-source optical coherence tomography-based optical biometer and a time-domain optical coherence tomography-based optical biometer
description © 2015 The Authors. Purpose To evaluate the repeatability and reproducibility of a newer swept-source optical biometer and to compare it with a standard partial coherence interferometry (PCI) biometer. Setting Siriraj Hospital, Mahidol University, Bangkok, Thailand. Design Prospective comparative study. Methods One hundred eyes from 100 cataract patients were enrolled in this study. Each patient was measured with 2 optical biometers, a newer swept-source optical biometer (IOLMaster 700) and a standard partial coherence interferometry biometer (IOLMaster 500) by 2 independent operators. The keratometry, axial length (AL), anterior chamber depth, white-to-white corneal diameter, and intraocular lens (IOL) power, calculated by the SRK/T and the Haigis formulas for each device, were recorded. Intraoperator repeatability and interoperator reproducibility of both devices were analyzed using intraclass correlation coefficients (ICCs). Agreement of ocular biometry and IOL power between the 2 devices was evaluated using the Bland-Altman method. Results The repeatability and reproducibility of the swept-source and standard biometers were high for all ocular biometry parameters (ICC, 0.93-1.00). The agreement between the 2 biometers was also high (ICC, 0.92-1.00). The IOL powers obtained from both devices were not distinct. Because of the density of the cataracts, the AL in 5 eyes could be measured only by the swept-source biometer. Conclusions Repeatability and reproducibility of a swept-source optical biometer was excellent and agreement with a standard biometer was very high. Better lens penetration ability and AL measurements were obtained with the swept-source biometer than with the standard biometer. Financial Disclosure No author has a financial or proprietary interest in any material or method mentioned.
author2 Mahidol University
author_facet Mahidol University
Sabong Srivannaboon
Chareenun Chirapapaisan
Pratuangsri Chonpimai
Siriwan Loket
format Article
author Sabong Srivannaboon
Chareenun Chirapapaisan
Pratuangsri Chonpimai
Siriwan Loket
author_sort Sabong Srivannaboon
title Clinical comparison of a new swept-source optical coherence tomography-based optical biometer and a time-domain optical coherence tomography-based optical biometer
title_short Clinical comparison of a new swept-source optical coherence tomography-based optical biometer and a time-domain optical coherence tomography-based optical biometer
title_full Clinical comparison of a new swept-source optical coherence tomography-based optical biometer and a time-domain optical coherence tomography-based optical biometer
title_fullStr Clinical comparison of a new swept-source optical coherence tomography-based optical biometer and a time-domain optical coherence tomography-based optical biometer
title_full_unstemmed Clinical comparison of a new swept-source optical coherence tomography-based optical biometer and a time-domain optical coherence tomography-based optical biometer
title_sort clinical comparison of a new swept-source optical coherence tomography-based optical biometer and a time-domain optical coherence tomography-based optical biometer
publishDate 2018
url https://repository.li.mahidol.ac.th/handle/123456789/36301
_version_ 1763489003650154496